Long-terms Effects of Simulation-based Ultrasound Training: A Randomized Trial
NCT ID: NCT01895868
Last Updated: 2014-04-07
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
26 participants
INTERVENTIONAL
2013-07-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Evaluation of a New Training Model for Ultrasound Guided Regional Anesthesia - A Feasibility Study
NCT02370472
Optimizing Ultrasound-induced Anti-inflammation in Human Subjects
NCT05685108
Low-intensity Focused Ultrasound and Autonomic Response
NCT05834829
Artificial Intelligence Empowered Anesthesia Ultrasound Guided Regional Anesthesia Training
NCT06546904
Improvement of Needle Visibility in Ultrasound Guided Regional Anaesthesia
NCT01583010
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
In a group of ultrasound novices, what are the implications of simulation-based training compared to clinical training alone on the technical quality of scans performed after two months of training?
Methods
Study design This study is reported according to the CONSORT statement (www.consort-statement.org). A randomized observer-blind study to compare VR ultrasound training with traditional supervised practice on subsequent patient scans (see Figure 1 for flowchart of study design). Ethical approval was obtained from the Regional Ethical Committee of the Capital Region, Denmark. The Danish Data Protection Agency approved the storing of patient relevant information. This randomized trial is reported to clinicaltrials.gov prior to inclusion of participants.
Setting This study is carried out at the Departments of Gynecology at the Juliane Marie Centre, Copenhagen University Hospital, Denmark, Næstved Hospital, and Hillerød Hospital.
Participants Participants are all new OB/GYN residents at three different hospitals in Eastern Denmark. Inclusion criteria are 1) proficiency in written and oral Danish, 2) informed written consent. The exclusion criteria are 1) prior employment at an OB/GYN department in a clinical position, 2) any formal ultrasound training with or without hands-on practice and (3) prior experience with virtual reality simulation.
Randomization A research fellow at The Center for Clinical Education, Rigshospitalet, independently performs randomisation of participants by computer to either intervention group (simulation training) or control group (clinical training only). The allocation of participants is concealed to the primary investigator during the enrolment of participants. Once informed consent has been signed and a participant number has been provided, the allocation sequence is retrieved per telephone.
Intervention Participants in the intervention group receive simulation training using two types of ultrasound simulators (see Figure 2 for flowchart of the simulation programme). Participants are introduced to a high-fidelity Virtual-Reality (VR) simulator (Scantrainer, Medaphor). The VR simulator provides images obtained from real patients and haptic feedback from the ultrasound probe. Participants train on this type of simulator until a predefined proficiency-level has been attained. The selection of modules is based on a previous validation study and only modules and items that discriminate between novice and expert performances are included in the training programme (Madsen et al. 2013). All participants are provided feedback after completing each module. When all modules are passed on the VR simulator, the participants receive proficiency-based training training on the low-fidelity simulator (BluePhantom) to allow participants to review the functions, they just trained, using real ultrasound equipment. The simulator performances are assessed using the Objective Structured Examination of Ultrasound Skills (OSAUS) and feedback is provided using this framework after each trial. Proficiency is set according pass/fail-scores established in a previous study (Tolsgaard et al. 2013).
Clinical training Participants in both groups receive traditional clinical training. This includes supervised practice in terms of apprenticeship learning followed by supervision during independent practice. The new residents do not usually go on calls for the first one to two weeks. Local department rules dictates which types of examinations that always requires a second examination by a supervising clinicians (e.g. fetal demise or pregnancy of unknown location).
Main outcome measure The main outcome measure is the technical proficiency after two months of practice. Two scans from the emergency department are recorded and subsequently assessed by a blinded clinician, who also had access to the ultrasound descriptions that corresponded to each scan. The assessments were performed using the Objective Structured Assessment of Ultrasound Skills (Tolsgaard et al. 2013), which has been validated in a construct validity study including 30 clinicians with different levels of experience prior to this trial.
Sample size calculation Sample size calculations are based on previous studies on clinical performances of ultrasound novices with the performance of medical students, who completed a simulation-based training programme (Tolsgaard et al. 2013). The average difference in OSAUS scores between these groups was 0.85 (2.65-1.8 (mean SD 0.4). It was anticipated that these differences would be diluted according to literature from other areas of simulation-based technical skills training (Smith et al. 2010), where simulation effects persisted after 3 months of training but the differences between groups was diminished to 55% of the initial effects. Assuming a 55% dilution, an alpha-level of 0.05 and a power of 0.80, the total number of participants needed was 26.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
SINGLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Simulation-based training
Participants in the intervention group receive simulation training using two types of ultrasound simulators: The Scantrainer (Medaphor) and the BluePhantom (CAE). All participants are training to pre-established proficiency-criteria.
Simulation-based ultrasound training
Control
Clinical training alone.
No interventions assigned to this group
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Simulation-based ultrasound training
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Rigshospitalet, Denmark
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Martin G. Tolsgaard
MD PhD
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Dept. Gynecology, Rigshospitalet.
Copenhagen, Copenhagen, Denmark
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Tolsgaard MG, Ringsted C, Dreisler E, Norgaard LN, Petersen JH, Madsen ME, Freiesleben NL, Sorensen JL, Tabor A. Sustained effect of simulation-based ultrasound training on clinical performance: a randomized trial. Ultrasound Obstet Gynecol. 2015 Sep;46(3):312-8. doi: 10.1002/uog.14780. Epub 2015 Aug 6.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
H-3-2012-154
Identifier Type: OTHER
Identifier Source: secondary_id
H-3-2012-154
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.