Analgesic Effect of Low Intensity Laser in Patients With Pulpitis of Mandibular Molars.

NCT ID: NCT03553407

Last Updated: 2019-03-13

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

UNKNOWN

Clinical Phase

NA

Total Enrollment

75 participants

Study Classification

INTERVENTIONAL

Study Start Date

2018-03-01

Study Completion Date

2020-06-01

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The present study has the objective of evaluating whether the previous therapy with low intensity laser, through its analgesic effect, can promote a greater comfort specifically for patient with pulpitis in mandibular molars. 75 patients with pain from mandibular molar pulpitis will be selected for this study (randomized and double blind) and divided into 3 groups (n = 25): Group 1 - Pulse Laser (880nm, 30mW, 3,6J / cm², 25Hz) ; Group 2 - Continuous Laser (880nm; 30mW; 3.6J / cm²); Group 3 - Placebo. The efficacy of the laser will be assessed using the VAS scale 10 minutes after the laser application, immediately before the blockade is performed.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Anxiety, pain and discomfort are situations of great stress in the daily routine of clinical practice, and especially in the practice of the dental emergency sector. Several studies have concluded that low-intensity laser therapy has been shown to be effective in pain management. However, the majority report the use of laser in the treatment of chronic pain, few studies show its application in acute pain and only one study evaluated the effect of low laser on acute pain of pulp inflammation, but with other parameters. In addition, because of the inflammatory process and several factors of unknown origin, the anesthetic agent can not always promote complete analgesia, especially when faced with mandibular molars. Therefore, the present study has the objective of evaluating whether the previous therapy with low intensity laser, through its analgesic effect, can promote a greater comfort specifically for this type of patient. 75 patients with pain from mandibular molar pulpitis will be selected for this study (randomized and double blind) and divided into 3 groups (n = 25): Group 1 - Pulse Laser (880nm, 30mW, 3,6J / cm², 25Hz) ; Group 2 - Continuous Laser (880nm; 30mW; 3.6J / cm²); Group 3 - Placebo. The pain will be evaluated by means of an VAS score in 6 different times: initial pain, immediately after and 10 minutes after irradiation with the laser, 10 minutes after inferior alveolar nerve block (IANB), during conventional endodontic treatment, after the end of the procedure. (T0, T1, T1 ', T2, T3 and T4). The efficacy of the laser application will be assessed using the VAS scale 10 minutes after the laser application, immediately before the blockade is performed. The use of the laser will be considered effective if the patient reports a reduction in the VAS scale of 2 points, between the initial moment and 10 minutes after the laser application. Analgesia will be evaluated during the pulpectomy procedure with the use of the verbal analogue scale 0 to 3. Analgesic effect will be considered if the professional can finish the procedure without the patient reporting 2 or 3 on this scale. The data obtained between the different groups and schedules will be compared statistically, and the statistical test chosen will depend on the normality of the data. The data obtained between the different groups and times will be compared statistically, and the statistical test chosen will depend on the normality of the data.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Pulpitis - Irreversible

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

TREATMENT

Blinding Strategy

DOUBLE

Participants Investigators

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Low Level Laser - Pulse

In this group the patient will receive the following laser protocol: 880nm, 30mW, 3.6 J / cm², 25 Hz

Group Type EXPERIMENTAL

Low Level Laser - Pulse

Intervention Type DEVICE

The laser will be applied at a single point in contact, perpendicular to the surface of the tooth in a region that presents healthy enamel, towards the pulp chamber. The laser chosen was the low power diode laser with the following protocols: Group 1 (880nm, 30mW, 3.6 J / cm², 25 Hz) and Group 2 (880nm, 30mW, 3.6 J / cm²), after 10 minutes we will ask to the patient again from 0 to 3 the level of pain, to then proceed to the anesthetic phase.

Low Level Laser - continuous

In this group the patient will receive the following laser protocol: 880nm, 30mW, 3.6 J / cm²

Group Type EXPERIMENTAL

Low Level Laser - continuous

Intervention Type DEVICE

The laser will be applied at a single point in contact, perpendicular to the surface of the tooth in a region that presents healthy enamel, towards the pulp chamber. The laser chosen was the low power diode laser with the following protocols: Group 1 (880nm, 30mW, 3.6 J / cm², 25 Hz) and Group 2 (880nm, 30mW, 3.6 J / cm²), after 10 minutes we will ask to the patient again from 0 to 3 the level of pain, to then proceed to the anesthetic phase.

