Computer-Aided Water Exchange Colonoscopy With and Without Linked-Color Imaging for Detection of Clinically Significant Serrated Lesions

NCT ID: NCT07127471

Last Updated: 2025-11-20

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

RECRUITING

Clinical Phase

NA

Total Enrollment

1090 participants

Study Classification

INTERVENTIONAL

Study Start Date

2025-11-17

Study Completion Date

2027-07-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The goal of this clinical trial is to compare the detection rate of clinically significant serrated lesions (CSSL) in participants undergoing water exchange (WE) colonoscopy with artificial intelligence (AI)-based computer-aided detection (CADe) for screening, surveillance, diagnosis for symptoms, or referred owing to a positive fecal immunochemical test (FIT) or guaiac fecal occult blood test (gFOBT) result. There will be two arms in this study: WE with AI-assisted CADe (WEAID) control and WEAID plus linked-color imaging (LCI). The main question it aims to answer is whether the addition of LCI into WEAID colonoscopy increases CSSL detection rate. Both groups use water instead of air to insert the colonoscope into the cecum. The control method uses CADe to help detect colonic lesions. The study method uses a combination of CADe and LCI to detect lesions. Researchers will compare CSSL detection rate to see if the addition of LCI increases the detection of CSSL during CADe-assisted WE colonoscopy.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

This will be a multicenter, unblinded investigators, prospective randomized controlled trial (RCT). Randomization (1:1 to WEAID alone and WEAID plus LCI) will be based on computer generated random numbers placed inside opaque sealed envelopes. The envelope (in pre-arranged order) will be opened to reveal the code when the colonoscopist is ready to insert the endoscope to begin the examination. This will be a comparison of two different methods with two arms (WEAID, WEAID-LCI) to see which one is better at detecting CSSL.

Patient recruitment will be conducted at 4 hospitals: University of Montreal Medical Center (CHUM), Quebec, Canada; Evergreen General Hospital, Taoyuan, Taiwan; King Chulalongkorn Memorial Hospital, Bangkok, Thailand; and Ospedale Valduce, Como, Italy. The study period is expected to be 2 years (from August 2025 to July 2027).

Patients aged 40-80 y/o at average risk of colorectal cancer who are willing to participate will sign an informed consent before starting the colonoscopy procedure. Separate parallel randomization will be set up at each site, stratified by investigator and indication of colonoscopy (screening, surveillance, diagnostic, or positive FIT or gFOBT result). Mode of sedation will include no sedation, on-demand sedation, conscious sedation or full sedation with propofol. Randomization will be carried out by computer-generated sequences.

The study employs standard high-definition colonoscopy video processors with integrated CADe system (CAD-EYE, EW10-EC02, Fujifilm). The ELUXEO 7000 system (Fujifilm) will be used. The same endoscopist performs the insertion and withdrawal of colonoscopy. The colonoscope will be inserted with WE method, instead of air insufflation. WE involves simultaneous infusion of distilled water to facilitate luminal expansion and suction of unclean water.

Control Method: One arm of the study will include CADe as the control method. The CADe system will be activated during the withdrawal phase of the procedures, and it will provide real-time output in the form of a bounding box whenever the CADe device identifies a suspected polyp.

Study method: The other arm entails the addition of a commercially available image-enhanced LCI technique (Fujifilm) to the CADe system. LCI will be activated during the withdrawal phase to enhance visualization of the lesions.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Sessile Colonic Polyp Serrated Lesion Sessile Serrated Lesion Colon Adenomas

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

SCREENING

Blinding Strategy

DOUBLE

Participants Outcome Assessors

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Water exchange with AI-assisted detection

The study employs standard high-definition colonoscopy video processors with integrated CADe system (CAD-EYE, EW10-EC02, Fujifilm) The ELUXEO 7000 system (Fujifilm) will be used in this study. During the insertion phase of water exchange (WE) colonoscopy, the air pump will be turned off, and the colon will be irrigated with warm water, using a flushing pump. WE involves simultaneous infusion of distilled water to facilitate luminal expansion and suction of unclean water. Withdrawal will begin with the patient in the left lateral position. Consistent techniques, ensuring adequate luminal distention and comprehensive fold examination, will be used. The CADe device will be activated during the withdrawal phase of the procedures, and it will provide real-time output in the form of a bounding box whenever the CADe device identifies a suspected polyp. All participating endoscopists possess experience and expertise in CADe systems, ensuring readiness before study initiation.

