A Comparison of Air Insufflation, Water Immersion and Water Exchange Colonoscopy in CRC Screening

NCT ID: NCT01780818

Last Updated: 2014-01-15

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Clinical Phase

NA

Total Enrollment

288 participants

Study Classification

INTERVENTIONAL

Study Start Date

2013-03-31

Study Completion Date

2013-11-30

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Water-aided method for colonoscopy can be broadly subdivided into two major categories. Water Immersion (WI), characterized by suction removal of the infused water predominantly during the withdrawal phase of colonoscopy, and Water Exchange (WE), characterized by suction removal of infused water predominantly during the insertion phase of colonoscopy. Several studies showed that WE significantly reduces pain compared to WI and colonoscopy with traditional air insufflation (AI), increases the number of unsedated procedures and adenoma detection rate (ADR), in particular proximal ADR. This randomized controlled trial will be a direct comparison of Air Insufflation, Water Immersion and Water Exchange to test the hypothesis that WAC (particularly WE) would significantly decrease pain score during colonoscopy in average-risk screening patients. Several other secondary outcomes will also be analyzed.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Introduction

Water-aided methods for colonoscopy can be broadly subdivided into two major categories. Water Immersion (WI) is characterized by suction removal of the infused water predominantly during the withdrawal phase of colonoscopy and Water Exchange (WE) is characterized by suction removal of infused water predominantly during the insertion phase of colonoscopy. Several studies showed that WE significantly reduces pain compared to WI and colonoscopy with traditional air insufflation (AI), increases the number of unsedated procedures and adenoma detection rate (ADR), in particular proximal ADR. This randomized controlled trial will be a direct comparison of Air Insufflation, Water Immersion and Water Exchange to test the hypothesis that WAC (particularly WE) would significantly decrease pain score during colonoscopy in average-risk screening patients. Several other secondary outcomes will also be analyzed.

Method

Examinations will be allocated to Water Exchange, Water Immersion or Air Insufflation during the insertion phase of colonoscopy based on a computer generated random list. Procedures will be started by 6 board-certified endoscopists, three with experience in 8,000-10,000 and three with experience in 2,000-5,000 colonoscopies with AI, 285 with WI and 890 with WE overall. High-resolution wide-angle variable-stiffness adult video colonoscopes (Olympus HD 180 series; Olympus Corp, Hamburg, Germany) will be used. Need to change to a smaller caliber colonoscope will be considered ITT failure.

Patients will have a low volume split dose bowel preparation with 2L of polyethylene glycol (PEG) solution or Sodium Picosulfate. Investigators will be blinded to the colon preparation used. Before starting the procedure, a questionnaire recording demographic data, previous abdominal surgery, co-morbidities and current medications will be administered by the endoscopists. The patients, but not endoscopists and assisting nurses, will be blinded to the method used. At discharge the patient will be asked to guess which method has been used. If no more than half of the responses are correct, patients' blinding will be considered adequate.

Colonoscopy will begin with the patients in the left lateral position, without premedication.

The withdrawal phase will be identical in all arms of the study using air insufflation to obtain adequate distension of the colonic lumen for mucosal inspection, biopsy and/or polypectomy.

Patients randomized to the water-aided colonoscopy group, during the insertion phase after reaching the rectosigmoid junction, will have the colon irrigated with water at 37°C maintained with a water bath. Infusions will be performed using flushing pumps (Olympus OFP2, Olympus, Hamburg, Germany or Velocity irrigation pump, US Endoscopy, OH, USA). There will be no restriction of the overall volume of water that can be infused to get adequate lumen distention and reach the cecum. With the patient in the left lateral position water infused into the colon at the rectal sigmoid junction flows into the descending colon. The weight of the water in the left side of the colon straightens the sigmoid segment increasing the ease of insertion and reducing the risk of loop formation. The air pump will be turned off to avoid inadvertent insufflation.

