Comparison of Glenoid Component Position Using Intelligent Reusable Instrument (IRI) vs Standard Surgical Instruments
NCT ID: NCT01801241
Last Updated: 2021-11-03
Study Results
Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.
View full resultsBasic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
56 participants
INTERVENTIONAL
2013-01-31
2013-12-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Patients will have standard of care indications for primary anatomic arthroplasty and be able to get a pre-operative shoulder CT scan at the Cleveland Clinic or at an outside facility so long as the study includes the entire scapula and has 1mm or thinner sections. These parameters are required for accurate pre operative planning as well as comparison with the post operative CT scans. Standard of care pre- and post-operative x-rays (AP and axillary views) will also be obtained and can be preformed at the Cleveland Clinic or acquired from another health care facility. In all patients the standard x-rays and CT images provided by the radiology department will be available to the surgeon before and during the surgery.
For the experimental group, the cannulated IRIS instrument designed for glenoid pin placement is placed over the guide wire that is contained within the sterile SmartBone and the legs of the instrument are adjusted to record the relationship (location and trajectory) of the guide pin in relation to the patient specific glenoid anatomy. This is done at the time of surgery to properly mimic the desired pin placement. The location of each leg of the IRI is marked on the SmartBone with a surgical pen. The instrument is then removed from the smart bone model. The SmartBone model is visually compared by the surgeon to the exposed bone surface to ensure that the two match for shape and size. Any adjustments to the surgical site may be done by the surgeon to optimize the match between the model and the exposed glenoid surface. The marks placed by the surgeon on the model are then transferred to the patient bone using a surgical marker or bovie. These marks are in a general location as determined by the surgeon and assist in the placement of the IRI. The IRI is placed onto the patient bone surface in the same manner as it was placed on the SmartBone model and a guide pin provided by the manufacturer is placed into the desired position. The surgeon then removes the IRI and compares by visual inspection the location and trajectory of the guide pin in relation to the patients bone surface and that within the SmartBone's model. Any adjustments in guide pin position can be performed by the surgeon based upon surgical judgment. The surgeon can make any change needed and use any means or instrument that would otherwise be used for standard of care surgery to place the guide pin in any position that the surgeon believed to be best for the patient. If the pin is changed without the use of the IRI then the patient will be excluded from this study and the reasons for failure of the IRI technology to provide accurate pin placement based upon the surgeon's sole determination of accuracy will be recorded and later analyzed as a failure to treat. These patients will not receive post operative CT Scans as we would not be able to use the data within any one group as defined by this study. After placement of the guide pin the remainder of the procedure is completed in the same manner for both groups, using the implant manufacturer's equipment.
In the standard instrument group the surgeon will use the pre operative CT Scan at least two weeks prior to surgery to define the glenoid pathology, select the implant of choice and place that implant in the desired position. This information will be available to the surgeon at the time of surgery but the SmartBone models and the IRI will not be available. The surgeon will have the pre operative x-rays and the pre operative CT scan provided by the radiology department for intra - operative use. The surgeon will perform the surgery using any of the instruments provided for guide pin placement. These include a wide variety of free hand and adjustable guides that assist the surgeon for placement of the guide pin for location and trajectory. Which tools are used for each case will be recorded at the time of surgery.
Prior to discharge, the patient will receive a post-operative CT scan. This will be a CT scan performed with the patient's arm by the side in a supine position using metal artifact reduction techniques. In addition patients will receive a second CT scan performed 1 year (± 1 month) from surgery. These scans will be performed with the patient in the lateral decubitus position with their arm in the overhead position again using metal artifact reduction techniques. The second set of images produced with a different body and arm position will generate much less metal artifact than those obtained immediately after surgery. This position can not be safely obtained until 3- 6 months after surgery and requires healing of the tissues and rehabilitation of the shoulder. We have shown that in a small number of patients the glenoid component can shift in position within the first 3-6 months after surgery making the first CT scan more accurate for implant position. The images obtained from the post-operative CT scans are placed back into the surgical software and the 3D reconstruction of the post-operative scapula with the implants is compared to the pre-operative plan. Using measurement tools within the software, developed at the Cleveland Clinic, we will compare the position of the actual glenoid component placed in the patient with the desired position specified by the plan. The use and validation of these imaging methods to precisely measure implant position has been performed at the Cleveland Clinic in a prior IRB approved clinical trial (IRB 10-582).