Group Type ACTIVE_COMPARATOR

Water exchange with AI-assisted detection

Intervention Type DEVICE

The study employs standard high-definition colonoscopy video processors with integrated CADe system (CAD-EYE, EW10-EC02, Fujifilm) The ELUXEO 7000 system (Fujifilm) will be used in this study. During the insertion phase of water exchange (WE) colonoscopy, the air pump will be turned off, and the colon will be irrigated with warm water, using a flushing pump. WE involves simultaneous infusion of distilled water to facilitate luminal expansion and suction of unclean water. Withdrawal will begin with the patient in the left lateral position. Consistent techniques, ensuring adequate luminal distention and comprehensive fold examination, will be used. The CADe device will be activated during the withdrawal phase of the procedures, and it will provide real-time output in the form of a bounding box whenever the CADe device identifies a suspected polyp. All participating endoscopists possess experience and expertise in CADe systems, ensuring readiness before study initiation.

Water exchange with AI-assisted detection and LCI

The study employs high-definition colonoscopy video processors with integrated CADe (CAD-EYE, EW10-EC02, Fujifilm) and LCI systems (Fujifilm).The ELUXEO 7000 system will be used . During the insertion phase of water exchange (WE) colonoscopy, the air pump will be turned off, and the colon will be irrigated with warm water, using a flushing pump. WE involves simultaneous infusion of distilled water to facilitate luminal expansion and suction of unclean water. Withdrawal will begin with the patient in the left lateral position. Consistent techniques, ensuring adequate luminal distention and comprehensive fold examination, will be used. The CADe and LCI devices will be activated during the withdrawal phase of the procedures, and it will provide real-time output in the form of a bounding box whenever the CADe device identifies a suspected polyp. All participating endoscopists possess experience and expertise in CADe and LCI systems, ensuring readiness before study initiation.

Group Type EXPERIMENTAL

Water exchange with AI-assisted detection and LCI

Intervention Type DEVICE

The study employs high-definition colonoscopy video processors with integrated CADe (CAD-EYE, EW10-EC02, Fujifilm) and LCI systems (Fujifilm).The ELUXEO 7000 system will be used . During the insertion phase of water exchange (WE) colonoscopy, the air pump will be turned off, and the colon will be irrigated with warm water, using a flushing pump. WE involves simultaneous infusion of distilled water to facilitate luminal expansion and suction of unclean water. Withdrawal will begin with the patient in the left lateral position. Consistent techniques, ensuring adequate luminal distention and comprehensive fold examination, will be used. The CADe and LCI devices will be activated during the withdrawal phase of the procedures, and it will provide real-time output in the form of a bounding box whenever the CADe device identifies a suspected polyp. All participating endoscopists possess experience and expertise in CADe and LCI systems, ensuring readiness before study initiation.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Water exchange with AI-assisted detection

The study employs standard high-definition colonoscopy video processors with integrated CADe system (CAD-EYE, EW10-EC02, Fujifilm) The ELUXEO 7000 system (Fujifilm) will be used in this study. During the insertion phase of water exchange (WE) colonoscopy, the air pump will be turned off, and the colon will be irrigated with warm water, using a flushing pump. WE involves simultaneous infusion of distilled water to facilitate luminal expansion and suction of unclean water. Withdrawal will begin with the patient in the left lateral position. Consistent techniques, ensuring adequate luminal distention and comprehensive fold examination, will be used. The CADe device will be activated during the withdrawal phase of the procedures, and it will provide real-time output in the form of a bounding box whenever the CADe device identifies a suspected polyp. All participating endoscopists possess experience and expertise in CADe systems, ensuring readiness before study initiation.

Intervention Type DEVICE

Water exchange with AI-assisted detection and LCI

The study employs high-definition colonoscopy video processors with integrated CADe (CAD-EYE, EW10-EC02, Fujifilm) and LCI systems (Fujifilm).The ELUXEO 7000 system will be used . During the insertion phase of water exchange (WE) colonoscopy, the air pump will be turned off, and the colon will be irrigated with warm water, using a flushing pump. WE involves simultaneous infusion of distilled water to facilitate luminal expansion and suction of unclean water. Withdrawal will begin with the patient in the left lateral position. Consistent techniques, ensuring adequate luminal distention and comprehensive fold examination, will be used. The CADe and LCI devices will be activated during the withdrawal phase of the procedures, and it will provide real-time output in the form of a bounding box whenever the CADe device identifies a suspected polyp. All participating endoscopists possess experience and expertise in CADe and LCI systems, ensuring readiness before study initiation.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Male and female patients aged 40-80 years scheduled for average-risk screening colonoscopy, post-polypectomy surveillance, diagnosis for gastrointestinal symptoms (including unexplained iron deficiency anemia and clinically significant diarrhea of unexplained origin), or referred for colonoscopy owing to a positive fecal immunochemical test (FIT) or guaiac fecal occult blood test (gFOBT) result.