Water Immersion will involve the infusion of water during the insertion phase of colonoscopy mainly to open the colonic lumen and progress to the cecum immersed in the water environment thus created, without attempting to clear the colon contents. Use of water as an adjunct to air insufflation to facilitate insertion and removal of infused water predominantly during withdrawal are characteristic features of WI. This traditional adjunct facilitates passage through the sigmoid colon with severe diverticulosis, speeds arrival to the splenic flexure, decreases colonic spasm, minimizes pain, and even enhances cecal intubation in previously incomplete colonoscopies. Residual air in the colon will not be removed. The infused water and residual feces will be suctioned back only during withdrawal. Air insufflation will be allowed if the lumen cannot be seen and the endoscopists judges unsafe to advance the colonoscope. It will last no more than 10 seconds and will be recorded in the patient data sheet. If more than 3 episodes of air insufflation will be recorded the procedure will be considered ITT failure.

Water Exchange will involve complete exclusion of air insufflation, removal of residual colonic air and feces and of infused water predominantly during insertion to assist identification of the lumen. WE minimizes loop formation and decreases discomfort. By providing salvage cleansing during insertion, WE allows the colonoscopist to devote a greater proportion of the withdrawal to inspection. WE will involve the infusion of a sufficient amount of water to open the lumen of the colon to allow passage of the instrument, thus rendering the colonic lumen a slit to progress with the colonoscope. If the lumen does not open, the colonoscope will be slightly retracted and the infusion started again. Part of the infused water will be constantly suctioned back exchanging clean for dirty or hazy water. Suction of infused water will also be applied when colonoscope insertion proceeds smoothly. Air pockets, when encountered, will be always aspirated to collapse the lumen: the absence of air space forces the colonoscopist to use water to clear residual feces and to find the way through the colon. Removal of the air also shortens the colon and takes out all the sharp turns at the flexures and redundant segments, reducing the risk of loop formation: water instillation does not elongate the colon as much as air insufflation does. In a collapsed, airless colon turbulences created at the tip of the instrument facilitate the removal by suction of residual feces adherent to the mucosa. This provides salvage cleansing during the insertion phase. After cecal intubation as much residual water as possible will be aspirated before beginning the withdrawal phase. During withdrawal scarce amounts of water are left to aspirate, and residual water and feces will be suctioned.

In the AI group, colonoscopy will be performed in the standard fashion, allowing for washing as needed. In all groups abdominal compression and position change were applied as needed.

Cecal intubation will be defined as passage of the tip of the colonoscope to a point proximal to the ileocecal valve with adequate visualization of the cecum and appendix orifice. A stopwatch will be used to time the procedures. Cecal intubation time will be defined as the time for passage of the colonoscope from the rectum to the cecum. The withdrawal phase will last at least 6 minutes. Polyp resection will be done during withdrawal in all groups. Time for polypectomy or biopsy will add to the total colonoscopy time. Pathology reports of all polyps will be reviewed and recorded to evaluate adenoma detection rate (ADR, defined as the proportion of subjects with at least one adenoma of any size), the location, the total number of adenomas resected per subject (ARR), and the percentage of subjects with advanced adenomas. The amount of water infused during insertion and withdrawal, the number of position changes and any adverse outcome will be recorded. Cardiopulmonary function will be monitored. Significant oxygen desaturation (\<85% for \>15 seconds) will be recorded. Vagal reaction will be defined as heart rate \<60 beats per minute accompanied by excessive sweating, nausea and/or vomiting.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Pain Colorectal Adenomas Colorectal Cancer

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

TREATMENT

Blinding Strategy

SINGLE

Participants

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Air insufflation method.

Colonoscopy will be performed in the standard fashion, with the minimal air insufflation required to aid insertion and allowing for washing as needed. Considered to be standard procedure.

Group Type ACTIVE_COMPARATOR

Air Insufflation method.

Intervention Type OTHER

Colonoscopy will be performed in the standard fashion, with the minimal air insufflation required to aid insertion and allowing for washing as needed. Considered to be standard procedure.

Water Immersion method.

Air will not be insufflated until the cecum is reached. It will be allowed only 3 times and no more than 10 seconds each time (ITT failure if \>3) if the lumen cannot be seen. Infusion of water during the insertion phase of colonoscopy mainly to open the colonic lumen and progress to the cecum immersed in the water environment thus created, without attempting to clear the colon contents. Residual air in the colon will not be removed. Infused water and residual feces will be suctioned back predominantly during withdrawal.

