Comparison Between Contact Force Guided and Blinded Strategy on PV Isolation in AF Patients

NCT ID: NCT02924181

Last Updated: 2020-03-18

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

60 participants

Study Classification

INTERVENTIONAL

Study Start Date

2015-06-30

Study Completion Date

2018-10-11

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Pulmonary vein (PV) isolation is very important in atrial fibrillation (AF) catheter ablation. PV reconnection is one of the main reasons in AF recurrence. Contact force-sensing catheter is a new catheter which has valuable tools to monitor and increase the efficacy of PV isolation. Previous paper reported the efficacy of contact force-sensing catheter on immediate PV isolation and outcome. However, there might be confounding factor as inter-individual variation. Therefore, we would like to compare the efficacy of contact force-sensing catheter within same patient but different veins.

In this study, we would like to confirm the efficacy of contact force-sensing catheter on immediate PV isolation outcome within same patient. This study randomized the right or left PVs whether to use the contact force-sensing function or not. The study design will minimize the inter-individual variation on evaluating the efficacy of contact force-sensing catheter on immediate PV isolation.

Also, in patients who had recurred AF or AT, we would like to evaluate the long-term efficacy of contact force-sensing catheter on PV isolation.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Sixty patients will be randomized to select right or left pulmonary veins whether to apply contact force-guided ablation or contact force-blinded ablation strategy. Each PV will be ablated with same contact force-sensing catheter (Thermocool Smart Touch Catheter, Biosense Webster Inc. CA). The PV (right or left) which will be randomized to contact force-sensing PV or blind PV. Contact force-sensing PV will be ablated guided by contact force, whereas the blind PVs will be ablated without contact force-sensing information. The change of impedance, total ablation and time to ablate PV will be collected and analysed according to contact force-sensing strategy. After exit and entrance block by conventional method, dormant conduction will be evaluated by using adenosine. The proportion of dormant conduction will be compared between contact force-sensing guided or blinded strategy.

During 1-year follow up, patients who recurred AF or AT will be undergo second ablation procedure. In these patients, PV reconnection rate will be evaluated by a duodecapolar lasso circular mapping catheter. We would like to know whether PVs which have ablated with contact force-sensing information at index procedure have less reconnection than those which was ablated without contact force-sensing information.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Atrial Fibrillation

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Lt PV CF guided/rt PV CF blinded

Fifteen patients will be allocated to this group. Left side pulmonary veins isolation will be performed with contact force information guidance. Then, right side pulmonary veins isolation will be performed without contact force information (using same catheter named SmartTouch Catheter).

Group Type ACTIVE_COMPARATOR

SmartTouch Catheter

Intervention Type DEVICE

Pulmonary vein (PV) isolation guided by CF information

Lt PV CF blinded/rt PV CF guided

Fifteen patients will be allocated to this group. Left side pulmonary veins isolation will be performed without contact force information (using same catheter named SmartTouch Catheter).Then, right side pulmonary veins isolation will be performed with contact force information guidance.

Group Type ACTIVE_COMPARATOR

SmartTouch Catheter

Intervention Type DEVICE

Pulmonary vein (PV) isolation guided by CF information

Rt PV CF guided/lt PV CF blinded

Fifteen patients will be allocated to this group. Right side pulmonary veins isolation will be performed with contact force information guidance. Then, left side pulmonary veins isolation will be performed without contact force information (using same catheter named SmartTouch Catheter).

Group Type ACTIVE_COMPARATOR

SmartTouch Catheter

Intervention Type DEVICE

Pulmonary vein (PV) isolation guided by CF information

Rt PV CF blinded/lt PV CF guided

Fifteen patients will be allocated to this group. Right side pulmonary veins isolation will be performed without contact force information (using same catheter named SmartTouch Catheter). Then, left side pulmonary veins isolation will be performed with contact force information guidance.

Group Type ACTIVE_COMPARATOR

SmartTouch Catheter

Intervention Type DEVICE

Pulmonary vein (PV) isolation guided by CF information

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

SmartTouch Catheter

Pulmonary vein (PV) isolation guided by CF information

Intervention Type DEVICE

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

Contact force guided pulmonary vein isolation

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Patients with symptomatic paroxysmal atrial fibrillation (AF) who had failed with anti-arrhythmic agents.

Exclusion Criteria

* Patients who had previous ablation for AF
* Patients with symptomatic persistent AF
Minimum Eligible Age

18 Years

Maximum Eligible Age

80 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Keimyung University Dongsan Medical Center

OTHER

Sponsor Role collaborator

Seoul National University Hospital

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Eue-Keun Choi

Professor

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Eue-Keun Choi, MD, PhD

Role: PRINCIPAL_INVESTIGATOR

Seoul National University Hospital

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Seoul National University Hospital

Seoul, , South Korea

Site Status

Countries

Review the countries where the study has at least one active or historical site.

South Korea

References

Explore related publications, articles, or registry entries linked to this study.

Andrade JG, Monir G, Pollak SJ, Khairy P, Dubuc M, Roy D, Talajic M, Deyell M, Rivard L, Thibault B, Guerra PG, Nattel S, Macle L. Pulmonary vein isolation using "contact force" ablation: the effect on dormant conduction and long-term freedom from recurrent atrial fibrillation--a prospective study. Heart Rhythm. 2014 Nov;11(11):1919-24. doi: 10.1016/j.hrthm.2014.07.033. Epub 2014 Jul 25.

Reference Type RESULT
PMID: 25068575 (View on PubMed)

Natale A, Reddy VY, Monir G, Wilber DJ, Lindsay BD, McElderry HT, Kantipudi C, Mansour MC, Melby DP, Packer DL, Nakagawa H, Zhang B, Stagg RB, Boo LM, Marchlinski FE. Paroxysmal AF catheter ablation with a contact force sensing catheter: results of the prospective, multicenter SMART-AF trial. J Am Coll Cardiol. 2014 Aug 19;64(7):647-56. doi: 10.1016/j.jacc.2014.04.072.

Reference Type RESULT
PMID: 25125294 (View on PubMed)

Marijon E, Fazaa S, Narayanan K, Guy-Moyat B, Bouzeman A, Providencia R, Treguer F, Combes N, Bortone A, Boveda S, Combes S, Albenque JP. Real-time contact force sensing for pulmonary vein isolation in the setting of paroxysmal atrial fibrillation: procedural and 1-year results. J Cardiovasc Electrophysiol. 2014 Feb;25(2):130-7. doi: 10.1111/jce.12303. Epub 2013 Nov 6.

Reference Type RESULT
PMID: 24433324 (View on PubMed)

Reichlin T, Knecht S, Lane C, Kuhne M, Nof E, Chopra N, Tadros TM, Reddy VY, Schaer B, John RM, Osswald S, Stevenson WG, Sticherling C, Michaud GF. Initial impedance decrease as an indicator of good catheter contact: insights from radiofrequency ablation with force sensing catheters. Heart Rhythm. 2014 Feb;11(2):194-201. doi: 10.1016/j.hrthm.2013.10.048. Epub 2013 Oct 28.

Reference Type RESULT
PMID: 24177370 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

SNUH

Identifier Type: -

Identifier Source: org_study_id

More Related Trials