Optimizing Volunteer Comfort for Transcranial Electrical Stimulation (TES): An Assessment

NCT ID: NCT04474015

Last Updated: 2025-03-28

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

ENROLLING_BY_INVITATION

Clinical Phase

NA

Total Enrollment

75 participants

Study Classification

INTERVENTIONAL

Study Start Date

2014-05-24

Study Completion Date

2029-02-12

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Transcranial electrical stimulation (TES) utilizing weak electrical fields (\<5 milliamps of current - as proposed in the present pilot study) is an extremely safe therapeutic technique in use for over 40 years. During that time, TES has never been associated with a serious adverse event in a research setting nor a serious reported adverse event in a clinical setting. The main side effect associated with TES is irritation of the skin beneath the electrodes (as is commonly found from similar preparations used for polysomnography). The purpose of this pilot study is to identify the type of electrode preparation that maximizes subject comfort during transdermal/transcranial electrical stimulation (TES) using the NeuroConn DC Plus Stimulator.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

In this study, volunteers will be divided into groups based on the nature of the stimulation waveform utilized (DC 0.75 Hz, modified AC 0.75 Hz, AC sinusoidal 3.0 Hz or pulsed stimulation of up to 500 ms duration). These waveforms were chosen based on the physiology of slow-wave sleep (SWS). Ultimately, the goal is to use TES during sleep to enhance the slow-wave activity (SWA) of sleep. Slow-wave sleep is characterized by two main frequency bands with differing underlying physiologies: (1) slow oscillation activity with a peak of 0.75 Hz, and (2) delta activity with a peak of approximately 3.0 Hz. Therefore, in future studies, the plan is to stimulate at one or both of these frequencies. The endogenous slow activity of the brain consists of electrical fields of "alternating current" with periods of relative cellular depolarization and periods of relative cellular hyperpolarization. The goal is to enhance this endogenous behavior with transcranial electrical stimulation at the two major slow- wave frequencies (0.75 Hz, 3.0 Hz), or using a pulsed stimulation paradigm to induce slow wave activity.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Performance Enhancing Product Use Sleep

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NON_RANDOMIZED

Intervention Model

SEQUENTIAL

Groups A, B and C are run sequentially.
Primary Study Purpose

BASIC_SCIENCE

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Part A, Group 3

Forearm stimulation during wake (study PART A) - electrode placement = volar surface of forearm, 2 electrodes (cathode and anode): Group 3 will receive forearm stimulation at 3.0 Hz with an alternating current (AC) sinusoidal waveform while awake.

Group Type ACTIVE_COMPARATOR

transcranial electric stimulation

Intervention Type DEVICE

NeuroConn® DC Plus stimulator: the NeuroConn® stimulator can be programmed with specific frequencies of stimulation ranging from 0.5 to 500 Hz. This device is therefore appropriate for the present study to stimulate only at 0.75 or 3.0 Hz. Also, the NeuroConn only allows low current intensities to be chosen. The maximum current intensity that can be delivered with this stimulator is 5 milliamps.

Part B, Group 4

Scalp stimulation during sleep (study PART B) - bilateral electrode pairs placed on the upper forehead near the midline (F3 and F4) and adjacent to the ear in the mastoid region (M1 and M2). roup 4 will receive scalp stimulation at 0.75 Hz with an oscillating direct current (DC) waveform during sleep.

Group Type ACTIVE_COMPARATOR

transcranial electric stimulation

Intervention Type DEVICE

NeuroConn® DC Plus stimulator: the NeuroConn® stimulator can be programmed with specific frequencies of stimulation ranging from 0.5 to 500 Hz. This device is therefore appropriate for the present study to stimulate only at 0.75 or 3.0 Hz. Also, the NeuroConn only allows low current intensities to be chosen. The maximum current intensity that can be delivered with this stimulator is 5 milliamps.

Part B, Group 5

Scalp stimulation during sleep (study PART B) - bilateral electrode pairs placed on the upper forehead near the midline (F3 and F4) and adjacent to the ear in the mastoid region (M1 and M2). Group 5 will receive scalp stimulation at 0.75 Hz with a modified alternating current (AC) waveform during sleep.

Group Type ACTIVE_COMPARATOR

transcranial electric stimulation

Intervention Type DEVICE

NeuroConn® DC Plus stimulator: the NeuroConn® stimulator can be programmed with specific frequencies of stimulation ranging from 0.5 to 500 Hz. This device is therefore appropriate for the present study to stimulate only at 0.75 or 3.0 Hz. Also, the NeuroConn only allows low current intensities to be chosen. The maximum current intensity that can be delivered with this stimulator is 5 milliamps.

Part B, Group 6

Scalp stimulation during sleep (study PART B) - bilateral electrode pairs placed on the upper forehead near the midline (F3 and F4) and adjacent to the ear in the mastoid region (M1 and M2). Group 6 will receive scalp stimulation at 3.0 Hz with an alternating current (AC) sinusoidal waveform during sleep.

Group Type ACTIVE_COMPARATOR

transcranial electric stimulation

Intervention Type DEVICE

NeuroConn® DC Plus stimulator: the NeuroConn® stimulator can be programmed with specific frequencies of stimulation ranging from 0.5 to 500 Hz. This device is therefore appropriate for the present study to stimulate only at 0.75 or 3.0 Hz. Also, the NeuroConn only allows low current intensities to be chosen. The maximum current intensity that can be delivered with this stimulator is 5 milliamps.

