Air-Q® SP Versus Williams Intubating Airway for Single-Operator FOI

NCT ID: NCT03247803

Last Updated: 2019-03-22

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

60 participants

Study Classification

INTERVENTIONAL

Study Start Date

2018-06-11

Study Completion Date

2019-03-08

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The air-Q and air-Q SP are commercially-available supraglottic airways (SGAs) that can be used for primary airway maintenance or as a conduit for FOI, as can be the Williams, Ovassapian, and Berman Intubating Airways. The air-Q products have the same overall geometrical design, but differ in their cuff inflating mechanisms, where the air-Q uses a traditional pilot balloon valve, while the air-Q SP utilizes a self-inflating cuff that dynamically adjusts according to the relative resistances to airflow between the patient's lungs and the device's cuff. The purpose of this study is to compare the single-operator intubation success using the air-Q SP versus the Williams Intubating Airway as a conduit for flexible bronchoscopic intubation (FBI) and to compare the single-operator intubation success using the air-Q SP versus the Williams Intubating Airway as a conduit for flexible bronchoscopic intubation. Both devices are commercially-available and being used in the study in accordance with their labeled intended use. The investigator envisage that the endpoint of the study will be single operator intubation success rate.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Despite the introduction of videolaryngoscopes, flexible bronchoscopic intubation (FBI), also known as fiberoptic intubation (FOI), remains a critical method for achieving tracheal intubation in patients with difficult airways. Unfortunately, however, FOI often requires two-operators for success. One operator is required to manipulate the flexible bronchoscope through the patient's upper airway and into their trachea, while the second operator applies one or more maneuvers (e.g., jaw thrust, anterior jaw lift, or lingual retraction) with or without the use of a commercially-available fiberoptic intubating airway.

Previous studies have demonstrated the effectiveness of the currently available FIAs, but also illustrate the frequent need for an assistant for successful FOI. In this study, an assistant performed a jaw lift and a chin lift in all subjects as well.

The air-Q and air-Q SP are commercially-available supraglottic airways (SGAs) that can be used for primary airway maintenance or as a conduit for FOI, as can be the Williams, Ovassapian, and Berman Intubating Airways. The air-Q products have the same overall geometrical design, but differ in their cuff inflating mechanisms, where the air-Q uses a traditional pilot balloon valve, while the air-Q SP utilizes a self-inflating cuff that dynamically adjusts according to the relative resistances to airflow between the patient's lungs and the device's cuff. In prior trials comparing the air-Q and air-Q SP with the two other commercially-available SGAs, the air-Q and air-Q SP bowl design provided a partial or full view of the vocal cords in 80-92% of subjects without requiring any additional airway maneuvers applied by an assistant (e.g., jaw thrust, anterior jaw lift, or lingual retraction) (Galgon, 2011; Galgon, 2015). Presumably, in these situations, successful tracheal intubation using the air-Q or air-Q SP could have been achieved by a single operator versus requiring one or more assistants. However, this potential performance advantage has not yet been tested. Therefore, the purpose of this study is to compare use of the air-Q SP against the WA for FBI performed by a single operator.

The air-Q SP, rather than the air-Q, is chosen for this study because its lack of a pilot balloon valve allows its stem to be easily shortened to ease device removal over the coaxially placed tracheal tube. The WA is chosen for this study because it has performed best in past trials and is the airway routinely used by the study principal investigator (PI) for FBI. Both devices are commercially-available and being used in the study in accordance with their labeled intended use.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Intubation; Difficult or Failed Laryngeal Masks

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Adult patients presenting for a surgical or interventional procedure requiring general anesthesia and tracheal intubation, who do not meet any of the study exclusion criteria, and who give their informed consent, will be randomly allocated to receive either an air-Q SP or Williams Intubating Airway as a conduit to aid flexible bronchoscopic intubation.
Primary Study Purpose

TREATMENT

Blinding Strategy

DOUBLE

Participants Outcome Assessors
Each study subject will be blinded to the study device they receive; however, the anesthesia provider will not be blinded to the study device and will have access to all monitors deemed appropriate by the primary anesthesia team caring for the subject.

