Performance Evaluation of Blood Glucose Monitoring System Using ISO Study Design
NCT ID: NCT01575080
Last Updated: 2016-02-29
Study Results
Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.
View full resultsBasic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
102 participants
INTERVENTIONAL
2012-04-30
2012-04-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Evaluation of an Karajishi Contour Investigational Blood Glucose Monitoring System (ISO/FDA Study)
NCT02150109
Performance Evaluation of an Investigational Blood Glucose Monitoring System
NCT01598610
Performance Evaluation by the User of BGM Contour Care According to ISO 15197:2015
NCT06937736
Evaluation of an Karajishi TS Investigational Blood Glucose Monitoring System
NCT02041377
System Accuracy Evaluation of Karajishi Contour and Karajishi TS Blood Glucose Monitoring Systems Following ISO 15197:2013
NCT02358408
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
DIAGNOSTIC
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Intended Users of the Monitoring System
Untrained subjects with diabetes use Contour TS Blood Glucose Monitoring System.
Contour TS Blood Glucose Monitoring System
Untrained subjects with diabetes perform self Blood Glucose (BG) tests with capillary fingerstick blood and AST of the palm and forearm using the Contour TS Blood Glucose Monitoring System. All BG results are compared to a reference laboratory glucose method.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Contour TS Blood Glucose Monitoring System
Untrained subjects with diabetes perform self Blood Glucose (BG) tests with capillary fingerstick blood and AST of the palm and forearm using the Contour TS Blood Glucose Monitoring System. All BG results are compared to a reference laboratory glucose method.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Be 18 years of age or older
* Be able to speak, read and understand English and understand the Informed Consent document.
* Be willing to complete study procedures
Exclusion Criteria
* Infections or skin disorders at the puncture site (at the discretion of the site professional staff).
* Hemophilia, bleeding disorder, or clotting problems. Persons taking aspirin (81 mg or 325 mg) daily or Plavix® are not reason for exclusion.
* Physical (dexterity), visual, or neurological impairments that would make the person unable to perform testing with the BGM (at the discretion of the site professional staff).
* A condition, in the opinion of the Investigator, would put the subject at risk or influence the conduct of the study or interpretation of the results. The reason for exclusion will be documented by the professional staff.
* Previously participated in a blood glucose monitoring study using Contour TS system or use the Contour TS for personal use when monitoring blood glucose.
* Working for a competitive medical device company or having an immediate family member or someone who is not a family member but is living within the household of someone who works for such a company
* Working for a medical laboratory, hospital or other clinical setting that involves training on and clinical use of blood glucose monitors
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Ascensia Diabetes Care
INDUSTRY
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
David Simmons, MD
Role: PRINCIPAL_INVESTIGATOR
Ascensia Diabetes Care
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Bayer HealthCare LLC, Diabetes Care
Mishawaka, Indiana, United States
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
R&D-2011-2012-0.20
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.