Cardiac Output Measurement With NICCOMO and PiCCO Devices at Different PEEP Levels

NCT ID: NCT02572739

Last Updated: 2020-04-13

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

UNKNOWN

Total Enrollment

50 participants

Study Classification

OBSERVATIONAL

Study Start Date

2014-05-31

Study Completion Date

2021-03-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Thermodilution cardiac output measurement is a reliable method, but it is an invasive one. PiCCO device requires cannulation of central vein and peripheral artery. Impedance method requires only attachment of special electrodes. Non-invasive methods are less accurate. Aim of study is to assess accuracy and reliability of impedance method ( using NICCOMO device) in comparison of thermodilution method ( using PiCCO device) at different PEEP levels.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Echocardiography is performed prior to measurement to exclude patients with heart valve abnormalities.

Patients without spontaneous ventilation ( deeply unconscious, sedated or sedated and paralysed), ventilated with controlled mechanical ventilation mode with tidal volume 6-8 ml/ideal body weight, resulting in EtCO2 35-45 mmHg, with PiCCO catheters implemented have additionally NICCOMO device attached. Fraction of inspired oxygen (FiO2) is set to achieve saturation \>96% at positive end expiratory pressure (PEEP) 0 cmH2O.

Measurement of cardiac output are performed on expiration at PEEP 0, 5, 10, 15 20 cmH2O and at optimal PEEP (obtained from P-V curve). Simultaneously CO value from impedance device is noted. Other haemodynamic parameters, calculated by both devices are also noted - stroke volume (SV), stroke volume variation (SVV), Cardiac index (CI), systemic vascular resistance (SVR), systemic vascular resistance index (SVRI).

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Cardiovascular Diagnostic Techniques

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

CASE_ONLY

Study Time Perspective

CROSS_SECTIONAL

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

haemodynamics measuring

those with already implemented PICCO device get impedance device (NICCOMO) attached

PICCO

Intervention Type DEVICE

measurements based on thermodilution

NICCOMO

Intervention Type DEVICE

measurements based on impedance

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

PICCO

measurements based on thermodilution

Intervention Type DEVICE

NICCOMO

measurements based on impedance

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* critically ill patients
* patients on mechanical ventilation
* circulatory insufficiency (present or in the past) monitored with with PiCCO device

Exclusion Criteria

* morbid obesity,
* short neck,
* severe pneumonia,
* inability to NICCOMO electrodes attachment,
* massive tissue oedema,
* non-sinus cardiac rhythm,
* tachycardia,
* low cardiac output,
* septic shock,
* heart valve pathologies,
* severe atherosclerosis,
* aortic prosthesis,
* severe hypertension,
* extremes of height and weight,
* intraaortic pump
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Medical University of Gdansk

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Magdalena Wujtewicz

assistant professor

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Magdalena Wujtewicz

Role: PRINCIPAL_INVESTIGATOR

Department of Ophthalmology, Medical University of Gdańsk

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Medical University of Gdansk

Gdansk, , Poland

Site Status RECRUITING

Countries

Review the countries where the study has at least one active or historical site.

Poland

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Magdalena A Wujtewicz

Role: CONTACT

+48583493357

Radoslaw Owczuk

Role: CONTACT

605408140

Facility Contacts

Find local site contact details for specific facilities participating in the trial.

Magdalena A Wujtewicz

Role: primary

+48583493357

Radoslaw Owczuk

Role: backup

605408140

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

GUMed-Wu-002

Identifier Type: -

Identifier Source: org_study_id

More Related Trials