AED-delivery Using Drones in Out-of-hospital Cardiac Arrest

NCT ID: NCT04415398

Last Updated: 2020-10-05

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

12 participants

Study Classification

INTERVENTIONAL

Study Start Date

2020-06-01

Study Completion Date

2020-09-30

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Time to defibrillation is the most important predictor of survival in cardiac arrest. Traditional emergency medical system response is often to slow. The aim of this study is to investigate the feasibility of drone systems that delivers Automated External Defibrillators (AED) to the scene of suspected Out-of-Hospital Cardiac Arrests (OHCA).

This study will test the feasibility of real-life flights with drones carrying automated external defibrillators (AEDs) to out-of-hospital cardiac arrest (OHCA) as a complement to standard care i.e EMS

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

We will test the feasibility of dispatching an out of sight AED-drone system to real-life OHCA in parallel with standard EMS dispatch. The study period is 5 months between May to September 2020. The study area will be covered by three individual drone systems covering some 80,000 inhabitants within the controlled airspace of Säve airport in Göteborg Sweden. Each drone system will have a flight range of six km.

The first month of the study period will be used as run-in period and the drone systems are dispatched for beyond visual line of sight (BVLOS) flights in a simulated fashion and optimized to decrease delays and to log pre-specified system variables, adherence to protocol, time delays, technological functionality, weather conditions, conflict in the airspace.

During the following 4 months June-September 2020, drones will dispatched to real-life suspected OHCA during daytime 08:00-22:00.

An EMS communication radio-unit is placed at the drone control center. In case of a suspected OHCA in the service area and will be alerted by the dispatch centre (SOS alarm) when a suspected OHCA is recognized during the 112-call.

* The dispatcher identifies a cardiac arrest in the service areas
* A pilot (from Everdrone) immediately initiates deployment protocol for the drone.
* Parallel communication is made with the air traffic control (ATC) centre in order to grant permit to deploy the drone with regards to the current weather and aviation situation.
* The drone then flies to the coordinates of the OHCA and delivers an AED at the scene using a winch system
* The AED may be attached to the patient by the bystander on scene

Development of the technology is made by Everdrone AB Göteborg and SOS Alarm AB (national dispatch organisation) and parallel applications for certificates for the individual aircraft and permits for beyond visual line of sight flights (BVLOS-flights) was granted by the Swedish Transportation board on 27 April 2020.

The drone system is operated only during daytime 08:00-22:00 when the Airport Air traffic control is open. Likewise deployment of the drone will not be made if there is a conflict in the airspace with manned aircrafts. Rainy weather or winds exceeding 8 m/s prohibits flights as well.

Feasibility is evaluated and measured from the following aspects:

1. Operational factors Weather: a) rain, b) wind c) other. Conflict in airspace: a) manned aircraft b) unmanned aircraft. Obstacles prohibiting flight or delivery: a) constructed b) natural Time from dispatch to to take- off (min:sec). Time from dispatch to arrival (min:sec). Proportions are measured out of cases with a) Take-off b) no take-off c) aborted missions (%)
2. Human resources Adherence to protocol by: a) Dispatcher b) Drone pilot c) Air traffic leader. Proportions are measured out of cases with neglected protocol prohibiting mission completion, a) no alerts b) no take off c) aborted missions (%)
3. Technological functionality Drone, winch, Network, AED, Hangar, navigational software, global positioning system precision, Dispatch centre system (CoordCOM -Dispatch centre automated alert).

Proportions are measured out of cases where technological functionality prohibited mission completion a) no take-off b) aborted missions. (%)

Adverse advents (AE) and serious adverse events (SAE) in relation to AED-drone mission /use will be logged continuously. An adverse event may be caused by drone crash or risc of injury or death due to conflict in airspace or technological impairment.

An AE is considered serious if it:

* Results in death
* Is immediately life-threatening
* Requires hospitalisation or prolongation of existing hospitalization
* Results in persistent or significant disability or incapacity

Events that are related to the patient in cardiac arrest and would be expected in patients undergoing attempted resuscitation should NOT be reported. These include:

* Death
* Hospitalisation
* Persistent or significant disability or incapacity
* Organ failure

All events categorised as serious must be reported to the study administration within 24 hours of becoming aware of the event.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Out-Of-Hospital Cardiac Arrest

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Totally n=3 AED-drones are deployed as a complement to standard care (EMS) in all cases of suspected OHCA occurring within service areas
Primary Study Purpose

OTHER

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Delivery of automated external defibrillators using drones

Three drone systems are setup to be deployed in suspected OHCA cases as a complement to EMS. This is a single-arm intervention evaluating feasibility in:

* Operational feasibility (Legislation, Weather conditions, conflict in airspace)
* Participant feasibility (Failure to respond; Dispatcher, Drone-pilot, Air traffic controller)
* Technological feasibility (Drone technology, software, winch-system , 4G network, radio communication

Group Type EXPERIMENTAL

Automated flying Drone carrying an Automated external defibrillator (AED)

Intervention Type DEVICE

Totally n=3 drones are equipped with automated external defibrillators (AEDs). These drones are deployed by the dispatch centre to cases of suspected out-of-hospital cardiac (OHCA) as a complement to standard care (ambulance/EMS) over 4 months during daytime Monday to Sunday 08:00-22:00. The bystander onsite receives instructions from the dispatcher to retrieve the AED outside the house when it has been delivered by the drone. The bystander attaches the AED to the patients chest to facilitate early defibrillation.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Automated flying Drone carrying an Automated external defibrillator (AED)

Totally n=3 drones are equipped with automated external defibrillators (AEDs). These drones are deployed by the dispatch centre to cases of suspected out-of-hospital cardiac (OHCA) as a complement to standard care (ambulance/EMS) over 4 months during daytime Monday to Sunday 08:00-22:00. The bystander onsite receives instructions from the dispatcher to retrieve the AED outside the house when it has been delivered by the drone. The bystander attaches the AED to the patients chest to facilitate early defibrillation.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* All suspected OHCA
* Within n=3 service areas
* Hours of operation: 08:00-22:00

Exclusion Criteria

* Children \<8 years
* Trauma
* EMS-witnessed cases
Minimum Eligible Age

8 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

SOS Alarm Sverige AB

UNKNOWN

Sponsor Role collaborator

Everdrone AB

UNKNOWN

Sponsor Role collaborator

Karolinska Institutet

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Andreas Claesson

Associate professor

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Andreas Claesson, PhD

Role: PRINCIPAL_INVESTIGATOR

Centre for resuscitation science, Karolinska Institutet

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Göteborg AED-drone service areas

Gothenburg, , Sweden

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Sweden

References

Explore related publications, articles, or registry entries linked to this study.

Schierbeck S, Hollenberg J, Nord A, Svensson L, Nordberg P, Ringh M, Forsberg S, Lundgren P, Axelsson C, Claesson A. Automated external defibrillators delivered by drones to patients with suspected out-of-hospital cardiac arrest. Eur Heart J. 2022 Apr 14;43(15):1478-1487. doi: 10.1093/eurheartj/ehab498.

Reference Type DERIVED
PMID: 34438449 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

AC1

Identifier Type: -

Identifier Source: org_study_id

More Related Trials