Liver Biopsy Using a 19 Gauge Fine Needle Biopsy Needle
NCT ID: NCT03910790
Last Updated: 2020-07-16
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
WITHDRAWN
NA
INTERVENTIONAL
2019-03-20
2019-11-22
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Endoscopic Ultrasound Guided Liver Biopsy
NCT03307811
19Gauge Fine Needle Biopsy (FNB) Versus 22Gauge FNB for Endoscopic Ultrasound Guided Liver Biopsy (EUS-LB)
NCT04806607
19 Versus 22-Gauge Needle for EUS-LB
NCT02967991
Endoscopic Ultrasound vs Percutaneous Route for Liver Biopsy
NCT04003766
Efficacy of Endoscopic Ultrasound Guided Liver Biopsy Using Dynamic Wet Technique
NCT06833619
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Endoscopic ultrasound guided liver biopsy (EUS-LB) is proposed as a newer method that may offer several potential advantages over existing techniques for attaining liver tissue 3-8. It can be performed in an outpatient setting and offers the comfort of sedation and analgesia. EUS-LB is a technically reproducible approach regardless of body habitus, because the needle only requires traversing the gastric or duodenal wall to reach hepatic parenchyma. It also offers the benefit of a comprehensive evaluation of the GI tract, including screening or surveying for esophageal varices. EUS provides high resolution images of left lobe of the liver and a good portion of the right lobe of the liver. This coupled with Doppler capability the biopsy needle can be safely directed into the liver for sampling under real time image guidance. Intervening structures such as pleura, bowel loops and gallbladder can be easily seen by EUS and thus avoided that further decreases the risk of adverse events. It has been recognized that sampling error can lead to diagnostic inaccuracy of a biopsy from a single site 9. As compared to USG or CT scan the EUS allows easy and safe biopsy of both left and right lobes of the liver during same setting, potentially addressing concerns about sampling error.
The cost of the endoscopic procedure is the main expense of EUS-LB. Thus, this approach is best used for patients requiring EUS for evaluation of elevated liver tests. If no obstructive lesion is identified by EUS that will require ERCP then it would cost-effective to perform EUS LB during the same setting without much additional time and risks. This approach can spare the patient the additional discomfort and expense of a second dedicated LB procedure by any of the other available techniques (percutaneous, transjugular etc.). In such setting the equipment costs for the EUS-LB will mainly include only the Fine Needle Biopsy (FNB) needle, which is similar in expense to the cost of needles for the transjugular or percutaneous approach.
The traditionally used transcutaneous LB needle is 16 gauge (G) while largest EUS biopsy needle is 19 gauge. The smaller size of the needle is expected to decrease the complications rate (mainly pain and bleeding) even further. Many studies using a 19 gauge Tru-cut biopsy or Fine Needle Aspiration (FNA) needle to acquire liver tissue have obtained specimens adequate for histologic diagnosis 3-7 but there has been a wide range of specimen adequacy (19-100%). Overall, there is limited data comparing the diagnostic yield of different FNA and FNB needles.
In a recently reported systematic review and meta-analysis 10, the insufficient specimen rate with 19 gauge FNA needle was 4% compared with 20% with 19 gauge core needles, with a p value of 0.03. FNA needle demonstrated a non-significant trend toward better diagnostic results (95.8% vs 92.7%, p=0.59) and a non-significant trend toward lower rates of adverse-events (0.9% vs 2.7%, p=0.28) when compared with the core biopsy needles. The 19-gauge FNA needle used was EchoTip (Wilson Cook Medical) in one study 6 and Expect (Boston Scientific) in rest two studies 8,11. The various types of core needles used were Quick-Core 12, Pro-Core 12, SharkCore 13,14, and the Acquire needle 15.
The 19 gauge FNA needle was used in 22 patients and yielded adequate tissue for histological analysis in 20 (91 %) of them 6. In the largest multi-center EUS-LB study of 110 patients 8 where a 19 gauge FNA needle was used for liver biopsy, bilobular liver biopsy was obtained in 68 patients (62%). Even though 108 (98 %) of 110 patients yielded specimens sufficient for definitive pathological diagnosis, there were five patients where the tissue yield was less than 6 complete portal triads (CPTs) with aggregate length less than 15 mm; the value used as a reference standard in recent studies 4-6. The rate of complications was very low (1/110) 0.9% in this study.