Part C, Group 7

Pulsed Stimulation: Group 7 (Part C)will receive a series of brief stimulations of up to 500 millisecond duration and of up to 5 milliamperes of current, using either metal electrodes or sponge electrodes as stimulating electrodes.

Group Type ACTIVE_COMPARATOR

transcranial electric stimulation

Intervention Type DEVICE

NeuroConn® DC Plus stimulator: the NeuroConn® stimulator can be programmed with specific frequencies of stimulation ranging from 0.5 to 500 Hz. This device is therefore appropriate for the present study to stimulate only at 0.75 or 3.0 Hz. Also, the NeuroConn only allows low current intensities to be chosen. The maximum current intensity that can be delivered with this stimulator is 5 milliamps.

Part A, Group 1

Forearm stimulation during wake (study PART A) - electrode placement = volar surface of forearm, 2 electrodes (cathode and anode): Group 1 will receive forearm stimulation at 0.75 Hz with an oscillating direct current (DC) waveform while awake.

Group Type ACTIVE_COMPARATOR

transcranial electric stimulation

Intervention Type DEVICE

NeuroConn® DC Plus stimulator: the NeuroConn® stimulator can be programmed with specific frequencies of stimulation ranging from 0.5 to 500 Hz. This device is therefore appropriate for the present study to stimulate only at 0.75 or 3.0 Hz. Also, the NeuroConn only allows low current intensities to be chosen. The maximum current intensity that can be delivered with this stimulator is 5 milliamps.

Part A, Group 2

Forearm stimulation during wake (study PART A) - electrode placement = volar surface of forearm, 2 electrodes (cathode and anode): Group 2 will receive forearm stimulation at 0.75 Hz with a modified alternating current (AC) waveform while awake.

Group Type ACTIVE_COMPARATOR

transcranial electric stimulation

Intervention Type DEVICE

NeuroConn® DC Plus stimulator: the NeuroConn® stimulator can be programmed with specific frequencies of stimulation ranging from 0.5 to 500 Hz. This device is therefore appropriate for the present study to stimulate only at 0.75 or 3.0 Hz. Also, the NeuroConn only allows low current intensities to be chosen. The maximum current intensity that can be delivered with this stimulator is 5 milliamps.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

transcranial electric stimulation

NeuroConn® DC Plus stimulator: the NeuroConn® stimulator can be programmed with specific frequencies of stimulation ranging from 0.5 to 500 Hz. This device is therefore appropriate for the present study to stimulate only at 0.75 or 3.0 Hz. Also, the NeuroConn only allows low current intensities to be chosen. The maximum current intensity that can be delivered with this stimulator is 5 milliamps.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Exclusion Criteria

* Self-reported habitual nightly sleep amounts outside the target range of 6-9 hours (i.e., less than 6 hours per night or more than 9 hours per night, on average):
* Nighttime lights-out times earlier than 2100 hours on average during weeknights (Sunday through Thursday) for the past month
* Morning wake-up times later than 0900 on average during weekdays (Monday through Friday) for the past month.
* History of cardiovascular disease (to include but not limited to arrhythmias, valvular heart disease, congestive heart failure, history of sudden cardiac death or myocardial infarction)
* Reported habitual napping (\> 3 times a week in conjunction with normal sleep habits)
* Resting blood pressure above 140/90
* Resting pulse \> 110
* Neurologic disorder (to include but not limited to epilepsy or another seizure disorder, amnesia for any reason, hydrocephalus, MS, narcolepsy or other sleep disorders)
* Kidney disease
* History of psychiatric disorder requiring hospitalization or psychiatric medication for any length of time
* Beck Depression Inventory score of 14 or above
* Underlying pulmonary disease requiring daily inhaler use
* Regular nicotine use (or addiction) (defined as more than 1 cigarette or equivalent per week) within the last 1 year
* Positive nicotine/cotinine screen as determined by NicCheck™ I test strips
* Heavy alcohol use to be determined by the PI or his/her representative (minimum limit to define heavy alcohol use is 14 drinks per week)
* Use of other illicit drugs (to include but not limited to benzodiazepines, amphetamines, cocaine, marijuana)
* Known liver disease or liver abnormalities as determined by a laboratory test
* Self-reported history of caffeine use in excess of 400 mg (approximately 8 caffeinated sodas or 3-4 cups of coffee) per day on average
* Pregnancy (females)
* Inability to read and sign consent
* Use of certain medications (including use of vitamins or supplements), to be determined on a case-by-case basis by the examining study licensed physician.
* BMI ≥ 30 (Obese Class I or greater)
* The PI also maintains the prerogative to disqualify a volunteer if it is deemed that the volunteer's participation would be unsafe for the volunteer or staff or would be disruptive to study conduct.
Minimum Eligible Age

18 Years

Maximum Eligible Age

39 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Walter Reed Army Institute of Research (WRAIR)

FED

Sponsor Role collaborator

U.S. Army Medical Research and Development Command

FED

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

WRAIR #1927

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Multiparameter Optimized tES for Memory in Aging
NCT06491264 NOT_YET_RECRUITING NA
Power Nap With TES-TI
NCT07090135 RECRUITING NA
At-Home tDCS as Maintenance Therapy
NCT07269964 RECRUITING NA