Group Type EXPERIMENTAL

Water Immersion method.

Intervention Type OTHER

Air will not be insufflated until the cecum is reached. It will be allowed only 3 times and no more than 10 seconds each time (ITT failure if \>3) if the lumen cannot be seen. Infusion of water during the insertion phase of colonoscopy mainly to open the colonic lumen and progress to the cecum immersed in the water environment thus created, without attempting to clear the colon contents. Residual air in the colon will not be removed. Infused water and residual feces will be suctioned back predominantly during withdrawal.

Water Exchange method.

Air will not be insufflated until the cecum is reached. Infusion of a sufficient amount of water to render the lumen of the colon a slit to progress with the colonoscope. Part of the infused water will be constantly suctioned back exchanging clean for dirty or hazy water. Suction of water will also be applied when colonoscope insertion proceeds smoothly. Air pockets will be always aspirated to collapse the lumen. After cecal intubation as much residual water as possible will be aspirated before beginning the withdrawal phase. During withdrawal residual water and feces will be suctioned.

Group Type EXPERIMENTAL

Water Exchange method.

Intervention Type OTHER

Air will not be insufflated until the cecum is reached. Infusion of a sufficient amount of water to render the lumen of the colon a slit to progress with the colonoscope. Part of the infused water will be constantly suctioned back exchanging clean for dirty or hazy water. Suction of water will also be applied when colonoscope insertion proceeds smoothly. Air pockets will be always aspirated to collapse the lumen. After cecal intubation as much residual water as possible will be aspirated before beginning the withdrawal phase. During withdrawal residual water and feces will be suctioned.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Air Insufflation method.

Colonoscopy will be performed in the standard fashion, with the minimal air insufflation required to aid insertion and allowing for washing as needed. Considered to be standard procedure.

Intervention Type OTHER

Water Immersion method.

Air will not be insufflated until the cecum is reached. It will be allowed only 3 times and no more than 10 seconds each time (ITT failure if \>3) if the lumen cannot be seen. Infusion of water during the insertion phase of colonoscopy mainly to open the colonic lumen and progress to the cecum immersed in the water environment thus created, without attempting to clear the colon contents. Residual air in the colon will not be removed. Infused water and residual feces will be suctioned back predominantly during withdrawal.

Intervention Type OTHER

Water Exchange method.

Air will not be insufflated until the cecum is reached. Infusion of a sufficient amount of water to render the lumen of the colon a slit to progress with the colonoscope. Part of the infused water will be constantly suctioned back exchanging clean for dirty or hazy water. Suction of water will also be applied when colonoscope insertion proceeds smoothly. Air pockets will be always aspirated to collapse the lumen. After cecal intubation as much residual water as possible will be aspirated before beginning the withdrawal phase. During withdrawal residual water and feces will be suctioned.

Intervention Type OTHER

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Consecutive 50 to 70 year-old first time average-risk screening patients agreeing to start procedure without premedication.

Exclusion Criteria

* patient unwillingness to start the procedure without sedation/analgesia
* previous colorectal surgery
* patient refusal or inability to provide informed consent
* inadequate bowel preparation (patients unable to swallow at least ¾ of cleansing preparation, or that did have late and insufficient evacuations, or that reported the presence of residual stools in the last evacuations).
Minimum Eligible Age

50 Years

Maximum Eligible Age

70 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Presidio Ospedaliero Santa Barbara

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Sergio Cadoni, M.D.

Responsabile Servizio Endoscopia Digestiva

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Sergio Cadoni, MD

Role: PRINCIPAL_INVESTIGATOR

S. Barbara Hospital, Iglesias (CA), Italy

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Sepulveda Ambulatory Care Center, VA Greater Los Angeles Healthcare System

Los Angeles, California, United States

Site Status

S. Barbara Hospital

Iglesias, Cagliari, Italy

Site Status

N. S. di Bonaria Hospital

San Gavino Monreale, VS, Italy

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States Italy

References

Explore related publications, articles, or registry entries linked to this study.

