The Laryngeal Mask Airway in Edentulous Geriatric Patients
NCT ID: NCT02197377
Last Updated: 2018-10-19
Study Results
Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.
View full resultsBasic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
60 participants
INTERVENTIONAL
2009-08-31
2010-05-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
We aimed to compare the routinely used laryngeal mask airway in our clinic, the LMA Unique™ with the newly released LMA Supreme™ in edentulous elderly patients for the success in first attempt insertion, ease and time of insertion, and oropharyngeal leak pressure.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Geriatric Patients and Laryngeal Mask Unique
NCT02219282
Laryngeal Mask Supreme and I-Gel in Edentulate Geriatric Patients
NCT03760679
Different Ways of Airway Management in Elective Minor Surgeries in Geriatric Patients
NCT04509960
The Comparison of the Clinical Efficacy Between I-gel and LMA-Supreme, the Two Most Recently Developed Supraglottic Airway Devices, in Elderly Patients
NCT02026791
Comparison in Difficult Airway Scenario Induced in Patients With Laryngeal Mask Airway (LMA)-Classic™, LMA™ - Flexible and LMA - Proseal™
NCT02979171
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Demographic parameters, Mallampati classification and the duration of surgery were recorded. Patients were routinely monitored using ECG, non-invasive blood pressure measurement, pulse oximetry and end-tidal carbon dioxide tension. Depth of anesthesia was monitored with bispectral index (BIS).
Patients were premedicated with midazolam 0.02 mg/kg when venous access was obtained. After 3 min preoxygenation with 100 % oxygen via face mask, anesthesia was induced with fentanyl 1-2 µg/kg and propofol 1-2 mg/kg. When the BIS value was 40-60 the predetermined supraglottic airway device was inserted according to the manufacturer's recommendations. The supraglottic airway devices were deflated fully before insertion. Size 4 LMA was used for those with a weight of 50-70 kg and size 5 LMA for those between 70-100 kg. After insertion, each device was inflated with a hand-held airway manometer (Rusch, Germany) to an intracuff pressure of 60 cm H2O.
An effective airway was defined as the presence of normal thoracoabdominal movement and a square-wave end-tidal carbon dioxide trace. General anesthesia was maintained with sevoflurane, O2 and N2O.
Insertion time was defined as the time from picking up the airway device until connection to the airway circuit. Ease of insertion was graded by the attending anesthesiologist as easy, fair or difficult. If after three attempts insertion was still not successful, the other device was used. If insertion of the other device also failed the patient was endotracheally intubated.
Before the oropharyngeal leak test was carried out, the face of the patient was covered so that the observer was blinded to the airway device. The oropharyngeal leak pressure was determined by transiently stopping ventilation and closing the adjustable pressure-limiting valve with a fresh gas flow of 3 L/min until airway pressure reached a steady state and a voice of leakage was heard. The airway pressure was not allowed to exceed 40 cm H2O.
After successful placement of the LMA Supreme™, a 12 French gauge gastric catheter was inserted via the gastric channel.
Any episode of hypoxemia (SpO2 \< 90%), aspiration or regurgitation,bronchospasm and airway obstruction were documented. After removal of the LMA, it was examined for the presence of visible blood.
In the postanesthesia care unit, a research assistant, who was blinded to the group allocation, interviewed the patients using a predetermined questionnaire to collect data on the postoperative pharyngolaryngeal adverse events. The presence or absence of sore throat, dysphonia and dysphagia was assessed at 1 and 24 h postoperatively.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
SCREENING
DOUBLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Group LMA Unique
The supraglottic airway devices were deflated fully before insertion. Size 4 LMA was used for those with a weight of 50-70 kg and size 5 LMA for those between 70-100 kg. After insertion, each device was inflated with a hand-held airway manometer (Rusch, Germany) to an intracuff pressure of 60 cm H2O.The oropharyngeal leak pressure was determined by transiently stopping ventilation and closing the adjustable pressure-limiting valve with a fresh gas flow of 3 L/min until airway pressure reached a steady state and a voice of leakage was heard. The airway pressure was not allowed to exceed 40 cm H2O.
Group LMA Unique™
The supraglottic airway devices were deflated fully before insertion. After placement an effective airway was defined as the presence of normal thoracoabdominal movement and a square-wave end-tidal carbon dioxide trace.
Group LMA Supreme
The supraglottic airway devices were deflated fully before insertion. Size 4 LMA was used for those with a weight of 50-70 kg and size 5 LMA for those between 70-100 kg. After insertion, each device was inflated with a hand-held airway manometer (Rusch, Germany) to an intracuff pressure of 60 cm H2O.The oropharyngeal leak pressure was determined by transiently stopping ventilation and closing the adjustable pressure-limiting valve with a fresh gas flow of 3 L/min until airway pressure reached a steady state and a voice of leakage was heard. The airway pressure was not allowed to exceed 40 cm H2O.
Group LMA Supreme™
The supraglottic airway devices were deflated fully before insertion.The supraglottic airway devices were deflated fully before insertion. After placement an effective airway was defined as the presence of normal thoracoabdominal movement and a square-wave end-tidal carbon dioxide trace.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Group LMA Unique™
The supraglottic airway devices were deflated fully before insertion. After placement an effective airway was defined as the presence of normal thoracoabdominal movement and a square-wave end-tidal carbon dioxide trace.
Group LMA Supreme™
The supraglottic airway devices were deflated fully before insertion.The supraglottic airway devices were deflated fully before insertion. After placement an effective airway was defined as the presence of normal thoracoabdominal movement and a square-wave end-tidal carbon dioxide trace.
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* 65 years and older
Exclusion Criteria
* Those at risk of gastric content regurgitation/aspiration (previous upper gastro-intestina system surgery, known hiatus hernia, gastroesophageal reflux, history of peptic ulcer, full stomach, pregnancy)
* Possibility of and those with history of difficult intubation (history of impossible intubation, Mallampati classification 3-4, sterno mental distance less than 12 cm, thyromental distance less than 6 cm, head extension less than 90 degrees, mouth opening less than 1.5 cm)
* Those with low pulmonary compliance or high airway resistance (morbid obesity, lung disease)
* Throat pain, dysphagia and dysphonia
65 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Dokuz Eylul University
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Sule Ozbilgin
Anaesthesiology and Reanimation
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
TANGUL KILIÇ, M.D.
Role: PRINCIPAL_INVESTIGATOR
Dokuz Eylül University, School of Medicine, Department of Anesthesiology and Reanimation
SEMİH KUCUKGUCLU, M.D.
Role: STUDY_DIRECTOR
Dokuz Eylül University, School of Medicine, Department of Anesthesiology and Reanimation
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Dokuz Eylül University, School of Medicine, Department of Anesthesiology and Reanimation
Izmi̇r, Narlıdere, Turkey (Türkiye)
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
178/2009
Identifier Type: -
Identifier Source: org_study_id
More Related Trials