Low Level Laser - Placebo

In this group the patient will receive the protocol with the equipment turned off.

Group Type PLACEBO_COMPARATOR

Low Level Laser - placebo

Intervention Type DEVICE

placebo will be applied at a single point in contact, perpendicular to the surface of the tooth in a region that presents healthy enamel, towards the pulp chamber. The laser chosen was the low power diode laser with the following protocols: Group 1 (880nm, 30mW, 3.6 J / cm², 25 Hz) and Group 2 (880nm, 30mW, 3.6 J / cm²), after 10 minutes we will ask to the patient again from 0 to 3 the level of pain, to then proceed to the anesthetic phase.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Low Level Laser - Pulse

The laser will be applied at a single point in contact, perpendicular to the surface of the tooth in a region that presents healthy enamel, towards the pulp chamber. The laser chosen was the low power diode laser with the following protocols: Group 1 (880nm, 30mW, 3.6 J / cm², 25 Hz) and Group 2 (880nm, 30mW, 3.6 J / cm²), after 10 minutes we will ask to the patient again from 0 to 3 the level of pain, to then proceed to the anesthetic phase.

Intervention Type DEVICE

Low Level Laser - continuous

The laser will be applied at a single point in contact, perpendicular to the surface of the tooth in a region that presents healthy enamel, towards the pulp chamber. The laser chosen was the low power diode laser with the following protocols: Group 1 (880nm, 30mW, 3.6 J / cm², 25 Hz) and Group 2 (880nm, 30mW, 3.6 J / cm²), after 10 minutes we will ask to the patient again from 0 to 3 the level of pain, to then proceed to the anesthetic phase.

Intervention Type DEVICE

Low Level Laser - placebo

placebo will be applied at a single point in contact, perpendicular to the surface of the tooth in a region that presents healthy enamel, towards the pulp chamber. The laser chosen was the low power diode laser with the following protocols: Group 1 (880nm, 30mW, 3.6 J / cm², 25 Hz) and Group 2 (880nm, 30mW, 3.6 J / cm²), after 10 minutes we will ask to the patient again from 0 to 3 the level of pain, to then proceed to the anesthetic phase.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* ASA I patients, according to the classification of the American Society of Anesthesiology (ASA)
* 18 and 50 years
* Systolic pressure below 140 mmHg and diastolic below 90 mmHg and heart rate between 70 - / + 20 beats / minute
* Pulpectomy in the first and / or lower second molars, which has at least one adjacent molar tooth and a contralateral canine; or absence of deep cavities, extensive restorations, advanced periodontal disease and no history of trauma or sensitivity.

Exclusion Criteria

* Patients with a history of sensitivity to local anesthetics and sulfur
* Pregnant or suspected of pregnancy
* Users of medications that may interact with the local anesthetic, such as, anxiolytics, antidepressants, antipsychotics, β-blockers and antihistaminic agents
* Patients with septic process near the injection site
* Patients under orthodontic treatment
* Patients with heart disease, neurological disease, hyperthyroidism and diabetes; drug users.
Minimum Eligible Age

18 Years

Maximum Eligible Age

50 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

University of Sao Paulo

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Isabel Peixoto Tortamano

professor of the department of stomatology of the university of sao paulo

Responsibility Role PRINCIPAL_INVESTIGATOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

University of Sao Paulo

São Paulo, , Brazil

Site Status RECRUITING

Countries

Review the countries where the study has at least one active or historical site.

Brazil

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Isabel F Tortamano

Role: CONTACT

551130918030

Facility Contacts

Find local site contact details for specific facilities participating in the trial.

Isabel P Tortamano, Phd

Role: primary

+55 11 30917813

References

Explore related publications, articles, or registry entries linked to this study.

Ramalho KM, de Souza LM, Tortamano IP, Adde CA, Rocha RG, de Paula Eduardo C. A randomized placebo-blind study of the effect of low power laser on pain caused by irreversible pulpitis. Lasers Med Sci. 2016 Dec;31(9):1899-1905. doi: 10.1007/s10103-016-2068-7. Epub 2016 Oct 1.

Reference Type RESULT
PMID: 27696017 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

Laser

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.