Blinding and Adverse Effects of Ultrasonic Vagus Nerve Stimulation (U-VNS) in Tinnitus
NCT ID: NCT07291648
Last Updated: 2025-12-18
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
RECRUITING
NA
20 participants
INTERVENTIONAL
2025-09-01
2025-12-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Two types of vagus nerve stimulation (VNS) have been trialled: 1) invasive VNS, using a surgically implanted vagus nerve stimulator and 2) non-invasive VNS, using electrical stimulation devices that are placed on the skin, near a section of the vagus nerve. Past studies of these techniques show that VNS may be a promising future treatment for tinnitus. However, there is not enough data available to draw a firm conclusion on whether VNS is effective at reducing tinnitus or not. Furthermore, all previous studies of VNS for tinnitus have used electrical stimulation of the vagus nerve. Stimulating the vagus nerve, whether through an implanted device or a device on the skin, comes with serious technical challenges. Most importantly, electric currents follow the path of least resistance. When running through biological tissues, such as skin, cartilage or bone, it is difficult to aim for the part of the body that needs to be stimulated. This means it isn't always easy to tell whether the vagus nerve is indeed being stimulated and how much of the current is actually reaching the vagus nerve.
This problem can be overcome by ultrasound stimulation. Ultrasound stimulation employs high frequency sound waves to stimulate tissue. These soundwaves travel through the human body much more predictably than electric currents. As such, ultrasound stimulation of the vagus nerve may be more effective than electrical stimulation. The ZenBud device is designed to apply ultrasound stimulation to part of the vagus nerve that runs through the ear. Ultrasound stimulation allows for more targeted stimulation, increasing the chance of the stimulation reaching the vagus nerve. The ZenBud device is safe for use in healthy adults and received CE marking based on CE assessments conducted at the University of Nottingham).
A study found that healthy volunteers can't tell whether they're receiving real U-VNS or sham. It also found that adverse effects are mild, short-lasting and are most commonly feelings of pressure, pain, tingling or warming up of the skin where the device sits on the ear. The next step is to see whether these findings are the same in people with tinnitus. This study aims to 1) investigate the effectiveness of blinding of U-VNS vs sham, 2) evaluate the intensity, onset and duration of any adverse effects of U-VNS in people with tinnitus, and 3) assess the acceptability of U-VNS in people with tinnitus.
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
CROSSOVER
OTHER
SINGLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Device: Ultrasound Vagus Nerve Stimulation (U-VNS)
Ultrasound stimulation of the auricular branch of the vagus nerve using the ZenBud device manufactured by NeurGear (Rochester, New York, USA), a CE-compliant over-the-ear headset. It delivers low-intensity focused ultrasound to the auricular branch of the vagus nerve through several layers of skin (centre frequency 5.3 MHz, pulse repetition rate 41 hertz, 50% duty cycle, average intensity of 1.03 MPa).
Device: Ultrasound Vagus Nerve Stimulation (U-VNS)
Ultrasound stimulation of the auricular branch of the vagus nerve using the ZenBud device manufactured by NeurGear (Rochester, New York, USA), a CE-compliant over-the-ear headset. It delivers low-intensity focused ultrasound to the auricular branch of the vagus nerve through several layers of skin (centre frequency 5.3 MHz, pulse repetition rate 41 hertz, 50% duty cycle, average intensity of 1.03 MPa).
Sham Comparator: Sham
Sham device, also produced by NeurGear, which is identical in appearance to the true ZenBud device, emits the same sound and warms up slightly where the transducer sits on the skin.
Device: Sham U-VNS
Sham device, also produced by NeurGear, which is identical in appearance to the true ZenBud device, emits the same sound and warms up slightly where the transducer sits on the skin.
Device: Ultrasound Vagus Nerve Stimulation (U-VNS)
Ultrasound stimulation of the auricular branch of the vagus nerve using the ZenBud device manufactured by NeurGear (Rochester, New York, USA), a CE-compliant over-the-ear headset. It delivers low-intensity focused ultrasound to the auricular branch of the vagus nerve through several layers of skin (centre frequency 5.3 MHz, pulse repetition rate 41 hertz, 50% duty cycle, average intensity of 1.03 MPa).
Sham Comparator: Sham
Sham device, also produced by NeurGear, which is identical in appearance to the true ZenBud device, emits the same sound and warms up slightly where the transducer sits on the skin.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Device: Ultrasound Vagus Nerve Stimulation (U-VNS)
Ultrasound stimulation of the auricular branch of the vagus nerve using the ZenBud device manufactured by NeurGear (Rochester, New York, USA), a CE-compliant over-the-ear headset. It delivers low-intensity focused ultrasound to the auricular branch of the vagus nerve through several layers of skin (centre frequency 5.3 MHz, pulse repetition rate 41 hertz, 50% duty cycle, average intensity of 1.03 MPa).
Sham Comparator: Sham
Sham device, also produced by NeurGear, which is identical in appearance to the true ZenBud device, emits the same sound and warms up slightly where the transducer sits on the skin.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Has experienced constant idiopathic tinnitus for at least 6 months
* Participant is willing and able to give informed consent for participation in the study
* Not currently taking any medication (except the contraceptive pill)
* Able and willing to remove any piercings in the left ear
Exclusion Criteria
* Current or past diagnosis of cardiac arrhythmia
* No tinnitus
* Has tinnitus, but it is objective, intermittent or onset is less than 6 months ago
* Use of medication or recreational drugs that affect the nervous system in the past 3 months
* Currently pregnant
* Allergy to aquasonic gel or any of its components (propylene glycol, glycerin, isothiazolinones)
* Having taken part in a research study in the last 3 months involving invasive procedures or an inconvenience allowance (this must remain for ALL UoN FMHS UREC approved studies)
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
University of Nottingham
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Magdalena Sereda
Assistant Professor
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Bas Labree, PhD
Role: PRINCIPAL_INVESTIGATOR
NIHR Nottingham BRC / University of Nottingham
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
University of Nottingham
Nottingham, , United Kingdom
Countries
Review the countries where the study has at least one active or historical site.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Facility Contacts
Find local site contact details for specific facilities participating in the trial.
Bas Labree, PhD
Role: primary
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
FMHS 183-0625
Identifier Type: -
Identifier Source: org_study_id