Pursed-lips Breathing and Dynamic Hyperinflation

NCT ID: NCT02203058

Last Updated: 2014-07-29

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

25 participants

Study Classification

INTERVENTIONAL

Study Start Date

2012-03-31

Study Completion Date

2013-07-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Background: Dynamic hyperinflation (DH) is an important factor leading to dyspnea and consequent limitations in functional capacity of chronic obstructive pulmonary disease (COPD) patients. It has not been completely elucidated whether pursed-lips breathing (PLB) is able to minimize DH and its effects on exercise tolerance in these patients. The aim of this study was to evaluate the acute effect of PLB on DH and functional capacity in patients with COPD.

Design: Randomized cross-over study. Setting: The study will be conducted in an outpatient pulmonary rehabilitation program in Florianópolis, Brazil.

Subjects: Twenty-five patients with COPD (16 men, mean age 64 (7) years, FEV1=41.7 (14.7)% predicted, BMI=27.6 (5.13)kg/m2).

Interventions: Patients will randomly perform two six-minute walk tests with and without PLB (6MWTPLB and 6MWTNon-PLB) and two Glittre-ADL tests with and without PLB (TGlittrePLB and TGlittreNon-PLB).

Main measures: At baseline and immediately after the tests, the inspiratory capacity (IC) will be assessed by the slow vital capacity (SVC) maneuver.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Pulmonary function testing Lung function will be tested using an Easy One spirometer (NDD Medical Technologies Inc., Zurich, Switzerland), and calibration checked before each evaluation. Spirometry will be performed in accordance with ATS/ERS standards (Miller et al, 2005). The predicted values will be calculated from the equations proposed by Pereira et al. (2007).

Inspiratory capacity (IC) measurement IC will be measured with the patient in the sitting position, using an Easy One portable spirometer (NDD Medical Technologies Inc., Zurich, Switzerland), before and immediately after the tests, by the slow vital capacity maneuver starting from a stable end-expiratory volume, in accordance with ATS/ERS standards (Miller et al,2005). A minimum of three maneuvers (maximum of eight) will be performed and, in order to be considered reproducible, two curves could not vary by more than 5% or 150mL. The higher value of two reproducible curves will be used for analysis. DH is considered when the IC decreased 10% and/or 150mL or more compared to the basal value (O'Donnell et al, 2001).

Six-minute walk test The 6MWT will be performed according to the guidelines of the American Thoracic Society (2002). Pulse oxygen saturation (SpO2; Oxi-Go, Oximeter Plus, Roslyn Heights, New York, USA) and dyspnea (Borg CR10 scale) will be measured at the beginning and at the end of the test. Predicted values for walking distance will be calculated according to Iwama et al. (2009).

Glittre-ADL test The TGlittre consists of completing a circuit as follows: from a sitting position, the subject stands up and walks along a flat 10-m long course, in the middle of which there is a two-step ladder (each step 17 cm high x 27 cm deep) to be climbed; after completing the 10 m, the subject faces a shelf containing three 1-kg objects positioned on the top shelf (shoulder height) and moves them one by one to the bottom shelf (waist height) and then to the floor; the objects are then returned to the bottom shelf and finally to the top shelf again; the subject walks back, climbing up and down the steps, until reaching the starting point (chair), sits down and immediately begins the next lap. The subjects carry a weighted backpack (2.5 kg for women, 5.0 kg for men) and are instructed to complete five laps on this circuit as quickly as possible. SpO2 and dyspnea index (Borg CR10 scale) will be measured at the beginning of the test, at the end of each lap, and at the end of the test (Skumlien et al, 2006).

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Chronic Obstructive Pulmonary Disease

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

CROSSOVER

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Pursed-lips breathing

All patients performed both tests (six-minute walk test and Glittre ADL test) with pursed-lips breathing.

Group Type EXPERIMENTAL

Pursed-lips breathing

Intervention Type OTHER

Expiration with pursed-lips during functional capacity tests.

