Analgesic Effect of Low Intensity Laser in Patients With Pulpitis of Mandibular Molars.
NCT ID: NCT03553407
Last Updated: 2019-03-13
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
NA
75 participants
INTERVENTIONAL
2018-03-01
2020-06-01
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Effect of Low Power Laser in Tooth Pain Modulation Caused by Irreversible Inflammation
NCT02169102
Intraligamentary vs Inferior Alveolar Nerve Block for Pulpitis: A Randomized Clinical Trial
NCT07130760
The Effect of Photobiomodulation Using Low-Level Diode Laser Therapy on Postoperative Pain in Symptomatic Lower Molar Teeth With Irreversible Pulpitis and Apical Periodontitis; a Randomized Controlled Clinical Trial
NCT06396130
Clinical, Radiographic and Patient Acceptance Evaluation of LASER Compared to Formocresol Pulpotomies inPrimary Molars
NCT06200818
Diode Laser Pulpotomy of Mature Permanent Molars With Irreversible Pulpitis
NCT05427851
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
TREATMENT
DOUBLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Low Level Laser - Pulse
In this group the patient will receive the following laser protocol: 880nm, 30mW, 3.6 J / cm², 25 Hz
Low Level Laser - Pulse
The laser will be applied at a single point in contact, perpendicular to the surface of the tooth in a region that presents healthy enamel, towards the pulp chamber. The laser chosen was the low power diode laser with the following protocols: Group 1 (880nm, 30mW, 3.6 J / cm², 25 Hz) and Group 2 (880nm, 30mW, 3.6 J / cm²), after 10 minutes we will ask to the patient again from 0 to 3 the level of pain, to then proceed to the anesthetic phase.
Low Level Laser - continuous
In this group the patient will receive the following laser protocol: 880nm, 30mW, 3.6 J / cm²
Low Level Laser - continuous
The laser will be applied at a single point in contact, perpendicular to the surface of the tooth in a region that presents healthy enamel, towards the pulp chamber. The laser chosen was the low power diode laser with the following protocols: Group 1 (880nm, 30mW, 3.6 J / cm², 25 Hz) and Group 2 (880nm, 30mW, 3.6 J / cm²), after 10 minutes we will ask to the patient again from 0 to 3 the level of pain, to then proceed to the anesthetic phase.
Low Level Laser - Placebo
In this group the patient will receive the protocol with the equipment turned off.
Low Level Laser - placebo
placebo will be applied at a single point in contact, perpendicular to the surface of the tooth in a region that presents healthy enamel, towards the pulp chamber. The laser chosen was the low power diode laser with the following protocols: Group 1 (880nm, 30mW, 3.6 J / cm², 25 Hz) and Group 2 (880nm, 30mW, 3.6 J / cm²), after 10 minutes we will ask to the patient again from 0 to 3 the level of pain, to then proceed to the anesthetic phase.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Low Level Laser - Pulse
The laser will be applied at a single point in contact, perpendicular to the surface of the tooth in a region that presents healthy enamel, towards the pulp chamber. The laser chosen was the low power diode laser with the following protocols: Group 1 (880nm, 30mW, 3.6 J / cm², 25 Hz) and Group 2 (880nm, 30mW, 3.6 J / cm²), after 10 minutes we will ask to the patient again from 0 to 3 the level of pain, to then proceed to the anesthetic phase.
Low Level Laser - continuous
The laser will be applied at a single point in contact, perpendicular to the surface of the tooth in a region that presents healthy enamel, towards the pulp chamber. The laser chosen was the low power diode laser with the following protocols: Group 1 (880nm, 30mW, 3.6 J / cm², 25 Hz) and Group 2 (880nm, 30mW, 3.6 J / cm²), after 10 minutes we will ask to the patient again from 0 to 3 the level of pain, to then proceed to the anesthetic phase.
Low Level Laser - placebo
placebo will be applied at a single point in contact, perpendicular to the surface of the tooth in a region that presents healthy enamel, towards the pulp chamber. The laser chosen was the low power diode laser with the following protocols: Group 1 (880nm, 30mW, 3.6 J / cm², 25 Hz) and Group 2 (880nm, 30mW, 3.6 J / cm²), after 10 minutes we will ask to the patient again from 0 to 3 the level of pain, to then proceed to the anesthetic phase.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* 18 and 50 years
* Systolic pressure below 140 mmHg and diastolic below 90 mmHg and heart rate between 70 - / + 20 beats / minute
* Pulpectomy in the first and / or lower second molars, which has at least one adjacent molar tooth and a contralateral canine; or absence of deep cavities, extensive restorations, advanced periodontal disease and no history of trauma or sensitivity.
Exclusion Criteria
* Pregnant or suspected of pregnancy
* Users of medications that may interact with the local anesthetic, such as, anxiolytics, antidepressants, antipsychotics, β-blockers and antihistaminic agents
* Patients with septic process near the injection site
* Patients under orthodontic treatment
* Patients with heart disease, neurological disease, hyperthyroidism and diabetes; drug users.
18 Years
50 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
University of Sao Paulo
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Isabel Peixoto Tortamano
professor of the department of stomatology of the university of sao paulo
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
University of Sao Paulo
São Paulo, , Brazil
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
References
Explore related publications, articles, or registry entries linked to this study.
Ramalho KM, de Souza LM, Tortamano IP, Adde CA, Rocha RG, de Paula Eduardo C. A randomized placebo-blind study of the effect of low power laser on pain caused by irreversible pulpitis. Lasers Med Sci. 2016 Dec;31(9):1899-1905. doi: 10.1007/s10103-016-2068-7. Epub 2016 Oct 1.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
Laser
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.