Exclusion Criteria

* familial adenomatous polyposis and hereditary non-polyposis CRC syndrome
* personal history of serrated polyposis syndrome
* personal history of CRC
* history of inflammatory bowel disease
* previous colonic resection
* overt gastrointestinal bleeding
* emergency colonoscopy or inpatients
* planned EMR or ESD of large polyps
* colon stricture or obstruction
* contraindications to colonoscopy (eg, acute diverticulitis or toxic megacolon)
* antithrombotic therapy precluding complete polyp resection
* American Society of Anesthesiology classification of physical status \>3
* pregnant women or women planning pregnancy
* refusal to provide a written informed consent
Minimum Eligible Age

40 Years

Maximum Eligible Age

80 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Centre hospitalier de l'Université de Montréal (CHUM)

OTHER

Sponsor Role collaborator

King Chulalongkorn Memorial Hospital

OTHER

Sponsor Role collaborator

Ospedale Valduce, Como

UNKNOWN

Sponsor Role collaborator

Evergreen General Hospital, Taiwan

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Chi-Liang Cheng, MD

Role: STUDY_CHAIR

Evergreen General Hospital, Taoyuan

Rungsun Rerknimitr, MD

Role: PRINCIPAL_INVESTIGATOR

Center of Excellence for Innovation and Endoscopy in Gastrointestinal Oncology, King Chulalongkorn Memorial Hospital

Daniel von Renteln, MD

Role: PRINCIPAL_INVESTIGATOR

Research, Gastroenterology Division, University of Montreal Medical Center (CHUM)

Franco Radaelli, MD

Role: PRINCIPAL_INVESTIGATOR

Gastroenterology Unit, Ospedale Valduce

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

University of Montreal Medical Center (CHUM)

Montreal, Quebec, Canada

Site Status NOT_YET_RECRUITING

Ospedale Valduce

Como, , Italy

Site Status NOT_YET_RECRUITING

Evergreen General Hospital

Taoyuan District, , Taiwan

Site Status RECRUITING

King Chulalongkorn Memorial Hospital

Bangkok, , Thailand

Site Status NOT_YET_RECRUITING

Countries

Review the countries where the study has at least one active or historical site.

Canada Italy Taiwan Thailand

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Chi-Liang Cheng, MD

Role: CONTACT

+886 919 768058

Rungsun Rerknimitr, MD

Role: CONTACT

+66 81 902 6633

Facility Contacts

Find local site contact details for specific facilities participating in the trial.

Daniel von Renteln, MD

Role: primary

5148908000 ext. 30912

Franco Radaelli, MD

Role: primary

+39 031 324171

Chi-Liang Cheng, MD

Role: primary

0919768058

Rungsun Rerknimitr, MD

Role: primary

+66 81 902 6633

References

Explore related publications, articles, or registry entries linked to this study.

Anderson JC, Hisey W, Mackenzie TA, Robinson CM, Srivastava A, Meester RGS, Butterly LF. Clinically significant serrated polyp detection rates and risk for postcolonoscopy colorectal cancer: data from the New Hampshire Colonoscopy Registry. Gastrointest Endosc. 2022 Aug;96(2):310-317. doi: 10.1016/j.gie.2022.03.001. Epub 2022 Mar 8.

Reference Type BACKGROUND
PMID: 35276209 (View on PubMed)

Anderson JC, Rex DK, Mackenzie TA, Hisey W, Robinson CM, Butterly LF. Higher Serrated Polyp Detection Rates Are Associated With Lower Risk of Postcolonoscopy Colorectal Cancer: Data From the New Hampshire Colonoscopy Registry. Am J Gastroenterol. 2023 Nov 1;118(11):1927-1930. doi: 10.14309/ajg.0000000000002403. Epub 2023 Jul 7.

Reference Type BACKGROUND
PMID: 37417792 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

WEAID with LCI

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.