Belgian-Italian Trial to Evaluate the Efficacy and Safety of Below The Knee (BTK) Treatment With the Luminor 14 Paclitaxel Coated Percutaneous Transluminal Angioplasty Balloon Catheter of iVascular
NCT ID: NCT03845543
Last Updated: 2024-11-08
Study Results
Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.
View full resultsBasic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
150 participants
INTERVENTIONAL
2018-11-28
2023-01-26
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Effectiveness of Paclitaxel-coated Luminor® Balloon Catheter Versus Uncoated Balloon Catheter in the Arteria Femoralis Superficialis
NCT02540018
Luminor Registry: Registry of the Results of Angioplasty With Drug-eluting Balloon (Paclitaxel) in the Treatment of Infrainguinal Occlusive Lesions and Restenosis From Prior Endovascular Procedures in This Sector.
NCT02458911
IN.PACT BTK Randomized Study to Assess Safety and Efficacy of IN.PACT 014 vs. PTA
NCT02963649
Paclitaxel Eluting Balloon and Conventional Balloon for In-Stent Restenosis of the Superficial Femoral Artery
NCT01083394
ILLUMENATE EU Randomized Clinical Trial
NCT01858363
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The patients will be selected based on the investigator's assessment, evaluation of the underlying disease and the eligibility criteria. The patient's medical condition should be stable, with no underlying medical condition which would prevent them from performing the required testing or from completing the study. Patients should be geographically stable, willing and able to cooperate in this clinical study, and remain available for long term follow-up. The patient is considered enrolled in the study after obtaining the patients informed consent, if there is full compliance with the study eligibility criteria and after successful guidewire passage through the study target lesion.
Prior to the index procedure the following will be collected: an informed consent for data collection, demographics, medical history, medication record, physical examination, clinical category of acute limb ischemia (Rutherford category), the resting ankle-brachial index (ABI), life quality and if applicable a wound assessment.
During the procedure the guidewire will cross the entire study lesion after which the lesion will be assessed through angiography. A pre-dilatation with a standard non-drug-coated balloon will be performed followed by a dilatation of the lesion with a Luminor-14 balloon (iVascular). If dilatation was not successful (\>30% stenosis, perforation, occlusive or flow limiting dissection) prolonged inflation should be attempted after which bail-out stenting with a non-drug-coated dedicated BTK stent is allowed in case of inadequate results.
The regular follow-up is necessary to monitor the condition of the patient and the results of the procedure. Patients will be invited on weekly follow-up, with special attention to wound healing status at each visit until the wound is completely healed. The other required follow-up visits are 1,6 and 12 months follow-ups. During these visit the following data will be collected: medication record, physical exam, wound assessment and healing status, quality of life, duplex ultrasound of target vessel and possible adverse events.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Luminor-14 paclitaxel eluting balloon
Pre-dilatation of 180 seconds with a standard non-drug-coated semi-compliant balloon followed by a dilatation with a Luminor-14 paclitaxel eluting balloon (3µg/mm² balloon surface).
Luminor-14 Paclitaxel eluting balloon
Patients will be treated with the Luminor-14 paclitaxel eluting balloon
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Luminor-14 Paclitaxel eluting balloon
Patients will be treated with the Luminor-14 paclitaxel eluting balloon
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Subject has been informed of and understands the nature of the study and provides signed informed consent to participate in the study. If the subject possesses the ability to understand and provide informed consent but due to physical inability, the subject cannot sign the informed consent form. An impartial witness may sign on behalf of the subject.
* Willing to comply with all required follow-up visits
* Rutherford Classification 5
* Significant degree of stenosis \>70% or chronic total occlusion (CTO)
* Infrapopliteal lesion: P3 to the ankle-joint level (not below-the-ankle (BTA)); full length lesions or tandem lesions are allowed
* Wound, Ischemia, foot Infection (WIfI) tissue loss grade 1-2 at baseline
* WIfI foot infection grade of 0-2 at baseline
* WIfI ischemia grade 2-3 at baseline
* Estimated life expectancy ≥ 1 year
* Multiple lesions can be treated if they are located in separate vessels per standard of care but only one (1) BTK vessel can be considered as the target lesion/vessel and need to be treated according the Clinical Investigation Protocol (CIP) guidelines.
* Target vessel should give direct or indirect run-off to the foot (clearly documented in a foot/BTA angiogram)
* Patients with in-flow lesions can be included if the lesions are treated successfully (residual stenosis ≤30%) with the same drug coated balloon (DCB) platform, bail-out stenting with a bare-metal stent (BMS).
* Successful pre-dilatation of the target lesion (≤30% residual stenosis)
Exclusion Criteria
* Acute limb ischemia, defined as symptom onset during less than 14 days prior to the index procedure
* Prior or planned above-the-ankle amputation to the target limb (this does not apply to ray amputation of ≤2 digits, simple digital amputations or ulcer debridement)
* Previous DCB treatment in target vessel 6 months prior to index procedure
* WIfI tissue loss grade 0 or 3 at baseline
* WIfI foot infection grade 3 at baseline
* WIfI ischemia grade 0-1 at baseline
* Any systemic infection or immunocompromised state. Patients with an ascending infection/deep foot infection or abscess/white blood count (WBC)≥12.000/or febrile state or C reactive protein (CRP)\>5mg/L
* Endovascular or surgical procedure (not including diagnostic procedures, planned simple digital amputation or wound debridement) to the target limb within 30 days after the index procedure
* Existing stent implant in the target vessel
* Use of alternative therapies: atherectomy, cutting/scoring balloons, laser, …
* Known coagulopathy, hypercoagulable state, bleeding diathesis, other blood disorder, or a platelet count less than 80.000/μL or greater than 500.000/μL
* Any subject in which antiplatelet, anticoagulant or thrombolytic therapy is contraindicated
* Myocardial infarction, coronary thrombolysis or angina less than 30 days prior to the index procedure
* History of stroke or transient ischemic attack (TIA) less than 90 days prior to the index procedure
* Known hypersensitivity or contraindication to nickel-titanium alloy (Nitinol)
* Has other comorbidities that, in the opinion of the investigator, would preclude them from receiving this treatment and/or participating in study-required follow-up
* Patients on haemodialysis
* Known hypersensitivity or allergy to contrast agents that cannot be medically managed
* Known hypersensitivity or allergy to heparin, aspirin, paclitaxel, clopidogrel or other antiplatelet/anticoagulant therapies
* Inadequate inflow lesion treatment (\>30% residual stenosis)
* Inadequate result of pre-dilatation (\>30% residual stenosis)
* Inadequate run-off to the foot
* Bilateral BTK enrolment in this study
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
ID3 Medical
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Koen Deloose, MD
Role: STUDY_DIRECTOR
ID3 Medical
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
OLV Ziekenhuis Aalst
Aalst, Oost-Vlaanderen, Belgium
Imelda Hospital
Bonheiden, , Belgium
A.Z. Sint-Blasius
Dendermonde, , Belgium
Z.O.L.
Genk, , Belgium
AZ Groeninge
Kortrijk, , Belgium
Regionaal Ziekenhuis Heilig Hart
Tienen, , Belgium
Policlinico Abano Terme
Abano Terme, Padua, Italy
IRCCS Policlinico San Donato
San Donato, , Italy
Hospital Univ. Germans Trias I Pujol
Badalona, , Spain
Countries
Review the countries where the study has at least one active or historical site.
Provided Documents
Download supplemental materials such as informed consent forms, study protocols, or participant manuals.
Document Type: Study Protocol and Statistical Analysis Plan
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
BIBLIOS-Luminor14BTK
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.