Accuracy of Computer Guided Implant Placement in Edentulous Mandible A Three-Dimensional In Vitro Study

NCT ID: NCT06990360

Last Updated: 2025-05-30

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Total Enrollment

5 participants

Study Classification

OBSERVATIONAL

Study Start Date

2017-05-20

Study Completion Date

2024-09-20

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Five stryofoam mandibles were included in this study to assess the accuracy of using computer guided surgical stent in placement of dental implants. The mandibles were CBCT scanned and imported to 3diagnosys software to implant planning. 8 implants were placed in each mandible virtually, 4 anterior implants and 4 posterior implants were placed. The plan was exported as STL file to be imported to the CAD software for designing of the stent. The surgical stent is printed using Micro DGP printer and invision tec e-shell 600 clear resin was used. Stainless steel sleeves were placed in the surgical guide then placed in ethanol 99% to remove the excess monomer.

The stent in placed over the mandible and sequential drilling was done until the desired osteotomies width was approached followed by the placement of the implants. Post-operative CBCT was done for the mandible including the implants to assess the accuracy, angulation and position of the placed implants

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Edentulous Alveolar Ridge Edentulous Alveolar Ridge In Mandible

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

CASE_CONTROL

Study Time Perspective

CROSS_SECTIONAL

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

CBCT Scanning

The Styrofoam mandibles were scanned using CBCT, which was performed for each mandible pre-operatively, the raw DICOM data set obtained from the CBCT scanning were imported to a special third-party software\* for secondary reconstruction.

Intervention Type DIAGNOSTIC_TEST

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Five styrofoam mandibles

Exclusion Criteria

* no fractures or pathology
Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Eslam Nashaat Saied Ahmed Mohamed

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Eslam Nashaat Saied Ahmed Mohamed

Post graduate student

Responsibility Role SPONSOR_INVESTIGATOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

future university in Egypt

Cairo, Giza Governorate, Egypt

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Egypt

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

Future University

Identifier Type: OTHER

Identifier Source: secondary_id

FUE.REC (13)/12-2017

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.