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Air-Q SP

air-Q Self-Pressurizing intubating Laryngeal Airway, sizes 3.5 and 4.5 (Mecury Medical, Clearwater, FL, USA)

Group Type EXPERIMENTAL

air-Q® SP

Intervention Type DEVICE

air-Q SP placement for airway maintenance,

Williams Intubating Airway

Airway Intubator, Williams, Adult Female, Single Use, Molded Surlyn Plastic, 9 cm or Airway Intubator, Williams, Adult Male, Single Use, Molded Surlyn Plastic, 10 cm

Group Type EXPERIMENTAL

Williams Airway Intubator (WA)

Intervention Type DEVICE

WA is placed in subject's oropharynx. If the vocal cords are not in view at the end of the WA, the operator may ask an assistant to perform an airway maneuver (e.g., jaw thrust, anterior jaw lift, or lingual traction) to attempt to bring the vocal cords into view

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

air-Q® SP

air-Q SP placement for airway maintenance,

Intervention Type DEVICE

Williams Airway Intubator (WA)

WA is placed in subject's oropharynx. If the vocal cords are not in view at the end of the WA, the operator may ask an assistant to perform an airway maneuver (e.g., jaw thrust, anterior jaw lift, or lingual traction) to attempt to bring the vocal cords into view

Intervention Type DEVICE

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

air-Q SP placement for airway maintenance WA is placed in subject's oropharynx.

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

1. Adult patients (≥18 years);
2. The patient is scheduled for an elective surgery or procedure that will take place in the UWHC main operating room, outpatient surgical center, or ambulatory procedure center; and
3. The patient's primary anesthesia care team has planned for general anesthesia with orotracheal intubation for airway maintenance.

Exclusion Criteria

1. The patient is \< 18 years of age;
2. The patient is non-English speaking;
3. The patient is known or believed to be pregnant;
4. The patient is a prisoner;
5. The patient has impaired decision-making capacity;
6. The patient is at increased risk for aspiration, including non-fasted or emergency surgery, and cases of uncontrolled gastroesophageal reflux disease, hiatal hernia, gastroparesis, esophageal dysmotility, prior esophagectomy, and/or emesis within twenty-four hours of the surgery or procedure;
7. The patient has limited mouth opening or oropharyngeal anatomy making successful placement of the study airway conduit unlikely;
8. The patient has airway exam features, a medical condition, or a past airway management history, which prompts the attending anesthesiologist to plan to maintain spontaneous ventilation during tracheal intubation;
9. The patient pre-operatively is requiring supplemental oxygen;
10. The patient has moderate to severe cardiac disease, as evidenced by a left ventricular ejection fraction of ≤ 50% on the most recent echocardiogram, severe aortic valve stenosis, atrial fibrillation with a resting pre-operative heart rate of ≥ 90 beats per minute, and/or known, multi-vessel coronary artery, managed conservatively with medical management or by intervention with multiple coronary artery stents or coronary bypass grafting; and
11. The patient has an allergy to glycopyrrolate.
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

University of Wisconsin, Madison

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Richard E Galgon, MD, MS

Role: PRINCIPAL_INVESTIGATOR

Department of Anesthesiology,University of Wisconsin, Madison, Wisconsin, United States, 53792

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

University of Wisconsin Hopital and Clinics

Madison, Wisconsin, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

References

Explore related publications, articles, or registry entries linked to this study.

Galgon RE, Schroeder KM, Han S, Andrei A, Joffe AM. The air-Q((R)) intubating laryngeal airway vs the LMA-ProSeal(TM) : a prospective, randomised trial of airway seal pressure. Anaesthesia. 2011 Dec;66(12):1093-100. doi: 10.1111/j.1365-2044.2011.06863.x. Epub 2011 Aug 22.

Reference Type BACKGROUND
PMID: 21880031 (View on PubMed)

Related Links

Access external resources that provide additional context or updates about the study.

https://www.ncbi.nlm.nih.gov/pubmed/21880031?dopt=Abstract

Galgon RE, Schroeder KM, Han S, et al. The air-Q(®) intubating laryngeal airway vs the LMA-ProSeal(TM) : a prospective, randomised trial of airway seal pressure. Anaesthesia. 2011 Dec;66(12):1093-100.

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

2017-0542

Identifier Type: -

Identifier Source: org_study_id

More Related Trials