OneTouch Select® [Brand Name]Plus Blood Glucose Monitoring System(BGMS) Registration Study
NCT ID: NCT02810522
Last Updated: 2019-11-15
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
WITHDRAWN
NA
INTERVENTIONAL
2016-08-31
2017-03-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Investigational Product:
OneTouch Select® Plus test strips (test with OneTouch Select® Plus glucose meter)
Objectives:
1. Assess Lay User and Health Care Professional (HCP) fingertip test results obtained on OneTouch Select® Plus BGMS compared to a validated method (YSI 2300 glucose analyzer results), according to International Standards Organization( ISO) 15197:2003(E) section 8.0 and ISO 15197:2013(E)
2. Lay User System Use evaluation.
3. Assess the effectiveness of the instructions for use of OneTouch Select® Plus BGMS (Owner's booklet) and insert of test strips for the lay user.
Comparator(control) Product:
YSI 2300 glucose analyser
Acceptance Criteria:
User Performance of the OneTouch Select® Plus Blood Glucose Monitoring system(described as OneTouch Select Plus below) is met if the lay user and HCP results obtained with OneTouch Select Plus meet the requirement stated in section 7.4.1 of ISO () 15197:2003(E). Further to meet the requirements of ISO 15197:2013(E) , the lay user results obtained with OneTouch Select Plus should meet the requirements stated in section 8.2 of ISO 15197:2013(E). The effectiveness of instructions for use is met , if for each item on the Instructions for Use Questionnaire, the 90% lower confidence limit (90% LCL) for the correct response rate is equal to or greater than 70%.
Study Design and subject population:
This study is an open, non-randomized clinical evaluation and will be conducted at a minimum of 2 sites in China. At least 240 evaluable diabetic subjects who meet the enrolment criteria will participate in this evaluation.
Study procedures:
1. Each potential Subject (or legally authorized representative) reads and signs the Informed Consent Form, and receives a signed copy.
2. After completing an in-clinic familiarization session, the Subject lances a fingertip, obtains a drop of blood large enough for two meter tests, and performs a self-test using OneTouch Select Plus BGMS.
3. Study staff immediately performs a blood glucose test from the same blood drop with a second set of OneTouch Select Plus BGMS with the same lot of test strips.
4. Within 5 minutes of the Subject's self-lancing, study staff collects blood from the same finger puncture for hematocrit and reference plasma glucose testing (duplicate tests on the YSI 2300 performed by study staff).
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Effects of Novel Flash Glucose Monitoring System on Glycemic Control in Adult Patients With Type 1 Diabetes Mellitus
NCT03522870
Clinical Evaluation of Non-invasive Blood Glucose Meter
NCT06796322
The Effectiveness of Flash Glucose Monitoring System on Glycemic Control in Patients With New-onset Type 2 Diabetes
NCT04535830
OneTouch® Verio™Pro+ Blood Glucose Monitoring System Clinical Accuracy Study in China
NCT01795625
Effect of Continuous Glucose Monitoring System Alerts on Diabetes Management in the Hospital
NCT05941286
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NON_RANDOMIZED
DIAGNOSTIC
NONE
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
OneTouch Select® Plus Glucose Test Strips
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. Subject has a current diagnosis of type 1 or type 2 diabetes mellitus.
3. Subject is currently performing unassisted self-monitoring of blood glucose.
4. Subject agrees to sign two (2) copies each of the Subject Informed Consent Form.
5. Subject agrees to provide relevant demographic, medical history and diabetes management information and agrees to allow study staff access to medical records when necessary.
6. Subject can read and understand Chinese.
7. Subject agrees to complete all aspects of the study including at least one fingertip puncture, one retry in maximum may be performed if insufficient blood collected or an error message is obtained on the first attempt.
Exclusion Criteria
2. Subject has already participated in this study.
3. Subject is knowingly pregnant.
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Shanghai 6th People's Hospital
OTHER
Shanghai East Hospital
OTHER
Johnson & Johnson Medical, China
INDUSTRY
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
LFS-201601
Identifier Type: -
Identifier Source: org_study_id