The participating surgeons will be Dr. Joseph Iannotti and Dr. Eric Ricchetti.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Keywords
Explore important study keywords that can help with search, categorization, and topic discovery.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
TREATMENT
DOUBLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Anatomic TSA using SOC Instrumentation
During Anatomic Total Shoulder Arthroplasty, the surgeon will use the pre operative CT scan at least two weeks prior to surgery to define the glenoid pathology, select the implant of choice and plan the placement of that implant in the desired position. This information will be available to the surgeon at the time of surgery but the SmartBone models and the IRI will not be available. The surgeon will have pre operative x-rays and the pre operative CT scan provided by the radiology department for intra - use. The surgeon will perform the surgery using any of the instruments provided for guide pin placement operative the. These include a wide variety of free hand and adjustable guides that assist the surgeon for placement of the guide pin for location and trajectory.
Anatomic Total Shoulder Arthroplasty
Anatomic Total Shoulder Arthroplasty will be performed by the two surgeons of the study as their Standard of Care. All procedures associated with the surgery will be the same in the two arms, with the exception of the tools used to place the guide pin for placement of the glenoid implant.
Anatomic TSA Using IRI Instrumentation
During Anatomic Total Shoulder Arthroplasty, the surgeon will have use of the SmartBone model of the patient's anatomy and glenoid guide-pin location, and the Intelligent Reuseable Instrument for placement of the glenoid implant.
Anatomic TSA using IRI Instrumentation
Anatomic Total Shoulder Arthroplasty (TSA) will be performed using the SmartBone and Intelligent Reusable Instrument (IRI) to transfer the pre-operative plan for glenoid implant positioning to the patient's anatomy.
Anatomic Total Shoulder Arthroplasty
Anatomic Total Shoulder Arthroplasty will be performed by the two surgeons of the study as their Standard of Care. All procedures associated with the surgery will be the same in the two arms, with the exception of the tools used to place the guide pin for placement of the glenoid implant.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Anatomic TSA using IRI Instrumentation
Anatomic Total Shoulder Arthroplasty (TSA) will be performed using the SmartBone and Intelligent Reusable Instrument (IRI) to transfer the pre-operative plan for glenoid implant positioning to the patient's anatomy.
Anatomic Total Shoulder Arthroplasty
Anatomic Total Shoulder Arthroplasty will be performed by the two surgeons of the study as their Standard of Care. All procedures associated with the surgery will be the same in the two arms, with the exception of the tools used to place the guide pin for placement of the glenoid implant.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
The Cleveland Clinic
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Joseph Iannotti
Cheif of Staff, Executive Administration Florida
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Joseph P Iannotti, MD, PhD
Role: PRINCIPAL_INVESTIGATOR
The Cleveland Clinic
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Cleveland Clinic Orthopaedic and Rheumatologic Institute
Cleveland, Ohio, United States
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Hendel MD, Bryan JA, Barsoum WK, Rodriguez EJ, Brems JJ, Evans PJ, Iannotti JP. Comparison of patient-specific instruments with standard surgical instruments in determining glenoid component position: a randomized prospective clinical trial. J Bone Joint Surg Am. 2012 Dec 5;94(23):2167-75. doi: 10.2106/JBJS.K.01209.
Iannotti JP, Weiner S, Rodriguez E, Subhas N, Patterson TE, Jun BJ, Ricchetti ET. Three-dimensional imaging and templating improve glenoid implant positioning. J Bone Joint Surg Am. 2015 Apr 15;97(8):651-8. doi: 10.2106/JBJS.N.00493.
Provided Documents
Download supplemental materials such as informed consent forms, study protocols, or participant manuals.
Document Type: Study Protocol and Statistical Analysis Plan
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
IPP-12-245
Identifier Type: -
Identifier Source: org_study_id