Leung FW, Amato A, Ell C, Friedland S, Harker JO, Hsieh YH, Leung JW, Mann SK, Paggi S, Pohl J, Radaelli F, Ramirez FC, Siao-Salera R, Terruzzi V. Water-aided colonoscopy: a systematic review. Gastrointest Endosc. 2012 Sep;76(3):657-66. doi: 10.1016/j.gie.2012.04.467.

Reference Type BACKGROUND
PMID: 22898423 (View on PubMed)

Brocchi E, Pezzilli R, Tomassetti P, Campana D, Morselli-Labate AM, Corinaldesi R. Warm water or oil-assisted colonoscopy: toward simpler examinations? Am J Gastroenterol. 2008 Mar;103(3):581-7. doi: 10.1111/j.1572-0241.2007.01693.x. Epub 2007 Dec 12.

Reference Type BACKGROUND
PMID: 18076732 (View on PubMed)

Rabenstein T, Radaelli F, Zolk O. Warm water infusion colonoscopy: a review and meta-analysis. Endoscopy. 2012 Oct;44(10):940-51. doi: 10.1055/s-0032-1310157. Epub 2012 Sep 17.

Reference Type BACKGROUND
PMID: 22987214 (View on PubMed)

Leung CW, Kaltenbach T, Soetikno R, Wu KK, Leung FW, Friedland S. Water immersion versus standard colonoscopy insertion technique: randomized trial shows promise for minimal sedation. Endoscopy. 2010 Jul;42(7):557-63. doi: 10.1055/s-0029-1244231. Epub 2010 Jun 30.

Reference Type BACKGROUND
PMID: 20593332 (View on PubMed)

Leung FW. Water exchange may be superior to water immersion for colonoscopy. Clin Gastroenterol Hepatol. 2011 Dec;9(12):1012-4. doi: 10.1016/j.cgh.2011.09.007. Epub 2011 Sep 22. No abstract available.

Reference Type BACKGROUND
PMID: 21946120 (View on PubMed)

Leung F, Harker J, Leung J, Siao-Salera R, Mann S, Ramirez F, Friedland S, Amato A, Radaelli F, Paggi S, Terruzzi V, Hsieh Y. Removal of infused water predominantly during insertion (water exchange) is consistently associated with a greater reduction of pain score - review of randomized controlled trials (RCTs) of water method colonoscopy. J Interv Gastroenterol. 2011 Jul;1(3):114-120. doi: 10.4161/jig.1.3.18510. Epub 2011 Jul 1.

Reference Type BACKGROUND
PMID: 22163081 (View on PubMed)

Radaelli F, Paggi S, Amato A, Terruzzi V. Warm water infusion versus air insufflation for unsedated colonoscopy: a randomized, controlled trial. Gastrointest Endosc. 2010 Oct;72(4):701-9. doi: 10.1016/j.gie.2010.06.025.

Reference Type BACKGROUND
PMID: 20883846 (View on PubMed)

Pohl J, Messer I, Behrens A, Kaiser G, Mayer G, Ell C. Water infusion for cecal intubation increases patient tolerance, but does not improve intubation of unsedated colonoscopies. Clin Gastroenterol Hepatol. 2011 Dec;9(12):1039-43.e1. doi: 10.1016/j.cgh.2011.06.031. Epub 2011 Jul 13.

Reference Type BACKGROUND
PMID: 21749850 (View on PubMed)

Cadoni S, Sanna S, Gallittu P, Argiolas M, Fanari V, Porcedda ML, Erriu M, Leung FW. A randomized, controlled trial comparing real-time insertion pain during colonoscopy confirmed water exchange to be superior to water immersion in enhancing patient comfort. Gastrointest Endosc. 2015 Mar;81(3):557-66. doi: 10.1016/j.gie.2014.07.029. Epub 2014 Sep 26.

Reference Type DERIVED
PMID: 25262100 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

ASL07_WW-2012

Identifier Type: OTHER

Identifier Source: secondary_id

PG.2012.27110

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.