Two ex-vivo studies demonstrated the significantly superior histologic yield, with a greater number of CPT, obtained using the novel 19 gauge SharkCore FNB 16 and 22 gauge SharkCore FNB needles 16,17, compared with 18 gauge percutaneous needles and existing 19 gauge FNA and other core needles.
The study team prospectively aimed at evaluating the diagnostic adequacy and safety of EUS-LB using a 22 gauge FNB needle while using proper technique of tissue expression from the needle to prevent fragmentation of the specimen. Forty patients underwent EUS-LB. Adequate core tissue for histopathological evaluation was obtained in all 40 patients (100%) without the use of suction. The overall tissue yield per pass was a median core length (longest fragment per pass) of 5 mm (range 2mm-33mm) and median CPT of 17 (range 8-65). The most common minor complication was mild abdominal pain in 3 patients (17.6 %) at 24 hours. There were no major complications, and no immediate or delayed bleeding (presented at DDW 2018).
In this study the study team will use a 19 gauge FNB needle, using same technique as with 22 gauge needle, to obtain liver histological specimen in regards to core length and the number of CPT.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
DIAGNOSTIC
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
19 Gauge needle liver biopsy
Obtaining liver tissue with a 19 gauge core needle
19 gauge needle liver biopsy
Obtaining liver tissue with a 19 gauge core needle and whether a good core biopsy can be obtained without the use of suction and secondly to determine the diagnostic yield and safety of 19 gauge core needle for liver biopsy.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
19 gauge needle liver biopsy
Obtaining liver tissue with a 19 gauge core needle and whether a good core biopsy can be obtained without the use of suction and secondly to determine the diagnostic yield and safety of 19 gauge core needle for liver biopsy.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. Age ≥ 19 years
3. Willing to provide informed consent verbal or written.
Exclusion Criteria
2. Unable to safely undergo EUS for any reason
3. Coagulopathy (INR \>1.6, Thrombocytopenia with platelet count \<50,000/ml) for subjects on anti-coagulation therapy.
4. Unwilling or cognitively unable to provide informed consent verbal or written.
5. Pregnancy (confirmed with Standard of Care urine pregnancy test for all women with child-bearing potential only)
19 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
AdventHealth
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Muhammad Hasan, MD
Role: PRINCIPAL_INVESTIGATOR
Florida Hospital (AdventHealth Orlando)
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Center for Interventional Endoscopy - Florida Hospital
Orlando, Florida, United States
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Rockey DC, Caldwell SH, Goodman ZD, Nelson RC, Smith AD; American Association for the Study of Liver Diseases. Liver biopsy. Hepatology. 2009 Mar;49(3):1017-44. doi: 10.1002/hep.22742. No abstract available.
Kalambokis G, Manousou P, Vibhakorn S, Marelli L, Cholongitas E, Senzolo M, Patch D, Burroughs AK. Transjugular liver biopsy--indications, adequacy, quality of specimens, and complications--a systematic review. J Hepatol. 2007 Aug;47(2):284-94. doi: 10.1016/j.jhep.2007.05.001. Epub 2007 May 24.
Mathew A. EUS-guided routine liver biopsy in selected patients. Am J Gastroenterol. 2007 Oct;102(10):2354-5. doi: 10.1111/j.1572-0241.2007.01353_7.x. No abstract available.
Gleeson FC, Clayton AC, Zhang L, Clain JE, Gores GJ, Rajan E, Smyrk TC, Topazian MD, Wang KK, Wiersema MJ, Levy MJ. Adequacy of endoscopic ultrasound core needle biopsy specimen of nonmalignant hepatic parenchymal disease. Clin Gastroenterol Hepatol. 2008 Dec;6(12):1437-40. doi: 10.1016/j.cgh.2008.07.015. Epub 2008 Jul 26.
Dewitt J, McGreevy K, Cummings O, Sherman S, Leblanc JK, McHenry L, Al-Haddad M, Chalasani N. Initial experience with EUS-guided Tru-cut biopsy of benign liver disease. Gastrointest Endosc. 2009 Mar;69(3 Pt 1):535-42. doi: 10.1016/j.gie.2008.09.056.
