Does An Abnormal PFA 100 Predict Bleeding After Renal Biopsy?
NCT ID: NCT00334204
Last Updated: 2013-08-01
Study Results
Outcome measurements, participant flow, baseline characteristics, and adverse events have been published for this study.
View full resultsBasic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
TERMINATED
PHASE4
58 participants
INTERVENTIONAL
2004-08-31
2008-12-31
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The purpose of this study is to determine whether an abnormal Platelet Function Analyser-100, a test which determines platelet function, is an accurate predictor of bleeding in those with chronic kidney disease.
All patients admitted for renal biopsy will be offered enrollment in this study. Initial data to include the following will be obtained: age, sex, weight, serum creatinine, activated Prothrombin Time/activated Partial Thromboplastin Time, Complete Blood Count and Platelet Function Analyser-100 closure times. Participants will then be placed in groups (cohorts) based on their calculated Glomerular Filtration Rate and if less than 30 cc/min, Desmopressin \[Brand Name: DDAVP\] (a drug which appears to improve platelet function) will be given. Post-procedure, participants will be monitored for bleeding by obtaining a Complete Blood Count (CBC) 4 hours and approximately 16 hours post-procedure and monitoring urine for blood. The pre- and post-procedure hematocrit and a post biopsy renal ultrasound will be used to determine whether an abnormal Platelet Function Analyser-100 closure time was predictive of a decrease in hematocrit
There are no additional risks of participation in this study. This study would only involve obtaining additional blood but it would be obtained with blood that would otherwise be obtained prior to renal biopsy. There is no direct benefit from this study to enrolled participants. Besides the Platelet Function Analyser-100 blood test, the patients undergoing renal biopsies will undergo the procedure and post-procedure monitoring per standard of care for renal biopsy at this institution.
Inclusion criteria:
Will offer enrollment to essentially all patients undergoing standard percutaneous renal biopsy here at the University Medical Center. These are:
age 18-80, Body Mass Index\>35, Modification of Diet in Renal Diseases (DMDRD)formula-based calculated Glomerualar Filtration Rate (GFR)\>10cc/minute, Hematocrit \>25, platelet count \>100, normal aPT/aPTT,
Exclusion criteria:
essentially the contraindications to a standard percutaneous renal biopsy) known bleeding disorder, history of prior bleeding with procedure or known ongoing bleeding at the time of the procedure, Hematocrit \<25, Platelet count \<100, abnormal activated Prothrombin Time (aPT)/activated Partial Thromboplastin Time (aPTT) pre biopsy, small kidney(s) \< 8.0 cm, multiple bilateral renal cyst or masses, hydronephrosis, active urinary tract infection, recent nonsteroidal anti-inflammatory drug use.
Risk:
The Platelet Function Analyser 100 will require an additional 5-10cc of blood to be drawn. No additional sticks will be done since generally prior to biopsy the patients will have Complete Blood Count, aPT/aPTT and chemistries drawn.
Possible benefits to patients:
There will likely be no benefit for the individual patient. The Platelet Function Analyser 100 is a relatively new test for determining platelet dysfunction and there have been limited studies in dialysis patients. However to date, there have been no studies in those with chronic kidney disease. If a correlation is found between an abnormal Platelet Function Analyser and bleeding instead of giving all patients with compromised Glomerular Filtration Rate, desmopressin, only those with abnormal Platelet Function Analyser would be given desmopressin. In essence, this would decrease the patient incurred expenses of hospitalization. This test may also point out those patients who are high risk for bleed post renal biopsy and may ultimately alter length of in hospital monitoring of patients post biopsy.
Other benefit of this test is that it is a noninvasive, rapid and does not require specialized training to perform the test.
Alternatives:
In lieu of checking Platelet Function Analyser 100, a bleeding time could be done but it has been demonstrated in multiple studies to poorly correlate with bleeding. The results for bleeding time often vary because it is a difficult test to reproduce. Currently, there is no standard, or acceptable, pre-renal biopsy platelet function test done at this Institution.
Consent process:
The patient who will be enrolled in this study have already agreed to undergo a renal biopsy which will be the reason for their hospital admission. They will be allowed to discuss with family members via phone or if they are present at the hospital but it will not be feasible for patients to be allowed to take the consent home and defer biopsy for discussion.
The investigator will have a discussion about the Platelet Function Analyser 100 with all prospective participants prior to renal biopsy being performed. The discussion will include the risks and benefits of having the test performed. The patients will be allowed to ask questions. If consent is given then the Platelet Function Analyser-100 will be drawn.
Cost:
There will be no significant increase in cost. The reagent used to do the test is being donated and the Department of Pathology is willing to do the test without any additional charge to the patient.
Compensation to participants: none.
Data preservation and analysis:
The data obtained during this study will only be available to the Principal investigator and immediate study personnel.
The data will be kept by the Principal investigator in a secured location indefinitely.
The results of the Platelet Function Analyser testings will be in the medical record with the result of the other labs obtained during hospitalization.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Keywords
Explore important study keywords that can help with search, categorization, and topic discovery.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
DIAGNOSTIC
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Measure Platelet Function Analyser -100 (PFA-100)
measuring Platelet Function Analyser (PFA)-100 test (an in vitro platelet function test, in addition to the rest of the routine/uusal clinical care)
measuring Platelet Function Analyser-100 (PFA-100) platelet function before kidney biopsy
measuring Platelet Function Analyser (PFA) -100 platelet function before kidney biopsy
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
measuring Platelet Function Analyser-100 (PFA-100) platelet function before kidney biopsy
measuring Platelet Function Analyser (PFA) -100 platelet function before kidney biopsy
Other Intervention Names
Discover alternative or legacy names that may be used to describe the listed interventions across different sources.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
age 18-80, Body Mass Index (BMI) \<35, Modification of Diet in Renal Diseases (MDRD) calculated Glomerular Filtration Rate (GFR) \>10 cc/minute/1.73 m2, Hematocrit \>25, platelet count \>100,000/mm3, normal activated Prothrombin Time (aPT)/activated Partial Thromboplastin Time (aPTT).
Exclusion Criteria
\-
18 Years
80 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
University of Mississippi Medical Center
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Tibor Fulop
Associate Professor of Medicine
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Tibor Fulop
Role: PRINCIPAL_INVESTIGATOR
University of Mississippi Medical Center, Nephrology Division
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
University of Mississipppi Medical Center, Adult Hospital
Jackson, Mississippi, United States
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Islam N, Fulop T, Zsom L, Miller E, Mire CD, Lebrun CJ, Schmidt DW. Do platelet function analyzer-100 testing results correlate with bleeding events after percutaneous renal biopsy? Clin Nephrol. 2010 Mar;73(3):229-37. doi: 10.5414/cnp73229.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
2004-0092
Identifier Type: -
Identifier Source: org_study_id