Comparison of Optic Nerve Head and Retinal Nerve Fiber Layer Parameters Derived From Two Different Methods of Scan Alignment

NCT ID: NCT02666144

Last Updated: 2016-04-26

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Total Enrollment

48 participants

Study Classification

OBSERVATIONAL

Study Start Date

2016-02-29

Study Completion Date

2016-03-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

This prospective, monocentric, non-invasive clinical study is designed to measure normal structural parameters of the optic nerve head, the peripapillary retinal nerve fiber layer, and the macula using the Heidelberg Spectralis OCT device. This study is conducted in normal, healthy volunteers and glaucoma patients. The main goal of the study is to provide an analysis of the comparability of these parameters between two different software versions and their respective method of scan centration on the optic disc center. The study will include at least 40 eyes of 40 subjects; 20 normal, healthy subjects and 20 glaucoma patients. All subjects will undergo Spectralis OCT imaging, biometric and ophthalmoscopic examination, and visual field testing in one single visit. Total study duration (first patient first visit to last patient last visit) is anticipated to be approximately 4 weeks.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Glaucoma

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

CASE_CONTROL

Study Time Perspective

PROSPECTIVE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Glaucoma

Spectralis OCT

Intervention Type DEVICE

Measurement of structural parameters of the optic nerve head (ONH), in particular, the neuroretinal rim of the ONH, and the peripapillary retinal nerve fiber layer.

Normal

Spectralis OCT

Intervention Type DEVICE

Measurement of structural parameters of the optic nerve head (ONH), in particular, the neuroretinal rim of the ONH, and the peripapillary retinal nerve fiber layer.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Spectralis OCT

Measurement of structural parameters of the optic nerve head (ONH), in particular, the neuroretinal rim of the ONH, and the peripapillary retinal nerve fiber layer.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Able and willing to undergo the test procedures, give consent, and to follow instructions
* Subjects that understand the nature of the trial
* Signed informed consent
* Age : 18 years or older
* For "normal subjects", "normal" means, there is no reason that would prevent imaging of the eye, therefore:
* Self-reported healthy eyes without prior intraocular surgery (except cataract surgery and laser in situ keratomileusis) and without clinically significant vitreal, retinal or choroidal diseases, diabetic retinopathy, or disease of the optic nerve (e.g. impacting central VA or RNFLT measurements as determined by the expertise of the investigator)
* Visual field GHT within normal limits
* For "glaucoma subjects": Early to advanced glaucoma according to existing medical charts and visual field GHT outside normal limits on at least two occasions during the testing.
* Refraction between +6 and -6 diopters spherical equivalent and astigmatism ≤ 2 diopters
* When both eyes are eligible, one randomly selected eye will be evaluated in the analysis

Exclusion Criteria

* Vulnerable subjects (as defined in ISO 14155 GCP)with the exception of employees of the site, and , if applicable, students of the respective university. Staff that is directly involved in the study is excluded from participation.
* subjects unable to read or write
* Unreliable visual field. The reliability indices should be used as guide as well as the perimetrist's notes.
* Unusable disc stereo photos.
* Inability to undergo the tests.
* Insufficient quality of Spectralis OCT images (this is not determined until after Spectralis OCT examination, and is an unusual circumstance).

Minimum requirements are:

* Retina completely included in image frame,
* Quality Score ≥ 20 in the stored ART mean images, and
* For ONH-R scan: Center position error ≤ 100 μm.
* Note: Inability of a subject to perform one of the two scan patterns or insufficient image quality in one scan pattern does not exclude the subject or eye from the study.
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Heidelberg Engineering GmbH

INDUSTRY

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Mitchell Dul, OD

Role: PRINCIPAL_INVESTIGATOR

State University of New York College of Optometry

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

S-2015-6

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

High Resolution Imaging OCT Study