Stavropoulos SN, Im GY, Jlayer Z, Harris MD, Pitea TC, Turi GK, Malet PF, Friedel DM, Grendell JH. High yield of same-session EUS-guided liver biopsy by 19-gauge FNA needle in patients undergoing EUS to exclude biliary obstruction. Gastrointest Endosc. 2012 Feb;75(2):310-8. doi: 10.1016/j.gie.2011.09.043.
Nakai Y, Samarasena JB, Iwashita T, Park DH, Lee JG, Hu KQ, Chang KJ. Autoimmune hepatitis diagnosed by endoscopic ultrasound-guided liver biopsy using a new 19-gauge histology needle. Endoscopy. 2012;44 Suppl 2 UCTN:E67-8. doi: 10.1055/s-0031-1291567. Epub 2012 Mar 6. No abstract available.
Diehl DL, Johal AS, Khara HS, Stavropoulos SN, Al-Haddad M, Ramesh J, Varadarajulu S, Aslanian H, Gordon SR, Shieh FK, Pineda-Bonilla JJ, Dunkelberger T, Gondim DD, Chen EZ. Endoscopic ultrasound-guided liver biopsy: a multicenter experience. Endosc Int Open. 2015 Jun;3(3):E210-5. doi: 10.1055/s-0034-1391412. Epub 2015 Feb 27.
Maharaj B, Maharaj RJ, Leary WP, Cooppan RM, Naran AD, Pirie D, Pudifin DJ. Sampling variability and its influence on the diagnostic yield of percutaneous needle biopsy of the liver. Lancet. 1986 Mar 8;1(8480):523-5. doi: 10.1016/s0140-6736(86)90883-4.
Mohan BP, Shakhatreh M, Garg R, Ponnada S, Adler DG. Efficacy and safety of EUS-guided liver biopsy: a systematic review and meta-analysis. Gastrointest Endosc. 2019 Feb;89(2):238-246.e3. doi: 10.1016/j.gie.2018.10.018. Epub 2018 Oct 31.
Gor N, Salem SB, Jakate S, Patel R, Shah N, Patil A. Histological adequacy of EUS-guided liver biopsy when using a 19-gauge non-Tru-Cut FNA needle. Gastrointest Endosc. 2014 Jan;79(1):170-2. doi: 10.1016/j.gie.2013.06.031. Epub 2013 Jul 31. No abstract available.
Sey MS, Al-Haddad M, Imperiale TF, McGreevy K, Lin J, DeWitt JM. EUS-guided liver biopsy for parenchymal disease: a comparison of diagnostic yield between two core biopsy needles. Gastrointest Endosc. 2016 Feb;83(2):347-52. doi: 10.1016/j.gie.2015.08.012. Epub 2015 Aug 13.
Nieto J, Khaleel H, Challita Y, Jimenez M, Baron TH, Walters L, Hathaway K, Patel K, Lankarani A, Herman M, Holloman D, Saab S. EUS-guided fine-needle core liver biopsy sampling using a novel 19-gauge needle with modified 1-pass, 1 actuation wet suction technique. Gastrointest Endosc. 2018 Feb;87(2):469-475. doi: 10.1016/j.gie.2017.05.013. Epub 2017 May 24.
Shah ND, Sasatomi E, Baron TH. Endoscopic Ultrasound-guided Parenchymal Liver Biopsy: Single Center Experience of a New Dedicated Core Needle. Clin Gastroenterol Hepatol. 2017 May;15(5):784-786. doi: 10.1016/j.cgh.2017.01.011. Epub 2017 Jan 23. No abstract available.
Lee WJ, Uradomo LT, Zhang Y, Twaddell W, Darwin P. Comparison of the Diagnostic Yield of EUS Needles for Liver Biopsy: Ex Vivo Study. Diagn Ther Endosc. 2017;2017:1497831. doi: 10.1155/2017/1497831. Epub 2017 Sep 13.
Schulman AR, Thompson CC, Odze R, Chan WW, Ryou M. Optimizing EUS-guided liver biopsy sampling: comprehensive assessment of needle types and tissue acquisition techniques. Gastrointest Endosc. 2017 Feb;85(2):419-426. doi: 10.1016/j.gie.2016.07.065. Epub 2016 Aug 13.
Rombaoa C CA. Mo1351 The safety and feasibileity of endoscopic ultrasound-guided parenchymal liver biopsy at a large community hospital. Gastrointestinal endoscopy; 87(6): AB458.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
1354057
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.