RFA Using Gradual RF Energy Delivery Mode With Octopus Electrodes
NCT ID: NCT04471272
Last Updated: 2021-03-17
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
NA
120 participants
INTERVENTIONAL
2020-01-06
2023-12-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Radiofrequency Ablation Using Combined RF Energy Delivery Mode and Octopus Electrodes for Hepatocellular Carcinoma
NCT06682377
Radiofrequency Ablation With Gradual Radiofrequency Energy Increment for Hepatocellular Carcinoma Treatment
NCT05397860
Radiofrequency Ablation Using Octopus Electrodes for Small Hepatocellular Carcinoma With No-touch Technique
NCT03375281
Radiofrequency Ablation Using Octopus Electrodes for Treatment of Focal Liver Malignancies
NCT02683538
RFA Using Combined Bipolar and Monopolar Energy Deliver With Twin Cooled-Wet Electrodes
NCT04331184
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The detailed plan of radio frequency ablation (RFA) will be implemented in accordance with the routine procedure of image evaluation prior to high frequency implementation. In other words, the location of the tumor on the Multiphasic CT or MRI and the RFA planning program at the 3D workstation (Philips, Intraportal) before RFA procedure, evaluate the tumor volume and the relationship with adjacent blood vessels, and insert the electrode for RFA After planning the number of ablation and the like, the location of the tumor in the ultrasound image was found in the pre-surgery image by fusion of the pre-surgery image and the ultrasound image using US-CT-MR fusion and contrast-enhanced ultrasonography, which are recently used. It will evaluate whether the tumors match, and also evaluate whether the distribution of the echo bubble and the tumor position coincide during the procedure in real time.
In addition, the degree of stiffness of the parenchyma will be measured by using an ultrasound elastic technique. At this time, the ultrasonic fusion device to be used will be one of Phillips, GE, or one of the navigation systems of Siemens, Canon, and Samsung, available here. The fused image guides the location of the electrodes to be installed in the tumor, the number of electrodes, and a safe access route. If the extent of the tumor is not clearly visible, or the image before the procedure is too old (\> 6 weeks), low kVp or DECT will be conducted to evaluate the tumor's extent more accurately.
2. RFA procedure As the equipment of RFA, the multi-VIVA generator and octopus electrode used herein will be used. In the method of treatment, three high-frequency electrode needles were placed on the tumor according to the clinical need under the guidance of fusion ultrasound, and then the electrodes were cooled with saline, and the two electrodes were simultaneously applied with high-frequency waves for approximately 6-30 minutes depending on the size of the tumor. The temperature is maintained at 90-100 degrees Celsius. At this time, the high-frequency energy is increased by 10W at 30W intervals at 60Watt for the first 3 minutes, and then gradually increased by 10W per minute after 100W.
The location of the tumor on the ultrasound image by fusion of the ultrasound image with the pre-procedure using the US-CT-MR fusion tool (Navigator- GE, PercuNav-Phillips, Canon, S-fusion: Samsung), which is frequently used in RFA procedures. It will evaluate whether the tumors found in the images before the procedure match, and also evaluate whether the distribution of the echo bubble and the tumor location coincide during the procedure in real time. At this time, the navigation systems used by Samsung, Phillips, GE, and Canon will be used as the ultrasonic fusion device to be used. In the Fusion US image, the Octopus electrode is safely placed in the tumor through the access path of the electrode already planned. Thereafter, while transmitting high-frequency energy, air bubbles are generated in the tumor on the ultrasound image, and an echogenic cloud is formed while the procedure is stopped when the echogenic cloud becomes larger than 5 mm than the tumor.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
* Control group: Over a period of two years from 2017 to 2018, the patients who performed RFA for HCC using octopus electrodes and the maximum high-frequency energy transfer mode technique were collected. After performing propensity score matching analysis using variables of liver function values, the same number of controls are selected and set.
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
RFA using gradual RF energy delivery mode
RFA therapy is performed on HCC less than 4 cm in size using an octopus electrode, a double-shift unipolar high-frequency transmission mode, and a gradual high-frequency energy loading mode.
RFA using gradual RF energy delivery mode with Octopus electrodes
RFA therapy is performed on HCC less than 4 cm in size using an octopus electrode, a double-shift unipolar high-frequency transmission mode, and a gradual high-frequency energy loading mode.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
RFA using gradual RF energy delivery mode with Octopus electrodes
RFA therapy is performed on HCC less than 4 cm in size using an octopus electrode, a double-shift unipolar high-frequency transmission mode, and a gradual high-frequency energy loading mode.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* 20 years old-85 years old
* Child-Pugh Class A
* among patients with chronic hepatitis or cirrhosis, MDCT or MRI hepatocellular carcinoma of less than 4 cm in size was suspected, and was referred to the radiology department considering clinical RFA therapy as a clinical judgment.
Exclusion Criteria
* if the tumor has a maximum size of more than 4 cm
* diffuse infiltrative HCC
* Child-Pugh class B or C
* If there is an invasion of liver vessels due to malignant HCC
* severe coagulopathy
* multiple distant metastasis
* situations where it is very unlikely to obtain appropriate data for research purposes
20 Years
85 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Seoul National University Hospital
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Jeong Min Lee
Professor
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Seoul National University Hospital
Seoul, , South Korea
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
H-1909-086-1064
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.