Combined Forward and Retroflexion Withdrawal in the Detection of Polyps and Adenoma During Colonoscopy
NCT ID: NCT03901651
Last Updated: 2021-06-02
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
203 participants
INTERVENTIONAL
2019-01-02
2021-01-01
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Previous studies described a 12-28% of miss-rate for all polyps, a 31% for hyperplastic polyps and 6-27% for adenomas, with a higher miss rate noted for smaller polyps. The lesion missing rate depends on several factors, such as the location on difficult areas to be evaluated with conventional colonoscopes (the proximal side of the ileocecal valve, haustral folds, flexures or rectal valves), a flat shape, an inadequate bowel preparation and inadequate endoscopy technique, a time-limited colonoscope withdrawal.
If the standard 140º angle of view colonoscope is used approximately 13% of the colonic surface is unevaluated. The incorporation of colonoscopes with a 170-degree wide angled could improve adenoma detection rate.
The introduction of high definition (HD) colonoscopes and visual image enhancement technologies, such as narrow band imaging (NBI, Olympus America, Center Valley, PA), I-SCAN™ (Pentax Medical, Montvale, NJ) and Fuji Intelligent Chromo-Endoscopy (FICE™, Fujinon Endoscopy, Wayne, NJ) have improved the lesion characterization; however, several studies have failed to prove an increase in the adenoma detection rates.
The Third Eye Retroscope (Avantis Medical Systems, Sunnyvale, CA) is a disposable retrograde viewing device advanced through the accessory channel of a standard colonoscope. It allows retrograde viewing behind colonic folds and flexures simultaneously with the forward view of the colon. Although it shows an increase in the adenoma detection rate by 11%-25%, it has many disadvantages. First, it requires a separate processor and the device is disposable, increasing the cost of the procedure. Second, it occupies the working channel of the colonoscope, limiting the ability to suction. Third, if a polyp is detected, the viewing device has to be removed in order to perform the polypectomy. Fourth, the optic is not high definition and finally, the endoscopist has to get used to visualizing and processing two simultaneous video streams from the colonoscopy and from the retroscope device.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Retroview™ Colonoscope and Lesion Detection Rate
NCT03155165
Inspection of the Colon Using a Retrograde Viewing Device for Detection of Colorectal Polyps
NCT04107376
Retroview Colonoscope for the Evaluation of Colon Mucosa Study
NCT02352233
Detection and Classification of Colon Polyps
NCT00825292
Retroflexion In The Ascending Colon Is A Costless Endoscopic Maneuver Increasing Adenoma Detection Rate
NCT04086706
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
This device offers many advantages, such as the ability to provide a high definition view of the proximal aspects of colonic folds, flexures, and valves with no additional equipment or device costs. The image quality is high definition and the colonoscope also incorporates the I-SCAN technology. The suction/work channel of the colonoscope is available for therapeutic procedures. Polypectomy can be performed with the colonoscope during retroflexion, without losing view of the polyp. The only disadvantages are the higher consumed withdrawal time because the additional retroflexed withdrawal to the standard withdrawal and that a small portion of the colon is obscured by the shaft of the colonoscope in retroflexion that may be the reason why combined standard withdrawal with retroflexed withdrawal has proved to be better than retroflexed withdrawal alone.
The aim of this study is to determinate the polyp and adenoma detection rate via performing a colonoscopy using a conventional scope with standard withdrawal (forward view) and a combined forward and retroflexed withdrawal technique using the RetroView™ colonoscope.
Lesion's dimensions and characteristics will be recorded to determine a difference between both techniques.
MATERIALS AND METHODS Setting: Instituto Ecuatoriano de Enfermedades Digestivas (IECED), Omni Hospital Academic Tertiary Center. We will include patients from January 2019 to November 2019. The study protocol and consent form has been approved by the Institutional Review Board of our institution and will be conducted according to the Declaration of Helsinki. Patients will provide written informed consent.
Intervention: endoscopic technique. Participants will be submitted to two colonoscopies on the same day. First, a standard colonoscopy will be performed using a conventional HD colonoscope with I-Scan (EC 3490LK, PENTAX, Montvale, NJ) that has a 13.2 mm tube diameter and a total length of 2023 mm). Then a second procedure, combining the standard forward view and retroflexed withdrawal will be performed using the Retroview™ colonoscope (EC34-i10TL, Pentax Medical, Montvale, NJ), that has an 11.6 mm tube diameter and 2023 mm length.
