An Investigation of Functional Improvements in the RHEO KNEE Compared to Hydraulic Microprocessor Controlled Knees (MPKs)

NCT ID: NCT04023578

Last Updated: 2020-04-06

Study Results

Results available

Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.

View full results

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

15 participants

Study Classification

INTERVENTIONAL

Study Start Date

2015-06-30

Study Completion Date

2015-08-04

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The aim of this study was to evaluate the mobility, perceived safety and functioning of unilateral transfemoral (TF) amputees using the Rheo Knee XC compared to their existing prosthetic knee (RHEO KNEE II, III or Genium, X2 or X3) after 3 weeks of use.

The primary objective of the study was to determine/investigate whether unilateral (TF) amputees can apply and benefit from the stair ascent function of the Rheo Knee XC and compare the stair ascent function and automatic cycling detection of the Rheo Knee XC to hydraulic microprocessor controlled knees (MPK-HY).

The testing was conducted in a non-blinded, multicenter, prospective within subject comparison, with a subgroup analysis with Magneto-rheologic microprocessor controlled knees (MPK-MR) subgroup and MPK-HY subgroup comparing to the Rheo knee XC.

A convenience sample of 15 transfemoral amputee users was recruited at 4 study sites.

Inclusion criteria:

* Cognitive ability to understand all instructions and questionnaires in the study;
* Unilateral knee-disarticulated or transfemoral users fitted to Rheo Knee II,III or Genium
* Willing and able to participate in the study and follow the protocol
* Confident prosthetic users for more than 3 months
* Older than 18 years Exclusion Criteria
* Patients with the following characteristics are not eligible for study entry:
* 50Kg\> body weight \> 136Kg
* Users with cognitive impairment
* Users not understanding the function of the knee
* Users not able to charge the battery Testing was conducted between June and August 2015 in four US locations. Participants visited the study location twice, for approximately 3 hours per visit. First time for the baseline measure and initial fitting and secondly after 3 weeks of accommodation on the Rheo knee XC, performing the same measures as for the baseline. Measures included 6 minute walk test with Borg scale CR pre and post, L-test, stair assessment index, stair and bicycle evaluation and Prosthesis evaluation questionnaire mobility section (PEQ MS12/5)

For statistics repeated measures analysis of variance (ANOVA) comparing baseline to 3 week follow up were performed.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Recruiting and participants:

A convenience sample of 15 transfemoral amputee users was recruited at 4 study sites. Potential subjects were identified from the customer base of study sites, local investigators evaluated , based on previous experience of interaction with and servicing of patients, if a potential participant is cognitively capable. If a potential participant fitted the inclusion and exclusion criteria the local investigator (CPO-Certified prosthetist/orthotist) contacted them via telephone. During the telephone call the investigator verified if they were interested in participating in the study. If interest was expressed and eligibility criteria was met an appointment was made for enrollment in the study. Informed consent was obtained from all participants at the beginning of the first visit, prior to clinical testing and prosthetic fitting.

Setting:

Testing was conducted in four US locations with daily mean temperature during the testing period between 79.3 to 85.3 degrees Fahrenheit, Fort Worth (Baker orthotics \& prosthetics), Jackson (Methodist Rehabilitation Center), Roanoke (Virginia Prosthetics \& orthotics) and Orlando (Ossur facility, Florida gait lab) . Participants had to visit the study location twice, for approximately 3 hours per visit. First time for the baseline measure and initial fitting and secondly after 3 weeks of accommodation on the Rheo knee XC, performing the same measures as for the baseline. No standard exists for follow up time needed for amputees to adapt to a new prosthesis however, a follow up time of at least 3 weeks is widely used and considered sufficient for functional comparison.

All users used their existing sockets throughout the testing without modifications. One group consisted of 9 previous MPK-magnetorheologic (MPK-MR), Rheo knee II and III, users and the second group of 4 previous MPK-hydraulic knee (MPK-HY), Genium, users. By maintaining alignment and foot choice in the previous Rheo knee group confounding factors could be minimized. The previous MPK-HY was provided with an alignment offset adapter and a consistent foot choice, XC Vari-Flex, at initial fitting. The load line was controlled to be equal prior and post initial fitting. During the initial fitting the MPK-HY users which were new to the XC Vari-Flex had to undergo an evaluation for the foot stiffness as defined by the manufacturer (Ossur ehf). Foot configuration had to be rated acceptable or better with all users that were provided with a XC Vari-Flex.

13 users completed a 3 week evaluation in a multi-center trial with the RHEO KNEE XC at which point they performed Borg Scale CR 10 pre, 6MWT, Borg Scale CR 10 post, L-Test, stair and bicycle evaluation and prosthesis evaluation quesionnaire mobility section) PEQ MS 12/5) on functional ability and prosthesis satisfaction in this order.

The Borg Scale CR 10 is an accepted and reliable psychophysical score which has been used to report on the perceived level of exertion in lower limb amputees. The 6MWT has shown to be a reliable measure in amputees and differentiate among functional levels with a minimum detectable change for unilateral trans-tibial and transfemoral found at 45m. The L-Test is a valid indicator for functional mobility and showed high intraclass correlation, interrater reliability, and minimal bias upon retesting with a moderate correlation to self-reports like the PEQ MS 12/522 which itself is a reliable and valid measure for lower limb amputee assessing psychometric properties.

