Trial Outcomes & Findings for The Laryngeal Mask Airway in Edentulous Geriatric Patients (NCT NCT02197377)

NCT ID: NCT02197377

Last Updated: 2018-10-19

Results Overview

Edentulous elderly patients for the success in first attempt insertion, ease and time of insertion (second).

Recruitment status

COMPLETED

Study phase

NA

Target enrollment

60 participants

Primary outcome timeframe

after anaesthesia induction

Results posted on

2018-10-19

Participant Flow

Participant milestones

Participant milestones
Measure
Group LMA Unique
The supraglottic airway devices were deflated fully before insertion. Size 4 LMA was used for those with a weight of 50-70 kg and size 5 LMA for those between 70-100 kg. After insertion, each device was inflated with a hand-held airway manometer (Rusch, Germany) to an intracuff pressure of 60 cm H2O. Group LMA Supreme™: The supraglottic airway devices were deflated fully before insertion.
Group LMA Supreme
The supraglottic airway devices were deflated fully before insertion. Size 4 LMA was used for those with a weight of 50-70 kg and size 5 LMA for those between 70-100 kg. After insertion, each device was inflated with a hand-held airway manometer (Rusch, Germany) to an intracuff pressure of 60 cm H2O. Group LMA Unique™: The supraglottic airway devices were deflated fully before insertion.
Overall Study
STARTED
30
30
Overall Study
COMPLETED
30
27
Overall Study
NOT COMPLETED
0
3

Reasons for withdrawal

Reasons for withdrawal
Measure
Group LMA Unique
The supraglottic airway devices were deflated fully before insertion. Size 4 LMA was used for those with a weight of 50-70 kg and size 5 LMA for those between 70-100 kg. After insertion, each device was inflated with a hand-held airway manometer (Rusch, Germany) to an intracuff pressure of 60 cm H2O. Group LMA Supreme™: The supraglottic airway devices were deflated fully before insertion.
Group LMA Supreme
The supraglottic airway devices were deflated fully before insertion. Size 4 LMA was used for those with a weight of 50-70 kg and size 5 LMA for those between 70-100 kg. After insertion, each device was inflated with a hand-held airway manometer (Rusch, Germany) to an intracuff pressure of 60 cm H2O. Group LMA Unique™: The supraglottic airway devices were deflated fully before insertion.
Overall Study
Insertion Failure
0
3

Baseline Characteristics

The Laryngeal Mask Airway in Edentulous Geriatric Patients

Baseline characteristics by cohort

Baseline characteristics by cohort
Measure
Group LMA Unique
n=30 Participants
The supraglottic airway devices were deflated fully before insertion. Size 4 LMA was used for those with a weight of 50-70 kg and size 5 LMA for those between 70-100 kg. After insertion, each device was inflated with a hand-held airway manometer (Rusch, Germany) to an intracuff pressure of 60 cm H2O. Group LMA Supreme™: The supraglottic airway devices were deflated fully before insertion.
Group LMA Supreme
n=27 Participants
The supraglottic airway devices were deflated fully before insertion. Size 4 LMA was used for those with a weight of 50-70 kg and size 5 LMA for those between 70-100 kg. After insertion, each device was inflated with a hand-held airway manometer (Rusch, Germany) to an intracuff pressure of 60 cm H2O. Group LMA Unique™: The supraglottic airway devices were deflated fully before insertion.
Total
n=57 Participants
Total of all reporting groups
Age, Categorical
<=18 years
0 Participants
n=93 Participants
0 Participants
n=4 Participants
0 Participants
n=27 Participants
Age, Categorical
Between 18 and 65 years
0 Participants
n=93 Participants
0 Participants
n=4 Participants
0 Participants
n=27 Participants
Age, Categorical
>=65 years
30 Participants
n=93 Participants
27 Participants
n=4 Participants
57 Participants
n=27 Participants
Sex: Female, Male
Female
9 Participants
n=93 Participants
11 Participants
n=4 Participants
20 Participants
n=27 Participants
Sex: Female, Male
Male
21 Participants
n=93 Participants
16 Participants
n=4 Participants
37 Participants
n=27 Participants
Region of Enrollment
Turkey
30 participants
n=93 Participants
27 participants
n=4 Participants
57 participants
n=27 Participants

PRIMARY outcome

Timeframe: after anaesthesia induction

Population: Non parametric data between groups were analyzed with the X2-test, while parametric data were compared with unpaired t-test. P \< 0.05 was considered significant. 3 LMA insertion failed in Group LMA Supreme. Total 27 patients included analysis.

Edentulous elderly patients for the success in first attempt insertion, ease and time of insertion (second).

Outcome measures

Outcome measures
Measure
Group LMA Unique
n=30 Participants
The supraglottic airway devices were deflated fully before insertion. Size 4 LMA was used for those with a weight of 50-70 kg and size 5 LMA for those between 70-100 kg. After insertion, each device was inflated with a hand-held airway manometer (Rusch, Germany) to an intracuff pressure of 60 cm H2O. Group LMA Supreme™: The supraglottic airway devices were deflated fully before insertion.
Group LMA Supreme
n=27 Participants
The supraglottic airway devices were deflated fully before insertion. Size 4 LMA was used for those with a weight of 50-70 kg and size 5 LMA for those between 70-100 kg. After insertion, each device was inflated with a hand-held airway manometer (Rusch, Germany) to an intracuff pressure of 60 cm H2O. Group LMA Unique™: The supraglottic airway devices were deflated fully before insertion.
First Attempt's Success Rate of Insertion
73.3 percentage of participants
86.6 percentage of participants

SECONDARY outcome

Timeframe: before surgery

Population: Non parametric data between groups were analyzed with the X2-test, while parametric data were compared with unpaired t-test. P \< 0.05 was considered significant.

The aim of this study is to compare on the oropharyngeal leak pressure in LMA Unique™ and LMA Supreme™ applications

Outcome measures

Outcome measures
Measure
Group LMA Unique
n=30 Participants
The supraglottic airway devices were deflated fully before insertion. Size 4 LMA was used for those with a weight of 50-70 kg and size 5 LMA for those between 70-100 kg. After insertion, each device was inflated with a hand-held airway manometer (Rusch, Germany) to an intracuff pressure of 60 cm H2O. Group LMA Supreme™: The supraglottic airway devices were deflated fully before insertion.
Group LMA Supreme
n=27 Participants
The supraglottic airway devices were deflated fully before insertion. Size 4 LMA was used for those with a weight of 50-70 kg and size 5 LMA for those between 70-100 kg. After insertion, each device was inflated with a hand-held airway manometer (Rusch, Germany) to an intracuff pressure of 60 cm H2O. Group LMA Unique™: The supraglottic airway devices were deflated fully before insertion.
Oropharyngeal Leak Pressure
17.1 cm H20
Standard Deviation 6.33
20.56 cm H20
Standard Deviation 8.22

Adverse Events

Group LMA Unique

Serious events: 0 serious events
Other events: 0 other events
Deaths: 0 deaths

Group LMA Supreme

Serious events: 0 serious events
Other events: 0 other events
Deaths: 0 deaths

Serious adverse events

Adverse event data not reported

Other adverse events

Adverse event data not reported

Additional Information

Anaesthesiology and Reanimation

DorkuzEU

Phone: 0905055252901

Results disclosure agreements

  • Principal investigator is a sponsor employee
  • Publication restrictions are in place