Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
30 participants
OBSERVATIONAL
2018-10-01
2019-12-15
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
For the extremity joints, goniometers (universal, bubble, digital) can also be used to measure active JPS. Depending on the device used and the extremity joint measured, reliability and measurement error of active movement goniometry can range widely and this should be carefully considered if goniometry is used to measure active JPS of extremity joints. Kinesthesia, can be measured by calculating the passive motion detection threshold of individuals.
The force sense (FS), commonly assessed using force reproduction, has also been used as a measure of proprioception. Assessing force reproduction by limb matching involves the use of a reference force, usually determined as a percentage of a Maximal Voluntary Isometric Contraction (MVIC), and attempting to replicate that force.
Proprioception can be decreased in those who suffer from knee injury. Because patients with severe degenerative joint disease often require total knee arthroplasty to relieve pain, improve stability, and restore function. Due to problems such as oedema, immobilization and subjective pain after surgery, it is difficult to evaluate proprioception with joint repositioning method. In such cases, the assessment of FS could be of particular interest in the knee region. FS can also be measured by the accuracy of reproducing a specific target force. For example, the pressure biofeedback device (PBD) used for assessing the cranio-cervical flexion test could be considered a method of assessing force sense in the cervical spine. The ability to hold steadily or the accuracy in achieving and maintaining a desired pressure can be used. However, for the knee region, there is no method to measure the force sense via a device that can be used in clinical practice.
The aim of this study was to establish a method for measuring FS that could be applied quickly and practically in the clinic, and to correlate the outcomes with surface electromyographic (EMG) muscle activation levels from M. Quadriceps femoris to demonstrate the applicability and objectivity of this method.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Test-Retest Reliability of Grip Force Sense for Proprioception Assessment
NCT07334808
Investigation of the Effects of Proprioceptive Exercises After Anterior Cruciate Ligament Surgery
NCT07333092
Effect of Kinesiotaping on Elbow Joint Proprioception
NCT05265780
Acute Effects of Heat, Cold and Stretching on Knee Proprioception and Vertical Jump
NCT06351709
Effects of Different Concentric and Eccentric Muscle Fatigue Protocols on the Knee Joint Position Sense
NCT06331221
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
CASE_ONLY
CROSS_SECTIONAL
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Case Group
Our study was performed with 30 healthy individuals at Hacettepe University, Faculty of Physical Therapy and Rehabilitation. The FS of the knee joint was measured with a Pressure Biofeedback Device (Stabilizer ™, Chattanooga Group Inc., Chattanooga, TN), a device similar to a sphygmomanometer. To correlate the outcomes of biofeedback device, simultaneously, a surface electromyography (EMG) data of M. Quadriceps femoris muscle activation levels from the individuals were recorded.
Test protocol for proprioceptive force sense in case group
* The FS in the knee region was measured by the pressure, biofeedback device (Stabilizer ™, Chattanooga Group Inc., Chattanooga, TN).
* Surface EMG device (Noraxon USA, Inc., Scottsdale, AZ) was used to measure activation levels of M. Vastus Medialis Obliquus (VMO), M. Vastus Lateralis (VL) and M. Rectus Femoris (RF) muscles. Due to the characteristics of the Bipolar Ag/AgCl surface electrodes, the distance between the electrodes was set to 1 cm and the electrode width to 2 cm. The electrode placement was determined according to the SENIAM (Surface ElectroMyoGraphy for the Non-Invasive Assessment of Muscles) criteria.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Test protocol for proprioceptive force sense in case group
* The FS in the knee region was measured by the pressure, biofeedback device (Stabilizer ™, Chattanooga Group Inc., Chattanooga, TN).
* Surface EMG device (Noraxon USA, Inc., Scottsdale, AZ) was used to measure activation levels of M. Vastus Medialis Obliquus (VMO), M. Vastus Lateralis (VL) and M. Rectus Femoris (RF) muscles. Due to the characteristics of the Bipolar Ag/AgCl surface electrodes, the distance between the electrodes was set to 1 cm and the electrode width to 2 cm. The electrode placement was determined according to the SENIAM (Surface ElectroMyoGraphy for the Non-Invasive Assessment of Muscles) criteria.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* without chronic neurologic problems
* without chronic rheumatological problems
* without cognitive problems
Exclusion Criteria
18 Years
35 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Hacettepe University
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Ceyhun Turkmen
Research Assistant
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Ceyhun Türkmen
Ankara, Altindag, Turkey (Türkiye)
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
GO 18/932
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.