Evaluation of the Sevoflurane Consumption During General Anesthesia When Using the MemsorbTM Membrane
NCT ID: NCT04539405
Last Updated: 2023-01-23
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
50 participants
OBSERVATIONAL
2021-05-04
2022-02-18
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
The Influence of Two Different CO2 Absorbers on Sevoflurane Consumption During Anaesthesia
NCT04271462
Efficacy of Remifentanil Compared to Lidocaine on the Incidence of Coughing During Emergence of Anesthesia
NCT01026129
Efficacy of Two Bolus Doses of Remifentanil on the Incidence of Coughing During Emergence of Anesthesia
NCT01489072
Efficacy of Alkalinized Lidocaine Compared to Remifentanil on the Incidence of Coughing During Emergence of Anesthesia
NCT01451840
A New and Innovative Method for CO2 Removal in Anesthetic Circuits: Replacing Chemical Granulate
NCT03014336
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Other parameters must be included in the analysis: fresh gas flow (FGF), carrier gas (air, O2, N2O) and potency of the anesthetic gas. Unfortunately, the majority of trials did not fully consider the FGF reduction and the fact that desflurane can be administered with new closed or very low-flow anesthesia circuits as opposed as the recommended 2L.min-1 that must be used for sevoflurane according to its monography when classical chemical absorbents are used by the anesthesia team. Most of the calculations were made on a purely theoretical approach that could be different from actual measurements based on a strictly monitored anesthesia practice.
For sevoflurane, the standard FGF must be set at 2L.min-1 as there is still controversy concerning impact on renal function at lower flows if classical CO2 absorbents are used. It is still not recommended to administer sevoflurane during anesthesia with a FGF lower than 2L.min-1 in Canada when classical chemical absorbents are used according to Baxter monography when classical absorbents are used on the anesthesia circuit (http://www.baxter.ca/fr\_CA/assets/downloads/monographs/Sevoflurane\_FR.pdf). When continuous and accurate gas monitoring and analysis is used as recommended nowadays by all GCP guidelines (see Canadian guidelines for anesthesia practice), the use of closed or semi-closed-circuit anesthesia with very low FGF might allow for a reduction of more than 80% of the anesthetic gas administration and its consequent pollution.
Moreover, there are few clinical trials looking at the sparing effect on the consumption of anesthetic gases when the depth of anesthesia is properly monitored, with the bispectral index for instance. Indeed, and because the lack of appropriate and precise technology at the time of completion of these trials, most of the studies used only end-tidal concentration in % of the anesthetic gases to argue that they had decreased the consumption of gas during surgery. This remains a very indirect assessing method based on extrapolations as opposed to direct measurements. Studying the effect of the combination of BIS/NOL indices (depth of hypnosis / depth of analgesia) monitoring and the use of our Drager ventilators with low-FGF on precise consumption in mL of each gas in a clinical environment allows to get high quality data never reported in the past. The fact this study also uses the NOL index to ensure that level of analgesia is controlled and equivalent in all groups will also reinforce the idea that what this study measures in terms of anesthetic gas consumption is based on the real need for hypnosis for each participant, and not an overconsumption of gas because of poor control of nociception and analgesia.
Recently a new device was developed to extract CO2 from the ventilation-anesthesia circuit: the new membrane technology-based product (Memsorb™, DMF Medical Inc., Halifax, NS, Canada). All details on the technology of this new membrane are given in the Appendix 1 attached to this proposal (see at the bottom of the present text).
For the last 5 years, clinical trials have been conducted in humans on the use of this new membrane technology-based product (Memsorb™, DMF Medical Inc., Halifax, NS, Canada) and compared this membrane to the classical Drägersorb 800+ CO2 absorbent (Dräger, Lübeck, Germany). After REB committee approval and investigational testing authorization (ITA) by Health Canada, Dr O. Hung (from Halifax, Canada) reported out of 200 patients (100 with MemsorbTM, 100 with DraegersorbTM; ClinicalTrials.gov Identifier: NCT03014336) comparable data regarding the end-tidal CO2 with a median of 5.1% for memsorb™ and 5.0% for control (DraegersorbTM), stable over 2h of anesthesia. Vapor consumption data did not differ significantly between the 2 groups. Anesthesiologist used fresh gas flows at their discretion (from 0.3L.min-1 to 2.7L.min-1). As a conclusion to their study, Memsorb™ was shown to remove CO2 out of an anesthesia circuit as safely and as efficiently than the classical CO2 absorbent (Draegersorb) BUT without the known limitations of chemical absorbents at very low gas flow (0.3L.min-1).