No pursed-lips breathing

All patients performed both tests (six-minute walk test and Glittre ADL test) without pursed-lips breathing.

Group Type PLACEBO_COMPARATOR

No pursed-lips breathing

Intervention Type OTHER

To avoid pursed-lips breathing, subjects use a a mouthpiece (2cm diameter X 2cm length) such as the one used in pulmonary functional tests.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Pursed-lips breathing

Expiration with pursed-lips during functional capacity tests.

Intervention Type OTHER

No pursed-lips breathing

To avoid pursed-lips breathing, subjects use a a mouthpiece (2cm diameter X 2cm length) such as the one used in pulmonary functional tests.

Intervention Type OTHER

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* COPD GOLD stages 2, 3, and 4 of severity of airflow limitation
* history of smoking ≥ 20 pack-years
* clinical stability in the four weeks prior to the study protocol

Exclusion Criteria

* long-term oxygen therapy
* current smoking
* any pulmonary disease other than COPD
* comorbidities that would compromise their ability to perform any of the evaluations in the study
Minimum Eligible Age

40 Years

Maximum Eligible Age

80 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

University of the State of Santa Catarina

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Prof. Dra. Anamaria Fleig Mayer

PhD

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Anamaria F Mayer, PhD

Role: STUDY_DIRECTOR

Universidade do Estado de Santa Catraina

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Núcleo de Aisstência, Ensino e Pesquisa em Reabilitação Pulmonar

Florianópolis, Santa Catarina, Brazil

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Brazil

References

Explore related publications, articles, or registry entries linked to this study.

Miller MR, Hankinson J, Brusasco V, Burgos F, Casaburi R, Coates A, Crapo R, Enright P, van der Grinten CP, Gustafsson P, Jensen R, Johnson DC, MacIntyre N, McKay R, Navajas D, Pedersen OF, Pellegrino R, Viegi G, Wanger J; ATS/ERS Task Force. Standardisation of spirometry. Eur Respir J. 2005 Aug;26(2):319-38. doi: 10.1183/09031936.05.00034805. No abstract available.

Reference Type BACKGROUND
PMID: 16055882 (View on PubMed)

Pereira CA, Sato T, Rodrigues SC. New reference values for forced spirometry in white adults in Brazil. J Bras Pneumol. 2007 Jul-Aug;33(4):397-406. doi: 10.1590/s1806-37132007000400008. English, Portuguese.

Reference Type BACKGROUND
PMID: 17982531 (View on PubMed)

O'Donnell DE, Revill SM, Webb KA. Dynamic hyperinflation and exercise intolerance in chronic obstructive pulmonary disease. Am J Respir Crit Care Med. 2001 Sep 1;164(5):770-7. doi: 10.1164/ajrccm.164.5.2012122.

Reference Type BACKGROUND
PMID: 11549531 (View on PubMed)

Iwama AM, Andrade GN, Shima P, Tanni SE, Godoy I, Dourado VZ. The six-minute walk test and body weight-walk distance product in healthy Brazilian subjects. Braz J Med Biol Res. 2009 Nov;42(11):1080-5. doi: 10.1590/s0100-879x2009005000032. Epub 2009 Oct 2.

Reference Type BACKGROUND
PMID: 19802464 (View on PubMed)

ATS Committee on Proficiency Standards for Clinical Pulmonary Function Laboratories. ATS statement: guidelines for the six-minute walk test. Am J Respir Crit Care Med. 2002 Jul 1;166(1):111-7. doi: 10.1164/ajrccm.166.1.at1102. No abstract available.

Reference Type BACKGROUND
PMID: 12091180 (View on PubMed)

Skumlien S, Hagelund T, Bjortuft O, Ryg MS. A field test of functional status as performance of activities of daily living in COPD patients. Respir Med. 2006 Feb;100(2):316-23. doi: 10.1016/j.rmed.2005.04.022. Epub 2005 Jun 6.

Reference Type BACKGROUND
PMID: 15941658 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

PLB2014

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.