Use of Real Time Instrumentation (RTI) in Total Shoulder Arthroplasty
NCT ID: NCT01905241
Last Updated: 2021-06-18
Study Results
Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.
View full resultsBasic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
20 participants
INTERVENTIONAL
2013-07-31
2013-12-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Continuing the investigator's work, the investigators propose a clinical case series to evaluate a new surgical instrumentation technique that combines the features of PSI with the IRI technology that investigators have termed Real Time Instrumentation (RTI). Investigators will measure implant placement with RSA and 3D CT imaging. Investigators will measure pre-operative bone quality using quantitative CT to measure trabecular bone volume and correlate these findings with bone samples removed from the glenoid and measured by microCT and mechanical testing of the bone samples. These bone samples will be obtained as part of the routine preparation of the glenoid bone for implant placement. This bone tissue is normally removed and discarded as part of the standard of care for preparation of the bone for placement of the glenoid. Investigators have performed all of the work required to define both the safety of all components of the proposed study in the completed PSI study and the ongoing IRI study. Since application to the IRB for study of the IRI technology Custom Orthopaedic Solutions has received in April 2013 FDA approval for this technology.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Comparison of Glenoid Component Position Using Intelligent Reusable Instrument (IRI) vs Standard Surgical Instruments
NCT01801241
Short-Term Outcomes of Total Shoulder Arthroplasty Using the Titan Modular Total Shoulder System
NCT03956316
Prediction of Development of Scapular Notching Following Reverse Total Shoulder Arthroplasty
NCT02052466
Anatomic TSA Vs RTSA for Glenohumeral Arthritis
NCT04629391
Glenoid Bone Grafting for RTSA: Clinical & Radiographic Outcomes
NCT03151109
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Patients will have standard of care indications for primary anatomic arthroplasty and be able to get a preoperative shoulder CT scan at the Cleveland Clinic or at an outside facility so long as the study includes the entire scapula and has 1 mm or thinner sections. These parameters are required for accurate preoperative planning as well as comparison with the post operative CT scans. Standard of care pre- and post-operative x-rays (AP and axillary views) will also be obtained and can be performed at the Cleveland Clinic or acquired from another health care facility. In all patients the standard x-rays and CT images provided by the radiology department will be available to the surgeon before and during the surgery.
Using the Smartbone surrogate model, the surgeon visually compares the exposed glenoid surface to the Smartbone model to ensure that the two match for size and shape. Any adjustments to the surgical site may be done by the surgeon to optimize the match between the model and the exposed glenoid surface. Prior to molding the bone cement, bone wax is wiped onto the model to ensure proper release of the cement mold. The surgeon will then mold bone cement around the pin in the Smartbone, capturing the trajectory of the pin and the unique contours of the glenoid rim. A small pin sleeve is inserted over the pin to be embedded within the cement model. Once the bone cement has cured, it is removed from the model and placed onto the patients glenoid surface. The bone morphology captured in the mold aligns the mold to the patient's anatomy. When surgeon feels that the model has good fit of the glenoid surface, he may continue with pin placement. After placement of the guide pin, the RTI mold is removed and the remainder of the procedure is completed using the implant manufacturer's equipment and standard surgical protocols. Any adjustments in guide pin position can be performed by the surgeon based upon surgical judgment. The surgeon can make any change needed and use any means or instrument that would otherwise be used for standard of care surgery to place the guide pin in any position that the surgeon believed to be best for the patient. If the pin is changed without the use of the RTI then the patient will be excluded from this study and the reasons for failure of the RTI technology to provide accurate pin placement based upon the surgeons sole determination of accuracy will be recorded and later analyzed as a failure to treat. These patients will not receive postoperative CT Scans as investigators would not be able to use the data.
A hollow core drill bit will be used to prepare the bone in a standard manner to obtain bone cores for study. Prior to implanting the glenoid component, three 1 mm tantalum beads will be inserted into the backside pegs of the component. Investigators have developed methods to place the beads in a manner that has been used by other investigators and validated in the investigators' own experience in 22 cases enrolled in the ongoing IRI clinical study. The desired implant will be placed into a holding device and using a drill guide, a 0.9 mm hole measuring 2 mm deep will be placed in each of the three peripheral pegs of the implant. A 1 mm tantalum bead (RSA biomedical, Umsa Sweden) supplied by the company will then be press fit into the component hole. The implant will then be placed in the glenoid, aligned with the previously drilled peg holes. As standard of care, these peg holes are cemented, thus locking the beads within the implant.
Using manufacturer (RSA biomedical, Umsa Sweden) provided beads and injector gun, four to five 1 mm tantalum beads will be placed in the coracoid, acromion and glenoid. Exact placement of these beads is at the discretion of the surgeon. Patient anatomy and operative exposure will guide the surgeon to the best places to inject the beads; however the surgeon will not be confined to a specific amount of beads in a specific location. The beads just need to be spread out amongst the coracoid, acromion, and glenoid to establish reference points for the RSA imaging. Prior studies looking at shoulder joint kinematics and implant position have used this methodology of bead placement with successful study related outcomes. Investigators have successfully placed bone beads in 22 patients currently treated in the ongoing IRI clinical study without any difficulty or adverse events during or after surgery.