The study here aims at determining whether replacing the classical chemical absorber Dräegersorb 800+ on Dräeger Perseus A500 machines (Dräeger, Lübeck, Germany) by the new membrane technology-based product (Memsorb™, DMF Medical Inc., Halifax, NS, Canada) with the help of high-quality monitoring (BIS and NOL) and high-end ventilators (Dräeger Perseus A500 machines; Dräeger, Lübeck, Germany) that allow minimal fresh gas flow, will significantly decrease the use of sevoflurane and its related atmospheric pollution.
Indeed, MemsorbTM membrane allows to safely reduce the gas flow of the Dräger A500 ventilator as low as 0.2L.min-1 for the administration of sevoflurane (as there is no chemical reaction between the memsorb membrane and the sevoflurane, see ref 16) into the breathing circuit whereas the classical DräegersorbTM has to use a minimal gas flow of 2L.min-1 as recommended by the above cited monography (as below 2L.min-1, the Draegersorb might interact with sevoflurane and produce toxic compounds).
The impact of the present study will be that it will demonstrate sevoflurane administration at 0.2L.min-1 when using the MemsorbTM membrane (Memsorb™, DMF Medical Inc., Halifax, NS, Canada) reduces anesthesia related pollution to its minimum compared to the mandatory FGF at 2L.min-1 that MUST be used with the classical Draegersorb CO2 absorbent. As a consequence of this study, it is expected that anesthesiologists will drastically change towards the use of MemsorbTM in their clinical practice to significantly lessen the major impact they have on the environment.
The primary endpoint of this study is to show a significant decrease of at least 25% of the sevoflurane consumption when using MemsorbTM versus DrägersorbTM. This will be expressed in mL.kg-1.h-1 of surgery and the primary objective will focus on H1 of surgery, H1 starting at the time of incision (T0).
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
CASE_CONTROL
PROSPECTIVE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Memsorb
M for memsorbTM group with the minimal gas flow possible (sevoflurane administration at 0.2L.min-1) with the ventilator Draeger A-500 Perseus,
To evaluate sevoflurane consumption when using Memsorb
Sevoflurane administration at 0.2L.min-1 (minimal gas flow)
Dräegersorb
D for DraegersorbTM group with gas flow at 2L.min-1 (classical sevoflurane administration) with the same ventilator Draeger A-500 Perseus.
To evaluate sevoflurane consumption when using classical Dräegersorb
Sevoflurane administration at 2L.min-1 (classical gas flow)
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
To evaluate sevoflurane consumption when using Memsorb
Sevoflurane administration at 0.2L.min-1 (minimal gas flow)
To evaluate sevoflurane consumption when using classical Dräegersorb
Sevoflurane administration at 2L.min-1 (classical gas flow)
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Laparoscopic general, gynecological or urologic surgery requiring general anesthesia without additional regional anesthesia technique,
* Fully consented,
* BMI \< 40,
* Age \> 18.
Exclusion Criteria
* History of unstable coronary artery disease,
* Serious cardiac arrhythmia (including atrial fibrillation),
* History of substance abuse in the last 2 months prior to surgery,
* Chronic use of psychotropic and/or opioid drugs (still existing within the last month prior to surgery,
* History of psychiatric diseases,
* History of refractory PONV in previous surgery,
* Allergy to any drug used in the study protocol,
* Non-scheduled surgery,
* Refusal of the patient for participation in the study.
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
DMF Medical Incorporated
INDUSTRY
Ciusss de L'Est de l'Île de Montréal
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Philippe Richebe
MD, PhD, Professor with Tenure, Director of Research, Department of Anesthesiology and Pain Medicine, University of Montreal (UDeM), Maisonneuve Rosemont Hospital, CEMTL
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Philippe PR Richebe, MD, PhD
Role: PRINCIPAL_INVESTIGATOR
CIUSSS Est de l'île de Montréal
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Hopital Maisonneuve Rosemont, CIUSSS de l'Est de l'Ile de Montréal
Montreal East, Quebec, Canada
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
2020-2083
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.