A Comparison of Wear Among Mobile and Fixed Bearing Knee Replacements

NCT ID: NCT01165957

Last Updated: 2012-08-01

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Total Enrollment

24 participants

Study Classification

OBSERVATIONAL

Study Start Date

2010-06-30

Study Completion Date

2012-05-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The purpose of this study is to determine the amount of polyethylene wear associated with knee replacement designs that incorporate either a fixed or mobile bearing. Tibial polyethylene inserts retrieved from modular total knee replacements during revision operations will be analyzed by obtaining micro-CT images of the retrieved inserts. The components of total volumetric polyethylene loss, including wear associated with the medial articular, lateral articular and backside regions of the insert be quantified by comparing the worn insert with an unworn control. The investigators hypothesize that the fixed bearing inserts where the polyethylene is locked to the metal baseplate will demonstrate more volumetric wear than the mobile bearing inserts that are designed to slide or rotate on the metal baseplate.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Polyethylene wear is a major factor limiting the longevity of total knee arthroplasty. Evaluation of the volumetric wear of explanted polyethylene tibial inserts can provide valuable insight into the performance of different designs. Current technologies available to measure the volumetric wear of tibial inserts include gravimetric techniques, coordinate measuring machines (CMM), laser-scanning, and micro-CT.

In this study, we will employ micro-CT to determine volumetric wear because it allows us to obtain high-resolution three-dimensional images of the entire insert volume, including the surfaces as well as the interior of the insert. The micro-CT images will be used to reconstruct the entire three-dimensional geometry of the insert (including subsurface voids) and we will use image analysis software to partition the reconstructed insert into discrete regions (i.e. medial/lateral articulating surfaces, backside, and post), allowing us to determine how various regions contribute to total implant wear. By subdividing the insert into discrete regions, our analysis techniques will also enable us to account for material removed from the insert during explantation when evaluating implant wear. By comparing retrieved inserts with unworn controls using three-dimensional image analysis software, we will also quantify plastic deformation by measuring the volume of material that has deformed outside the confines of the control insert. Additionally, inspection of shape differences between the worn and unworn specimens will enable us to distinguish between implant wear, plastic deformation and volume differences associated with manufacturing tolerances. Although partial voluming effects can make edge detection challenging, high resolution micro-CT images tend to minimize these effects and we will use gravimetric measurements to determine an insert-specific Hounsfield threshold that will be used to define the image volume for each specimen. We will subsequently validate the accuracy of the reconstructed insert volume derived from the micro-CT image by comparing it with linear measurements from the actual specimen at several discrete locations.

The use of micro-CT scans to evaluate the in vivo volumetric wear associated with different designs will enable accurate measurement of volumetric polyethylene loss from different regions of the insert. This information will provide a better understanding of the clinical outcome associated with different design strategies and provide data to guide future development efforts. We hypothesize that fixed bearing inserts, where the polyethylene is locked to the metal baseplate, will demonstrate more volumetric wear than the mobile bearing inserts that are designed to slide or rotate on the metal baseplate.

Articular side wear will be measured by registering micro-CT images from retrieved and control inserts on unworn portions of the articular surface using the Analyze image analysis software (Mayo Biomedical Imaging Resource, Rochester, MN). Differences in volume among the retrieved and unworn control inserts will be evaluated accounting for plastic deformation that may occur in vivo. Volumetric wear for the entire insert and subregions will be calculated by subtracting the volume of plastic deformation (corresponding to regions of the retrieved insert outside the boundaries of the control insert) from the volume of material lost within the confines of the original insert geometry. We will compare wear among the mobile and fixed bearings using an Independent Sample t-test or Mann-Whitney U, depending on the distribution of the data. We will also use multiple linear regression analysis to examine the relationship between insert wear and other variables, including time in vivo, terminal sterilization technique for the insert and patient-related factors such as gender, age, and body mass index (BMI).

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Osteoarthritis

Keywords

Explore important study keywords that can help with search, categorization, and topic discovery.

Knee replacement Mobile and fixed bearings Volumetric wear Micro-CT analysis Articular and backside wear

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

CASE_CONTROL

Study Time Perspective

RETROSPECTIVE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Mobile bearings

Tibial polyethylene inserts retrieved from total knee replacements where the insert is designed to slide or rotate on the metal baseplate.

No interventions assigned to this group

Fixed bearings

Tibial polyethylene inserts retrieved from total knee replacements where the insert is locked to the metal baseplate.

No interventions assigned to this group

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* DePuy mobile and fixed bearing polyethylene tibial inserts retrieved after at least 12 months in vivo.
* Inserts terminally sterilized by gas plasma or with gamma radiation in oxygen-free barrier packaging.

Exclusion Criteria

* Inserts that were sterilized by gamma radiation and exposed to oxygen in packaging.
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

DePuy Orthopaedics

INDUSTRY

Sponsor Role collaborator

Anderson Orthopaedic Research Institute

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

C. Anderson Engh, Jr., MD

Principal Investigator

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Robert H Hopper, Jr., PhD

Role: STUDY_DIRECTOR

Anderson Orthopaedic Research Institute

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Anderson Orthopaedic Research Institute

Alexandria, Virginia, United States

Site Status

Countries

Review the countries where the study has at least one active or historical site.

United States

References

Explore related publications, articles, or registry entries linked to this study.

McEwen HM, Barnett PI, Bell CJ, Farrar R, Auger DD, Stone MH, Fisher J. The influence of design, materials and kinematics on the in vitro wear of total knee replacements. J Biomech. 2005 Feb;38(2):357-65. doi: 10.1016/j.jbiomech.2004.02.015.

Reference Type BACKGROUND
PMID: 15598464 (View on PubMed)

Jennings LM, Bell CI, Ingham E, Komistek RD, Stone MH, Fisher J. The influence of femoral condylar lift-off on the wear of artificial knee joints. Proc Inst Mech Eng H. 2007 Apr;221(3):305-14. doi: 10.1243/09544119JEIM215.

Reference Type BACKGROUND
PMID: 17539585 (View on PubMed)

Related Links

Access external resources that provide additional context or updates about the study.

http://aori.org

Website for Anderson Orthopaedic Research Institute

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

Study #09010

Identifier Type: OTHER_GRANT

Identifier Source: secondary_id

AORI2010-0102

Identifier Type: -

Identifier Source: org_study_id