Spine Research With Roentgen Stereophotogrammetric Analysis
NCT ID: NCT00493558
Last Updated: 2013-02-20
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
PHASE4
17 participants
INTERVENTIONAL
2007-07-31
2012-06-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Pivotal Study of rhBMP-2/ACS/Allograft Bone Dowel for Anterior Lumbar Interbody Fusion in Patients With Symptomatic Degenerative Disc Disease
NCT01494493
A Pilot Study of rhBMP-2/ACS/Allograft Bone Dowel for Anterior Lumbar Interbody Fusion in Patients With Symptomatic Degenerative Disc Disease
NCT01494428
Pilot Study of rhBMP-2/ACS/LT-CAGE® for Anterior Lumbar Interbody Fusion in Patients With Degenerative Disc Disease
NCT01491373
Pilot Study of rhBMP-2/BCP in Patients With Spinal Degeneration With Instability Requiring Surgical Fusion
NCT01495234
Advanced Materials Science in XLIF Study
NCT03649490
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Four major intervertebral cages have been approved by the Food and Drug Administration (FDA) for use in humans: the Brantigan Interbody fusion Cage, the Ray Threaded Fusion Cage, the Bagby and Kuslich cage, and, most recently, the Trabecular Metal™ Cage. Comprised of 98 percent tantalum and 2 percent vitreous carbon, Trabecular Metal™ has the highest coefficient of friction of any implant material on the market, allowing for optimal initial implant-bone fit. Furthermore, the unique porous structure of Trabecular Metal™ provides significantly more space for tissue ingrowth to occur, facilitating a more cohesive implant-bone interface as well as long-term stability of the implant.
Long-term follow up data on the efficacy of the Brantigan Interbody fusion cage, Ray Threaded Fusion cage, and Bagby and Kuslich cages are limited, with the most rigorous studies (i.e. controlled prospective studies) typically providing outcomes approximately 2 years post-surgery. Overall, these studies show that, while existing intervertebral cages have made significant advances in terms of addressing the disadvantages associated with traditional bone grafting/fixation techniques, problems continue to persist. Through comprehensive and accurate clinical evaluation of the Trabecular Metal™ intervertebral cage, the Research Team hopes to document advances in the PLIF technique, thereby informing current research as well as clinical practice.
The primary goal of the proposed research is to gather data on the clinical efficacy of the Trabecular Metal™ Posterior Lumbar Interbody Fusion (PLIF) cage with pedicle screw instrumentation for the treatment of one-level lumbar spine fusions. Based on this pilot data, we hope to establish a level of acceptable clinical performance for the Trabecular Metal™ cage, a benchmark against which subsequent investigations can be compared.
Direct surgical exploration is considered the most reliable method for accurately determining fusion success, both from a structural and functional perspective, following spinal fusion surgery. Unfortunately, this method is highly invasive, costly and seldom used. Furthermore, surgical exploration does not provide any longitudinal information as to the stability of the implant, including the monitoring of any occurrence of migration.
In contrast, Roentgen Stereophotogrammetric Analysis(RSA)can detect the presence or absence of mobility between intervertebral segments (i.e. functional stability of the fusion) with a high degree of accuracy. RSA is a radiographic technique that uses small tantalum balls implanted into the patient's bone to measure micromotion (\<1 mm) at the bone - implant interface, something which is not possible to do reliably using regular x-ray techniques. RSA provides a method for detecting inferior implant designs or cement formulations using only a small number of patients before release of these products into large clinical trials.
RSA has been in use for several decades,and its safety is well documented.A computerized, digital RSA system has recently been installed and calibrated at our center. Its measurement capabilities have been rigorously validated, and it is currently being used to assess a new knee implant design. Expansion of the system to include spine RSA can be easily accomplished.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
TREATMENT
NONE
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Trabecular Metal Intervertebral Cage with RSA beads
Roentgen Stereophotogrammetric Analysis beads will be inserted at time of implant of the Trabecular Metal Intervertebral Cage.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Clinical and radiologic history of spondylolisthesis (no greater than grade 1)
* Spinal stenosis for which conservative treatment has failed
* Degenerative disc disease, characterized by one or more of the following:
* instability (defined as angular motion \> 5° and/or translation \> 4mm, based on Flex/Ext radiographs)
* osteophyte formation
* decreased disc height
* thickening of ligamentous tissue
* disc degeneration or herniation
* facet joint degeneration
Exclusion Criteria
* Non-fusion surgery at the involved level
* Previously diagnosed with osteopenia, osteoporosis, or osteomalacia to a degree that spinal instrumentation would be contraindicated
* Patients with a highly-communicable disease, inflammatory or auto-immune based joint disease
* Those with a history of endocrine or metabolic disorders known to affect osteogenesis (e.g. Paget's disease, renal osteodystrophy, Ehlers-Danios syndrome or osteogenesis imperfecta)
* Patients with a documented titanium or tantalum alloy allergy or intolerance
* Patients currently receiving active treatment for cancer or treatment with steroids such as cortisone
* Patients with significant medical history that, in the Investigator's opinion, would not make them a good study candidate
20 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Zimmer Biomet
INDUSTRY
Nova Scotia Health Authority
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
William Oxner
Principal Investigator
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Dr. Wm Oxner, M.D.
Role: PRINCIPAL_INVESTIGATOR
Capital District Health Authority, QEII Health Science Centre, & Dalhousie University, Halifax. Nova Scotia,Canada
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Capital District Health Authority, QEII Health Sciences Centre,& Dalhousie University
Halifax, Nova Scotia, Canada
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
CDHA018
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.