CT Guided WiSE-CRT

NCT ID: NCT03495505

Last Updated: 2022-03-29

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

11 participants

Study Classification

INTERVENTIONAL

Study Start Date

2018-08-31

Study Completion Date

2021-05-05

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

This feasibility study will use CT scanning to identify the optimal location for placement of the WiSE-CRT system.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Heart failure (HF) is estimated to affect at least 10% of adults aged over 70 years old, with a 12-month all-cause mortality rate of 7% in stable patients. Cardiac resynchronisation therapy (CRT) is an important intervention for patients with severe left ventricular (LV) systolic impairment and helps to improve well-being and reduce morbidity and mortality. CRT is achieved by placing endocardial pacing leads into the right atrium and right ventricle and then placing a third pacing lead through the coronary sinus (CS) to enable epicardial LV pacing, thus achieving ventricular resynchronisation. Although this is a successful therapy, overall 30-40% of patients will fail to respond. Additionally, even in those eligible for CRT, approximately 8-10% of patients cannot have it implanted due to anatomical abnormalities such as venous occlusion, inappropriate CS targets, diffuse scar resulting in inappropriately high pacing thresholds or phrenic nerve stimulation. In these circumstances other avenues to achieve biventricular pacing needs to be sought.

The wireless CRT system (WiSE-CRT, EBR Systems) has been developed to overcome these issues. It uses an endocardial LV electrode to achieve biventricular pacing negating the need to implant a pacing lead through the CS. There are several advantages of endocardial LV pacing such as a greater selection of pacing sites, possibility of lower pacing outputs compared with conventional leads in the CS and it appears to be a more physiological way to pace. The WiSE-CRT system is used in conjunction with a single or dual-chamber pacemaker and is made up of several components. A transmitter is implanted subcutaneously, attached to a battery. This detects right ventricular pacing from the co-implant and then delivers ultrasonic energy which is received by an electrode placed in the LV endocardium to enable biventricular pacing. The transmitter must be placed in a position with an adequate "acoustic window," which requires a line from the transmitter to the LV that is free of significant tissue or bone. Additionally, the endocardial electrode must be placed in close proximity to the transmitter. In a study of 35 patients, the WiSE-CRT system was successful implanted in 97.1% of cases, with 97% achieving biventricular pacing at 1 month and 84.8% showing an improvement in the clinical composite score at 6 months. These results are particularly encouraging given the device was used in patients who had failed conventional CRT, representing a difficult patient group.

The major advantage of the WiSE-CRT system is that the LV electrode can be placed anywhere within the ventricle. Studies have shown that patient outcomes are improved by pacing at a site which avoids ventricular scar and targets an area of latest mechanical activation. These sites will vary according to the aetiology underlying HF. In addition, using conventional fluoroscopy to guide pacing lead implants has been shown to be inaccurate when compared with computed tomography (CT). Our group have previously shown that magnetic resonance imaging (MRI) can be overlaid on fluoroscopic images to help guide epicardial pacing to a specific location and improve outcomes. Many patients undergoing a WiSE-CRT implant will be unable to have a MRI due to their previous pacemaker implant. However, guidance may still be achieved using CT scanning.

The proximity and orientation of the transmitter to the endocardial electrode is important in determining the battery life of the WiSE-CRT system. Yeh et al. showed that a large proportion of patients have at least two suitable acoustic windows for placement of the transmitter. This provides the operator with more opportunities to carefully select an ideal location. However, once implanted the endocardial electrode must be placed within the acoustic window which limits the number of sites the electrode can then be placed.

Identifying the best location for both the transmitter and endocardial electrode is essential to target the most viable myocardium and improve patient outcomes. Ideally this should be achieved before the patient has undergone any procedure since implanting the transmitter limits the potential locations for the electrode. We believe CT guidance can provide satisfactory information to optimise the location for both the transmitter and electrode which will increase the patient response rate and improve outcomes.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Heart Failure

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

20 patients will be recruited into this feasibility study with a 6 month follow-up. There will be no blinding nor randomisation.
Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

WiSE-CRT eligible

Patients need to meet all the inclusion and none of the exclusion criteria in order to be eligible for the study. All these patients will receive the WiSE-CRT implant.

