Evaluation of the Vascutek Hybrid Graft for Use in the Replacement of the Aortic Arch and Concomitant Treatment of an Aneurysm/Dissection of the Descending Aorta in the Frozen Elephant Trunk Procedure
NCT ID: NCT01541410
Last Updated: 2013-07-15
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
PHASE1/PHASE2
34 participants
INTERVENTIONAL
2010-05-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Thoraflex Hybrid Post-Market Study
NCT03414866
Medical & Economical Evaluation of Fenestrated & Branched Stent-grafts to Treat Complex Thoracal Abdominal Aneurysms
NCT01354821
Open Repair Versus Branched Endograft Repair for Treatment of Residual Chronic Aortic Arch Dissection During Follow-up After Open Type A Acute Ascending Aorta Replacement: Results From an International Multicenter Study.
NCT04014907
Further Evaluation of Safety and Performance of the NEXUS Aortic Arch Stent Graft System and the Custom-Made NEXUS Multibranch™ Aortic Arch Stent Graft System
NCT05636527
International Retrospective Study of Pipeline Embolization Device
NCT01558102
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The traditional prosthesis component is representative of current Gelweave™ product. It is a woven polyester graft, crimped to maintain the lumen and gel coated to ensure that it will seal immediately. The stented section of the graft is a self-expanding endoprosthesis constructed of a thin wall woven polyester and Nitinol ring stents, which are attached to fabric with braided polyester sutures.
The delivery system is a central catheter comprised of a stainless steel braided, Isoplast-Pebax co-extrusion which has been locally strengthened to provide adequate guidewire lumen and sufficient stiffness to deploy the device. The outer sheath is 24Fr extruded PTFE with a groove to provide a localised splitting during deployment. The handle components are moulded in K-Resin \& thermoplastic polyurethane to fulfil the functional requirements of the product.
The compacted endoprosthesis is placed through the opened aortic arch and deployed leaving the stented section positioned inside the descending aorta. The device is then released from the delivery system and the handle components removed leaving the full graft in situ and correctly positioned. This allows the surgeon to complete the aortic arch repair as required.
The materials of the endoprosthesis section, and of the traditional prosthesis section of the Hybrid Device are identical to those of current Vascutek product (Anaconda™ Stent Graft System - endoprosthesis; and Gelweave™ - standard vascular graft). All materials used in the delivery system are well established in medical applications.
The Vascutek Ltd. Hybrid Device is produced using established manufacturing and Quality Control methodologies in an ISO 9001 and ISO 13485 certified system. The Hybrid Device is provided sterile for single use only. The method of sterilisation is ethylene oxide.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
TREATMENT
NONE
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Vascutek Hybrid Graft
Single Group Assignment
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. Patient must have agreed to participate voluntarily and have signed and dated an Ethics Committee approved Patient Informed Consent
3. Patient is able and willing to comply with the protocol and associated follow-up requirements
Exclusion Criteria
2. Endocarditis or active infective disorder of the aorta
3. Patients unwilling to give informed consent
29 Years
79 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Vascutek Ltd.
INDUSTRY
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Division of Thoracic and Cardiovascular Surgery, Hannover Medical School
Hanover, , Germany
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
HYBRID-001
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.