International Study to Evaluate Outcomes and Safety of Patients Undergoing ERCP Using a Single-use Cholangioscope and Single-use Duodenoscope

NCT ID: NCT04712253

Last Updated: 2022-09-21

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Total Enrollment

50 participants

Study Classification

OBSERVATIONAL

Study Start Date

2021-01-27

Study Completion Date

2021-07-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Since its introduction more than 40 years ago, endoscopic retrograde cholangiopancreatography (ERCP) has fundamentally changed the treatment of biliopancreatic diseases. Since late 1970s there have been sporadic reports of nosocomial infections linked to endoscopic procedures, the majority caused by inadequate reprocessing of endoscopes. Infections due to multidrug-resistant organisms (MDROs) however have increasingly become a concern in health care, including in gastrointestinal (GI) endoscopy. Since 2010, reports of individual cases and serial outbreaks of MDRO infections associated with ERCP have been published worldwide. This is because, unlike a gastroscope or colonoscope, the duodenoscope is a complex instrument with unique mechanical features incorporated at the distal tip. This includes a recessed space containing an elevator, a wire cable that moves the elevator, working channel, and most recently, a seal that prevents contamination of the elevator wire channel. This complex design creates hard-to-reach areas that make optimal mechanical cleaning and disinfection difficult. With the aim of overcoming these issues, a single-use duodenoscope (EXALT Model D, Boston Scientific Corporation, Marlborough, Massachusetts, USA) has been developed in the United States of America (USA) and approved by the United States Food and Drug Administration (FDA) for clinical use in December 2019. Different studies evaluating this new device, including randomized clinical trials (RCTs), have already been published, which have confirmed that single-use duodenoscopes represent an alternative to reusable duodenoscopes for performing low-complexity ERCP procedures in experienced hands.

Digital Single Operator Cholangioscopy (D-SOC) using the single use Spyglass DS II (Boston Scientific Corporation, Marlborough, Massachusetts, USA) is a diagnostic and therapeutic modality which allows for direct endoscopic visualization of the biliopancreatic ductal system.

The principal diagnostic indication of D-SOC are bile duct or pancreatic strictures and unclear filling defects, adding direct endoscopic appearance data to biopsy sampling or brush cytology in order to improve the diagnostic yield.

The major therapeutic indication for D-SOC is lithotripsy for difficult biliary and pancreatic stones.

However, cholangioscopy increased the risk of post ERCP cholangitis. Bacteremia was suggested to be specifically related to cholangioscopy in 13.9% of 72 patients, based on serial blood samplings, and to be associated with biopsy sampling and strictures.

For this reason, the recent European Society of Gastrointestinal Endoscopy (ESGE) guideline suggests that patients should be considered to be at high risk for post-ERCP cholangitis when cholangioscopy is performed.

Presently, there are very few clinical reports about technical and clinical outcome of ERCPs performed with single use duodenoscope and there is complete lack of data about efficacy, safety and adverse events of the combination of the new single-use duodenoscope and the Spyglass DS II.

The aim of this multicentric retrospective study was to evaluate the technical success, clinical outcome and rate of adverse events of this procedure.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Biliary Condition

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

COHORT

Study Time Perspective

RETROSPECTIVE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

\- patients that required an ERCP with cholangioscopy performed with the single-use EXALT duodenoscope in combination with the Spyglass DS II

Exclusion Criteria

* Age \< 18
* Lack of follow-up data (30 days at least)
* Less than 3 cases performed during the study period
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Istituto Clinico Humanitas

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Endoscopy Unit, Humanitas Research Hospital

Rozzano, Milano, Italy

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Italy

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

101

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

SpyGlass AMEA Registry
NCT02281019 COMPLETED