Effects of Novel Flash Glucose Monitoring System on Glycemic Control in Adult Patients With Type 1 Diabetes Mellitus

NCT ID: NCT03522870

Last Updated: 2023-02-10

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

104 participants

Study Classification

INTERVENTIONAL

Study Start Date

2018-05-01

Study Completion Date

2022-06-19

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

This trial is a randomized, multi-center, parallel-group, efficacy and safety study with a 26-weeks follow- up(after 2-week recruitment). The study aims to: 1)compare the effects of novel flash glucose monitoring system (FGMS) and conventional Self Measurement of Blood Glucose (SMBG); and 2) optimize integrated management for glycaemic control in adult patients with type 1 diabetes who are sub-optimally controlled.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Subjects with Type 1 diabetes who meet criteria will be enrolled at up to eight clinical research sites in China. Subjects will be randomized to either flash glucose monitoring system(Freestyle Libre®;Abbott Diabetes Care,Witney, Oxon,UK) or conventional Self Measurement of Blood Glucose (Bayer®)alone at least three times per day. Primary outcome variable is the difference in HbA1c which will be analyzed in a central laboratory between baseline and the 26weeks follow-up. Secondary outcome variables such as time-in-range, frequency and duration of and hyperglycemic episodes etc. will be assessed at baseline (Week 0 to 2), Week 12-14 and Week 24-26 via professional continuous glucose system (Ipro2®; Medtronic). At the same time, demographic factors, clinical data, patient reported outcome (PROs) will be collected. Assessment of Adverse Events will occur via self-reporting at each visit and/or phone call. All patients will receive same ordinary diabetes education.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Diabetes Mellitus, Type 1

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

SUPPORTIVE_CARE

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Flash Glucose Monitoring System

People selected to this group will using flash glucose monitoring system continuously on Week 2-14 and Week 14-26.

Group Type EXPERIMENTAL

Flash glucose monitoring system

Intervention Type DEVICE

Using flash glucose monitoring system continuously on Week 2-14 and Week 14-26

SMBG

People selected to this group will using SMBG continuously on Week 2-14 and Week 14-26.

Group Type ACTIVE_COMPARATOR

SMBG

Intervention Type DEVICE

Performing SMBG at least three times/day on Week 2-14 and Week 14-26

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Flash glucose monitoring system

Using flash glucose monitoring system continuously on Week 2-14 and Week 14-26

Intervention Type DEVICE

SMBG

Performing SMBG at least three times/day on Week 2-14 and Week 14-26

Intervention Type DEVICE

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

Freestyle Libre®;Abbott Diabetes Care,Witney, Oxon,UK Capillary blood glucose tested by Bayer

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

1. Aged 18 years and older;
2. Diagnosed with type 1 diabetes with the criteria established by WHO in 1999,with duration more than 1 year;
3. Glycosylated Hemoglobin A1c concentration between 7% and 10%;
4. Self-monitor of blood glucose levels on a regular basis for 2 months previous( at least 3 times per day) and have willing to insist for at least 6 months
5. Using CSII or MDI for at least 3 months, stable diabetes medication regimen for 3 months prior to study entry(change in insulin ≦20%).
6. Willing to wear CGM;
7. Able to speak, read, and write Chinese

Exclusion Criteria

1. Having used CGM 3 months prior to study entry;
2. Had severe diabetic complications such as PDR in diabetic retinopathy and ESRD of diabetic nephropathy, assessed by investigators;
3. Receiving oral steroid therapy for any disorders and continuous use of paracetamol.
4. Had known allergy to medical-grade adhesives or CGM and its affiliated components;
5. Being pregnant or planning pregnancy (as demonstrated by a positive test at study entry);
6. Recent severe diseases like myocardial infarction,stroke,psychiatric diseases(historical/recent),malignant tumor, kidney disease(defined as eGFR\<45), dermatosis, decided by investigator.
7. Current participation in another investigational study (must have completed any previous studies at least 30 days prior to being enrolled in this study);
8. Currently abusing illicit drugs, alcohol, or prescription drugs;
9. Any condition that could impact reliability of the HbA1C measurement,(e.g.hemoglobinopathy, hemolytic anemia, chronic liver disease),decided by investigator.
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Sun Yat-sen University

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Jianping Weng

Professor,Principal Investigator,Department of Endocrinology and Metabolism,The Third Affiliated Hospital

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Xueying Zheng, MD

Role: PRINCIPAL_INVESTIGATOR

The First Affiliated Hospital of USTC

Jing Lu, PHD

Role: PRINCIPAL_INVESTIGATOR

Department of Endocrinology, Nanjing Drum Tower Hospital Affiliated to Nanjing University Medical School, Nanjing, China.

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

The Third Affiliated Hospital of Sun Yat-sen University

Guangzhou, Guangdong, China

Site Status

Countries

Review the countries where the study has at least one active or historical site.

China

References

Explore related publications, articles, or registry entries linked to this study.

Zhou Y, Deng H, Liu H, Yang D, Xu W, Yao B, Yan J, Weng J. Effects of novel flash glucose monitoring system on glycaemic control in adult patients with type 1 diabetes mellitus: protocol of a multicentre randomised controlled trial. BMJ Open. 2020 Dec 4;10(12):e039400. doi: 10.1136/bmjopen-2020-039400.

Reference Type BACKGROUND
PMID: 33277281 (View on PubMed)

Liu H, Yang D, Deng H, Xu W, Lv J, Zhou Y, Luo S, Zheng X, Liang H, Yao B, Qiu L, Wang F, Liu F, Yan J, Weng J. Impacts of glycemic variability on the relationship between glucose management indicator from iPro2 and laboratory hemoglobin A1c in adult patients with type 1 diabetes mellitus. Ther Adv Endocrinol Metab. 2020 Jun 8;11:2042018820931664. doi: 10.1177/2042018820931664. eCollection 2020.

Reference Type RESULT
PMID: 32551036 (View on PubMed)

Yan J, Zhou Y, Zheng X, Zheng M, Lu J, Luo S, Yang D, Deng H, Xu W, Bi Y, Bao W, Weng J. Effects of intermittently scanned continuous glucose monitoring in adult type 1 diabetes patients with suboptimal glycaemic control: A multi-centre randomized controlled trial. Diabetes Metab Res Rev. 2023 May;39(4):e3614. doi: 10.1002/dmrr.3614. Epub 2023 Feb 7.

Reference Type RESULT
PMID: 36670050 (View on PubMed)

Zhou Y, Mai X, Deng H, Yang D, Zheng M, Huang B, Xu L, Weng J, Xu W, Yan J. Discrepancies in glycemic metrics derived from different continuous glucose monitoring systems in adult patients with type 1 diabetes mellitus. J Diabetes. 2022 Jul;14(7):476-484. doi: 10.1111/1753-0407.13296. Epub 2022 Jul 21.

Reference Type RESULT
PMID: 35864804 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

2017YFC1309601

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Glucose Monitoring Comparison in Primary Care
NCT05222815 ACTIVE_NOT_RECRUITING NA