Ambulating stairs was evaluated as a timed parameter split up in ascending and descending. An observer score/SAI for the gait quality, and a user score/self-report with a 5 point scale (Please rate your ability when using the prosthesis: unable=0, highly difficult=1, moderate difficulty=2, little difficulty=3, no problems=4) similar to the PEQ MS 12/5 scores described by Franchignoni et. al.22 was used. The Rheo Knee XC stair mode can be entered by flexing the hip of the amputated side faster and to a higher degree than in typical walking. The Rheo knee XC will then maintain a flexed position to allow the user to position the foot onto the next stair case. The Genium requires the amputee to stop in front of the stairs and initiate a fast movement into hip-hyperextension to allow the knee to maintain a flexed position. For adapting these two different techniques each user was given 30min training time with instructions to get familiar with the stairs and the operation of the knee in specific location. Equal time was given after initial fitting which was important to the previous MPK-MR knee users who have not used the stair mode before. For the bicycle evaluation the same 5 point scale for the self-report assessment was applied to report on 2 questions: Rate your ability to ride the bicycle and rate your ability to stop the bike with the prosthetic side down.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Prosthesis User Amputation

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Rheo Knee XC

Amputee subjects currently using either magneto-rehologic or hydraulic MPKs are fitted with the Rheo Knee XC, a magneto-rheologic MPK.

Group Type EXPERIMENTAL

RHEO KNEE XC

Intervention Type DEVICE

Microprocessor controlled knee using Magneto-Rheologic techonology.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

RHEO KNEE XC

Microprocessor controlled knee using Magneto-Rheologic techonology.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Cognitive ability to understand all instructions and questionnaires in the study;
* Unilateral kneedisartic or transfemoral users fitted to Rheo Knee II,III Genium or X2 or X3
* Willing and able to participate in the study and follow the protocol
* Confident prosthetic users for more than 3 months
* Older than 18 years

Exclusion Criteria

* 50Kg\> body weight \> 136Kg
* Users with cognitive impairment
* Users not understanding the function of the knee
* Users not able to charge the battery
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Baker Orthotics & Prosthetics

INDUSTRY

Sponsor Role collaborator

Virginia Prosthetics & Orthotics

INDUSTRY

Sponsor Role collaborator

Methodist Rehabilitation Center

OTHER

Sponsor Role collaborator

Össur Iceland ehf

INDUSTRY

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Justin Pratt, M.Sc.

Role: PRINCIPAL_INVESTIGATOR

Ossur Iceland ehf

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Ossur Americas, Florida Gait lab

Orlando, Florida, United States

Site Status

Methodist Rehabilitation Center

Flowood, Mississippi, United States

Site Status

Baker Orthotics & Prosthetics

Fort Worth, Texas, United States

Site Status

Virginia Prosthetics & Orthotics

Roanoke, Virginia, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

References

Explore related publications, articles, or registry entries linked to this study.

Hafner BJ, Willingham LL, Buell NC, Allyn KJ, Smith DG. Evaluation of function, performance, and preference as transfemoral amputees transition from mechanical to microprocessor control of the prosthetic knee. Arch Phys Med Rehabil. 2007 Feb;88(2):207-17. doi: 10.1016/j.apmr.2006.10.030.

Reference Type BACKGROUND
PMID: 17270519 (View on PubMed)

Starholm IM, Gjovaag T, Mengshoel AM. Energy expenditure of transfemoral amputees walking on a horizontal and tilted treadmill simulating different outdoor walking conditions. Prosthet Orthot Int. 2010 Jun;34(2):184-94. doi: 10.3109/03093640903585016.

Reference Type BACKGROUND
PMID: 20141493 (View on PubMed)

Borg G. Psychophysical scaling with applications in physical work and the perception of exertion. Scand J Work Environ Health. 1990;16 Suppl 1:55-8. doi: 10.5271/sjweh.1815.

Reference Type BACKGROUND
PMID: 2345867 (View on PubMed)

Gailey RS, Roach KE, Applegate EB, Cho B, Cunniffe B, Licht S, Maguire M, Nash MS. The amputee mobility predictor: an instrument to assess determinants of the lower-limb amputee's ability to ambulate. Arch Phys Med Rehabil. 2002 May;83(5):613-27. doi: 10.1053/apmr.2002.32309.

Reference Type BACKGROUND
PMID: 11994800 (View on PubMed)

Deathe AB, Miller WC. The L test of functional mobility: measurement properties of a modified version of the timed "up & go" test designed for people with lower-limb amputations. Phys Ther. 2005 Jul;85(7):626-35.

Reference Type BACKGROUND
PMID: 15982169 (View on PubMed)

Franchignoni F, Monticone M, Giordano A, Rocca B. Rasch validation of the Prosthetic Mobility Questionnaire: A new outcome measure for assessing mobility in people with lower limb amputation. J Rehabil Med. 2015 May;47(5):460-5. doi: 10.2340/16501977-1954.

Reference Type BACKGROUND
PMID: 25783231 (View on PubMed)

Resnik L, Borgia M. Reliability of outcome measures for people with lower-limb amputations: distinguishing true change from statistical error. Phys Ther. 2011 Apr;91(4):555-65. doi: 10.2522/ptj.20100287. Epub 2011 Feb 10.

Reference Type BACKGROUND
PMID: 21310896 (View on PubMed)

Franchignoni F, Giordano A, Ferriero G, Orlandini D, Amoresano A, Perucca L. Measuring mobility in people with lower limb amputation: Rasch analysis of the mobility section of the prosthesis evaluation questionnaire. J Rehabil Med. 2007 Mar;39(2):138-44. doi: 10.2340/16501977-0033.

Reference Type BACKGROUND
PMID: 17351696 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

CIP-P197

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Personalizing MPK Prescription
NCT06399471 COMPLETED NA
Active Knee Prosthesis Study
NCT06700668 ACTIVE_NOT_RECRUITING NA
Anatomic Congruent Prosthetic Knee Design
NCT03633201 ACTIVE_NOT_RECRUITING NA
A Powered Exoskeleton for Veterans With Knee OA
NCT04653896 ACTIVE_NOT_RECRUITING NA