The endoscopy images will be seen on a 27-inch, flat panel, HD LCD monitor (Radiance™ ultra-SC-WU27-G1520 model). All participants will have the same colonic preparation with 4 liters of polyethylene glycol (PEG) the day before and bowel preparation will be evaluated using the Boston Bowel Preparation Scale.
Two endoscopists with proficiency in retroflexed withdrawal will perform the colonoscopies. Colonoscopies will be performed in a tandem, random manner. First one endoscopist will perform the conventional colonoscopy using standard withdrawal technique with standard colonoscopes and then the second endoscopist blinded to the first colonoscopy results will perform the second colonoscopy with the Retroview scope and combination withdrawal (retroflexed with standard withdrawal). The operator assigned to each colonoscopy will be chosen randomly. A minimum withdrawal time of 10 minutes will be required for each procedure. After the examination, endoscopist will fill a questionnaire describing each polyp and adenoma found, including the size and location. The withdrawal time spent in each procedure will be measured.
Statistical analysis: Baseline characteristics will be analyzed using Chi-square o Fisher Test for categorical variable and Mann-Whitney Test for continuous variables. If there is more than one polyp in one patient it will be considered individually for statistical purposes. A P value of less than 0.05 will be considered statistically significant. All the statistical analysis will be performed using R.
Limitations: The protocol will be performed in a single-center by six endoscopists. A lack of a control group because the intention is to compare two endoscopic techniques in the same setting.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NON_RANDOMIZED
PARALLEL
DIAGNOSTIC
SINGLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Standard colonoscopy
Patients submitted for screening, surveillance or diagnostic colonoscopy. A standard colonoscopy with forwarding viewing withdrawal technique. An HD colonoscope with I-scan technology will be used by one expert endoscopist.
Each polyp and adenoma will be recorded, including the size and location. Polyps will be removed before the second procedure.
Colonoscopy with standard colonoscope and forward withdrawal technique
A standard colonoscopy with forwarding viewing withdrawal technique. An HD colonoscope with I-scan technology will be used by one expert endoscopist.
Each polyp and adenoma will be recorded, including the size and location.
Retroview colonoscopy
The same group of patients. A second colonoscopy using a combined forward and retroflexed evaluation of the colonic mucosa. using the Retroview™ scope. The operator will be blind to the first colonoscopy findings.
The operator will record the polyps and adenoma encountered, describing the size and location.
Colonoscopy with Retroview scope combing forward and retroflexed withdrawal technique
Colonoscopy using a combined forward and retroflexed evaluation of the colonic mucosa. using the Retroview™ scope. The operator will be blind to the standard colonoscopy findings.
The operator will record the polyps and adenoma encountered, describing the size and location.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Colonoscopy with Retroview scope combing forward and retroflexed withdrawal technique
Colonoscopy using a combined forward and retroflexed evaluation of the colonic mucosa. using the Retroview™ scope. The operator will be blind to the standard colonoscopy findings.
The operator will record the polyps and adenoma encountered, describing the size and location.
Colonoscopy with standard colonoscope and forward withdrawal technique
A standard colonoscopy with forwarding viewing withdrawal technique. An HD colonoscope with I-scan technology will be used by one expert endoscopist.
Each polyp and adenoma will be recorded, including the size and location.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Colonoscopy indicated for colorectal cancer screening or surveillance
* Patients submitted for polypectomy
* Colonoscopy indicated for diagnostic purposes: anemia, abdominal pain, constipation, alteration of bowel habits.
Exclusion Criteria
* Pregnancy and/or nursing.
* Patients with past-medical history of cardiac, renal, hepatic or severe metabolic diseases
* Unable to tolerate sedation
* Severe uncontrolled coagulopathy
* Past surgical history of colonic resection, ileostomy or colostomy.
* Previous abdominal or pelvic radiation therapy.
* Patients with inflammatory bowel disease, polyposis syndrome or acute diverticulitis.
* Patients with high suspicion of colonic obstruction or history of prior obstruction.
* Patients with gastrointestinal bleeding.
* Inadequate bowel preparation. The bowel preparation will be evaluated using the Boston Bowel Preparation Scale. Patients with \< 2 points in at least one of the three segments of the colon will be excluded.
* Patients who after the beginning of the colonoscopy have to be suspended due to the inability to reach into the cecum because of unfavorable anatomy or impassable tumors/stenosis.
45 Years
80 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Instituto Ecuatoriano de Enfermedades Digestivas
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Carlos Robles-Medranda, MC
Role: PRINCIPAL_INVESTIGATOR
Instituto Ecuatoriano de Enfermedades Digestivas
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Ecuadorian Institute of Digestive Diseases
Guayaquil, Guayas, Ecuador
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
RV03-2019
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.