Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
40 participants
INTERVENTIONAL
2017-08-01
2018-10-01
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Liver Biopsy Using a 19 Gauge Fine Needle Biopsy Needle
NCT03910790
Endoscopic Ultrasound vs Percutaneous Route for Liver Biopsy
NCT04003766
19Gauge Fine Needle Biopsy (FNB) Versus 22Gauge FNB for Endoscopic Ultrasound Guided Liver Biopsy (EUS-LB)
NCT04806607
19 Versus 22-Gauge Needle for EUS-LB
NCT02967991
Wet Heparin for Obtaining Liver Tissue for EUS Guided Liver Biopsy
NCT03103997
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Endoscopic ultrasound guided liver biopsy (EUS-LB) is proposed as a newer method that may offer several potential advantages over existing techniques for attaining liver tissue. It can be performed in an outpatient setting and offers the comfort of sedation and analgesia. Endoscopic Ultrasound (EUS) provides high resolution images of left lobe of the liver and a good portion of the right lobe of the liver. This coupled with Doppler capability the biopsy needle can be safely directed into the liver for sampling under real time image guidance. Intervening structures such as pleura, bowel loops and gallbladder can be easily seen by EUS and thus avoided that further decreases the risk of adverse events. It has been recognized that sampling error can lead to diagnostic inaccuracy of a biopsy from a single site. As compared to USG or CT scan the EUS allows easy and safe biopsy of both left and right lobes of the liver during same setting, potentially addressing concerns about sampling error.
The cost of the endoscopic procedure is the main expense of EUS-LB. Thus this approach is best used for patients requiring EUS for evaluation of elevated liver tests. If no obstructive lesion is identified by EUS that will require endoscopic retrograde cholangiopancreatography (ERCP) then it would cost-effective to perform EUS-LB during the same setting without much additional time and risks. This approach can spare the patient the additional discomfort and expense of a second dedicated LB procedure by any of the other available techniques (percutaneous, transjugular etc.). In such setting the equipment costs for the EUS-LB will mainly include only the Fine Needle Biopsy (FNB) needle, which is similar in expense to the cost of needles for the transjugular or percutaneous approach.
The traditionally used transcutaneous LB needle is 16 gauge (G) while largest EUS biopsy needle is 19 G. The smaller size of the needle is expected to decrease the complications rate (mainly pain and bleeding) even further. Many studies using a 19 G Tru-cut biopsy or Fine Needle Aspiration (FNA) needle to acquire liver tissue have obtained specimens adequate for histologic diagnosis but there has been a wide range of specimen adequacy (19-100%). The 19 G Tru-cut biopsy needle has been associated with several technical difficulties that could reflect negatively on tissue adequacy.
While it is easy and straight forward to biopsy the left lobe of the liver with any EUS needle. The 19 G needle is a large bore needle for EUS use and it is sometimes difficult to attain an adequate position for biopsy specially in duodenum where scope is torqued and this is the only area of access to right lobe.
In this study the investigators will use a 22 G needle. Smaller caliber of the needle would not only make it technically easier to access right lobe of the liver through the duodenum, it is also expected to decrease the risks further due to smaller size. Also, the 22 G EUS-FNB needle has three cutting points at the cutting edge of the needle that provide stability at puncture while the high quality, fully formed heels are designed to maximize tissue capture and minimize fragmentation, that would result in attaining a good histological specimen, a main stay for liver biopsy.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
DIAGNOSTIC
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
22 gauge needle liver biopsy
EUS-LB will be performed using a 22 g FNB needle. Specimens obtained from each pass will be placed in a separate biopsy jar. If the third pass does not result in sufficient diagnostic material, a 19 G will be used. A maximum of 3 passes will be made using the alternate needle. The total number of passes with the 22 G needle and the 19 G needle is 6. Data will be collected about the procedure and the performance of the needles for each procedure.