Group Type EXPERIMENTAL

WiSE-CRT

Intervention Type DEVICE

Intervention will involve placement of the WISE-CRT system which consists of a transmitter, battery and electrode.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

WiSE-CRT

Intervention will involve placement of the WISE-CRT system which consists of a transmitter, battery and electrode.

Intervention Type DEVICE

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

Cardiac Resynchronisation Therapy Wireless Endocardial Pacing WICS device

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Age ≥18
* Ability to provide informed consent to participate and willing to comply with the clinical investigation plan and follow-up schedule.
* Patients with pre-existing permanent pacing systems in situ.
* Left ventricular systolic impairment with ejection fraction of \<45%
* Clinical symptoms of heart failure despite optimal medical therapy (NYHA II- IV)
* QRS duration \>120ms on surface ECG

Exclusion Criteria

* Creatinine clearance \<30mls/minute (GFR)
* Severe allergy to contrast medium or severe asthma/ COPD
* Life expectancy \<1 year
* Significant aortic valve disease or prosthesis
* Significant mitral regurgitation
* Significant peripheral vascular disease
* Contraindication to anticoagulation therapy
* Insufficient acoustic window to the LV as assessed from diagnostic transthoracic echocardiography
* Left atrial or ventricular thrombus
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

National Institute for Health Research, United Kingdom

OTHER_GOV

Sponsor Role collaborator

Guy's and St Thomas' NHS Foundation Trust

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Steven Niederer, DPhil

Role: PRINCIPAL_INVESTIGATOR

King's College London

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Guys and St Thomas' NHS Foundation Trust

London, , United Kingdom

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United Kingdom

References

Explore related publications, articles, or registry entries linked to this study.

Ponikowski P, Voors AA, Anker SD, Bueno H, Cleland JGF, Coats AJS, Falk V, Gonzalez-Juanatey JR, Harjola VP, Jankowska EA, Jessup M, Linde C, Nihoyannopoulos P, Parissis JT, Pieske B, Riley JP, Rosano GMC, Ruilope LM, Ruschitzka F, Rutten FH, van der Meer P; ESC Scientific Document Group. 2016 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure: The Task Force for the diagnosis and treatment of acute and chronic heart failure of the European Society of Cardiology (ESC)Developed with the special contribution of the Heart Failure Association (HFA) of the ESC. Eur Heart J. 2016 Jul 14;37(27):2129-2200. doi: 10.1093/eurheartj/ehw128. Epub 2016 May 20. No abstract available.

Reference Type BACKGROUND
PMID: 27206819 (View on PubMed)

Reddy VY, Miller MA, Neuzil P, Sogaard P, Butter C, Seifert M, Delnoy PP, van Erven L, Schalji M, Boersma LVA, Riahi S. Cardiac Resynchronization Therapy With Wireless Left Ventricular Endocardial Pacing: The SELECT-LV Study. J Am Coll Cardiol. 2017 May 2;69(17):2119-2129. doi: 10.1016/j.jacc.2017.02.059.

Reference Type BACKGROUND
PMID: 28449772 (View on PubMed)

Ypenburg C, van Bommel RJ, Delgado V, Mollema SA, Bleeker GB, Boersma E, Schalij MJ, Bax JJ. Optimal left ventricular lead position predicts reverse remodeling and survival after cardiac resynchronization therapy. J Am Coll Cardiol. 2008 Oct 21;52(17):1402-9. doi: 10.1016/j.jacc.2008.06.046.

Reference Type BACKGROUND
PMID: 18940531 (View on PubMed)

Miller MA, Neuzil P, Dukkipati SR, Reddy VY. Leadless Cardiac Pacemakers: Back to the Future. J Am Coll Cardiol. 2015 Sep 8;66(10):1179-89. doi: 10.1016/j.jacc.2015.06.1081.

Reference Type BACKGROUND
PMID: 26337997 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

239322

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Image Supported Lead Placement in CRT
NCT05053568 ACTIVE_NOT_RECRUITING NA
Cardiac Resynchronisation Study
NCT01213537 COMPLETED