Postoperatively, all patients will receive a CT with Metal Artifact Reduction (MAR)and RSA (if chosen) within 3 weeks of surgery. This will be a CT Scan performed with the patient's arm by the side in a supine position using metal artifact reduction techniques. In addition patients will receive a second CT scan and RSA imaging, provided they originally got RSA, performed 1 year (± 1 month) from surgery. The second CT scan will be performed with MAR techniques and with the patient in the lateral decubitus position with their arm in the overhead position, again using metal artifact reduction techniques. The second set of images, produced with a different body and arm position, also decreases metal artifact than those obtained with the arm placed by the side. This position cannot be comfortably obtained until 3- 6 months after surgery and require healing of the tissues and rehabilitation of the shoulder. Investigators have shown that in a small number of patients the glenoid component can shift in position within the first 3-6 months after surgery making the first CT Scan more accurate for implant position. The images obtained from the postoperative CT scans are placed back into the surgical software and the 3D reconstruction of the postoperative scapula with the implants is compared to the preoperative plan. Using measurement tools within the software, developed at the Cleveland Clinic, investigators will compare the position of the actual glenoid component placed in the patient with the desired position specified by the plan. The use and validation of these imaging methods to precisely measure implant position has been performed at the Cleveland Clinic in a prior IRB approved clinical trial (IRB 10-582).
Preoperatively, the high resolution quantitative CT will measure volumetric bone mineral density and the trabecular network of the glenoid. When available, this will be applied to the preoperative CT for those patients at Cleveland Clinic, Main Campus. Patients who have their preoperative CT completed at non Main Campus facilities will have the standard of care preoperative CT. This will be done at the same visit for the standard of care preoperative CT. Micro CT imaging, which creates a 3D reconstruction of the fine bone structure, in addition to microarchitecture analysis and mechanical testing, will allow assessment of the bone tissue taken from the bone core sample. Between the preoperative imaging and the bone tissue analysis, investigators will have data to properly determine the quality of the bone stock surrounding the implant. Further correlating these data with RSA and 3D CT imaging of implant movement, investigators can fully develop cause and effect of bone quality on glenoid component loosening.
The participating surgeons will be Drs. Joseph Iannotti and Eric Ricchetti. Patients may have surgery at either Cleveland Clinic main campus or at Euclid Hospital. If the procedure is performed at Euclid Hospital, post operative CT scan and RSA (if chosen), will need to be taken at main campus within 3 weeks. The patient will be made aware of this at the time of enrollment and consent.
By comparing the computer-generated preoperative plan to postoperative component placement, investigators will be looking at three outcomes. First, the overall difference in component placement between standard of care instrumentation, intelligent reusable instrument (IRB#12-997), patient specific instruments (IRB #10-582) and real time instrumentation will be compared. Secondly, investigators will compare the placement between the technologies within and between surgeons. Thirdly, investigators will evaluate the difference in implant position between technologies based on severity of pathology. The quality of the bone core sampled will be correlated to the possible loosening of the implants.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Anatomic TSA using RTI
During Anatomic Total Shoulder Arthroplasty (TSA), the surgeon will have use of the SmartBone and the bone cement mold made from the SmartBone (the RTI) to transfer the preoperative plan for glenoid implant positioning to the patient's anatomy.
Anatomic TSA using RTI
Anatomic Total Shoulder Arthroplasty (TSA) will be performed using the SmartBone and Real Time Instrumentation (RTI) to transfer the preoperative plan for glenoid implant positioning to the patient's anatomy.
Anatomic Total Shoulder Arthroplasty
Anatomic Total Shoulder Arthroplasty will be performed by the two surgeons of the study as their Standard of Care. All procedures associated with the surgery will be the same with the exception of the instrumentation used to place the guide pin for placement of the glenoid implant.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Anatomic TSA using RTI
Anatomic Total Shoulder Arthroplasty (TSA) will be performed using the SmartBone and Real Time Instrumentation (RTI) to transfer the preoperative plan for glenoid implant positioning to the patient's anatomy.
Anatomic Total Shoulder Arthroplasty
Anatomic Total Shoulder Arthroplasty will be performed by the two surgeons of the study as their Standard of Care. All procedures associated with the surgery will be the same with the exception of the instrumentation used to place the guide pin for placement of the glenoid implant.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
The Cleveland Clinic
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Joseph Iannotti
Chief of Staff, Executive Administration Florida
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Joseph P Iannotti, MD PhD
Role: PRINCIPAL_INVESTIGATOR
The Cleveland Clinic
Eric T Ricchetti, MD
Role: PRINCIPAL_INVESTIGATOR
The Cleveland Clinic
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Cleveland Clinic Orthopaedic and Rheumatologic Institute
Cleveland, Ohio, United States
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Hendel MD, Bryan JA, Barsoum WK, Rodriguez EJ, Brems JJ, Evans PJ, Iannotti JP. Comparison of patient-specific instruments with standard surgical instruments in determining glenoid component position: a randomized prospective clinical trial. J Bone Joint Surg Am. 2012 Dec 5;94(23):2167-75. doi: 10.2106/JBJS.K.01209.
Provided Documents
Download supplemental materials such as informed consent forms, study protocols, or participant manuals.
Document Type: Study Protocol and Statistical Analysis Plan
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
13-652
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.