22 gauge needle liver biopsy
EUS will be performed. Specimens obtained from each pass will be placed in a separate biopsy jar. If the third pass does not result in sufficient diagnostic material, a 19 G will be used. A maximum of 3 passes will be made using the alternate needle. The total number of passes with the 22 G needle and the 19 G needle is 6. Data will be collected about the procedure and the performance of the needles for each procedure.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
22 gauge needle liver biopsy
EUS will be performed. Specimens obtained from each pass will be placed in a separate biopsy jar. If the third pass does not result in sufficient diagnostic material, a 19 G will be used. A maximum of 3 passes will be made using the alternate needle. The total number of passes with the 22 G needle and the 19 G needle is 6. Data will be collected about the procedure and the performance of the needles for each procedure.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. Age ≥ 19 years
3. Willing to provide informed consent verbal or written.
Exclusion Criteria
2. Unable to safely undergo EUS for any reason
3. Coagulopathy (INR \>1.6, Thrombocytopenia with platelet count \<50,000/ml) for subjects on anti-coagulation therapy.
4. Unwilling or cognitively unable to provide informed consent verbal or written.
5. Pregnancy (confirmed with Standard of Care urine pregnancy test for all women with child-bearing potential only)
19 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
AdventHealth
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Muhammad Hasan, MD
Role: PRINCIPAL_INVESTIGATOR
Florida Hospital - Center for Interventional Endoscopy
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Center for Interventional Endoscopy - Florida Hospital
Orlando, Florida, United States
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Rockey DC, Caldwell SH, Goodman ZD, Nelson RC, Smith AD; American Association for the Study of Liver Diseases. Liver biopsy. Hepatology. 2009 Mar;49(3):1017-44. doi: 10.1002/hep.22742. No abstract available.
Kalambokis G, Manousou P, Vibhakorn S, Marelli L, Cholongitas E, Senzolo M, Patch D, Burroughs AK. Transjugular liver biopsy--indications, adequacy, quality of specimens, and complications--a systematic review. J Hepatol. 2007 Aug;47(2):284-94. doi: 10.1016/j.jhep.2007.05.001. Epub 2007 May 24.
Mathew A. EUS-guided routine liver biopsy in selected patients. Am J Gastroenterol. 2007 Oct;102(10):2354-5. doi: 10.1111/j.1572-0241.2007.01353_7.x. No abstract available.
Gleeson FC, Clayton AC, Zhang L, Clain JE, Gores GJ, Rajan E, Smyrk TC, Topazian MD, Wang KK, Wiersema MJ, Levy MJ. Adequacy of endoscopic ultrasound core needle biopsy specimen of nonmalignant hepatic parenchymal disease. Clin Gastroenterol Hepatol. 2008 Dec;6(12):1437-40. doi: 10.1016/j.cgh.2008.07.015. Epub 2008 Jul 26.
Dewitt J, McGreevy K, Cummings O, Sherman S, Leblanc JK, McHenry L, Al-Haddad M, Chalasani N. Initial experience with EUS-guided Tru-cut biopsy of benign liver disease. Gastrointest Endosc. 2009 Mar;69(3 Pt 1):535-42. doi: 10.1016/j.gie.2008.09.056.
Stavropoulos SN, Im GY, Jlayer Z, Harris MD, Pitea TC, Turi GK, Malet PF, Friedel DM, Grendell JH. High yield of same-session EUS-guided liver biopsy by 19-gauge FNA needle in patients undergoing EUS to exclude biliary obstruction. Gastrointest Endosc. 2012 Feb;75(2):310-8. doi: 10.1016/j.gie.2011.09.043.
Nakai Y, Samarasena JB, Iwashita T, Park DH, Lee JG, Hu KQ, Chang KJ. Autoimmune hepatitis diagnosed by endoscopic ultrasound-guided liver biopsy using a new 19-gauge histology needle. Endoscopy. 2012;44 Suppl 2 UCTN:E67-8. doi: 10.1055/s-0031-1291567. Epub 2012 Mar 6. No abstract available.
Maharaj B, Maharaj RJ, Leary WP, Cooppan RM, Naran AD, Pirie D, Pudifin DJ. Sampling variability and its influence on the diagnostic yield of percutaneous needle biopsy of the liver. Lancet. 1986 Mar 8;1(8480):523-5. doi: 10.1016/s0140-6736(86)90883-4.
Diehl DL, Johal AS, Khara HS, Stavropoulos SN, Al-Haddad M, Ramesh J, Varadarajulu S, Aslanian H, Gordon SR, Shieh FK, Pineda-Bonilla JJ, Dunkelberger T, Gondim DD, Chen EZ. Endoscopic ultrasound-guided liver biopsy: a multicenter experience. Endosc Int Open. 2015 Jun;3(3):E210-5. doi: 10.1055/s-0034-1391412. Epub 2015 Feb 27.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
1055744
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.