Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
20 participants
INTERVENTIONAL
2023-04-08
2025-02-20
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
This prospective clinical trial will involve 14 edentulous patients who will receive two implants in the premolar area. Patients will be randomly assigned to two groups: Group A will receive metal bar overlays, and Group B will receive Peek bar overlays. The patients will be evaluated at baseline,one month ,6 month and 12 month The following parameters will be evaluated:
1. Wear of nylon cap: The wear of the nylon cap will be evaluated using a digital microscope at each follow-up visit.
2. Patient satisfaction: Patients will be asked to rate their satisfaction with the overdentureResults: Metal group showed significantly higher roughness and volumetric changes than PEEK regarding baseline, after 3 months, after 6 months, and after 9 months. and there was insignificant difference between them after 12 months as P=0.11.Patient satisfaction scores were significantly higher in the PEEK group, particularly in retention, stability, comfort, and speech domains at both six months and one year (p = 0.04). on a visual analogue scale (VAS) at each follow-up visit.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
The Effect of Clip Material on the Retention of Implant Supported Mandibular Overdenture
NCT06866067
Wear Assessment of Novel PEEK Telescopic Attachment for Overdenture
NCT06434142
Comparative Evaluation of Masticatory Efficiency of Implant Supported Overdenture
NCT05877092
Compare the Difference in Occlusal Force Distribution and Denture Retention Using 2 Different Denture Base Materials in Implant Retained Overdenture
NCT07250503
Wear of Vita Ambria Only Restoration Compared With IPS Emax Onlay Restoration
NCT05431465
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Patient selection All the patient involved in the study, they should have inclusion criteria as good bone quantity and quality especially in the anterior interforaminal region as detected by CBCT and sufficient inter-arch space, minimally 12-14 mm from the ridge to the occlusal plane. The diabetic patient or patient received radiation therapy, or with parafunctional habits, and smokers should be excluded from the study.
Diagnostic and pre-operative prosthetic preparation Following the prosthetic driven implant placement protocol, all the Eligible patients already had complete dentures, their dentures were checked for adaptation, fit, stability, and occlusion. And the other patients were not wearing upper and lower complete dentures , a new denture were fabricated .
Preliminary alginate impressions (Zhermack SpA ) using a perforated stock tray were recorded, Impressions were then poured into dental stone to obtain the diagnostic model. Occlusion blocks were constructed over the diagnostic models, followed by bite registration, try-in, then the inter arch space availability for the bar was evaluated on the casts using the putty-silicon-index (Kettenbach GmbH and Co. KG ) around the artificial teeth , a minimum 13-14 mm of vertical space is required for bar-retained overdentures and finally upper and lower denture (Acrostone Dental and Medical Supplie) was delivered . Radiographic stents were fabricated as a duplicate from the fabricated patient mandibular denture with radiopaque markers (gutta percha ,Meta Dental Corp Glendale, NY ) in the centre of the teeth to guide implant positioning.
The patient was scanned CBCT while wearing the radiographic stent in the proper seating position
Surgical phase. The radiographic stent was converted to a surgical stent by drilling holes at canine areas to determine the intended surgical sites . For both groups, all patient received two implants' DENTIS Co., LTD. 3.2 x 11.5 mm (bilaterally in the canine premolar region according to bone availability in the case. All implants were placed using a surgical guide and following two-stage surgical protocol. Covering screws were screwed into the implants 3 month of healing time. In the Prosthetic stage, after 3 months of ossointegration period, the implants were exposed to receive healing collars. After two weeks, the healing collars were removed, and the soft tissue was assessed for healing. Multiunit abutments were screwed at 30 Newtons using a torque wrench. To reduce settling effect, the multiunit abutment were retightened at least two or three times at 30N torque for 10 min interval.
For both groups, primary impressions (Zhermack SpA ) were made to fabricate a special tray with window at the implant area for open tray impression technique. For impression accuracy, the long transfers coping were splinted through self-cure acrylic resin. A single-stage impression technique (putty and light body) (Kettenbach GmbH and Co. KG ) was made using silicon impression material with the open custom tray (Acrostone cold cure acrylic material; Acrostone Co).The healing caps were replaced intraorally after the impression making. Analogs were screwed over the picked-up impression coping. The final impression was poured with extra hard dental stone. (Zhermack SpA ) To assure accuracy of the master cast, acrylic verification jig (Duralay, Prestige Dentl Products, UK Ltd ) was fabricated over the impression coping using a self-cure acrylic resin. Intraoral one screw test was applied to check passivity.
Computer-generated randomization was used to divide the patients into two equal groups (1:1). An implant-retained overdenture with a cobalt-chromium bar attachment was given to Group II (the metal bar group), and Group II (the PEEK bar group) was given an overdenture with a PEEK bar attachment.
Regarding Co-Cr metal bar group, in the master cast , the multiunit abutment were attached to the implant analogues and plastic abutments were adjusted , prepared and then wax pattern coping was customized on each abutment and was connected to a preformed castable bar 2.4mm Height, (Rhein 83) The bar was placed to be away from the anterior ridge by about 2-3 mm for proper hygiene measures. The wax pattern was then sprued and casted into cobalt- chromium alloy.
Regarding PEEK bar group, the master stone cast is scanned with external desktop scanner to produce an STL (Standard Tesellation Language) file for a virtual model using the CAD/CAM software (Medit 500i.). The design of the multiunit abutment and bar (Rhein Bar )was selected from the library of the CAD software. The bar dimensions were selected according to the study bar design .
After the data acquisition, the STL file was imported to the CAM part of the CAD/CAM system to mill PEEK bar from biological high-performance polymer (Bio-HPP) (BreCAM. BioHPP, Bredent GmbH \& Co.KG, Senden, Germany) block PEEK type. Multi-unit abutments were screwed to the implants and the PEEK bar was screwed to the abutments .
For all groups, Passive fit was checked visually by using a probe and by taking peri-apical radiographs to check for misfits. It was then confirmed by the one screw test which involved screwing the abutment on one side and checking the fit on the other terminal abutment.
For bar clip pickup ,all the overdentures seated and was examined intraorally, a space was made in its fitting surface that corresponded to the bar area. Condensation silicon impression material was used to block the space beneath the bar. The nylon clip (Rhein83 Italy) is firmly seated over the bar, autopolymerized acrylic resin(Acrostone cold cure acrylic material; Acrostone Co) was inserted in the relieved areas of the denture to pick up the retentive nylon clips intraorally ,the acrylic resin was set, the excess material was removed and the overdenture was delivered.
Measured outcomes Plastic clip wear and roughness were analyzed on overdenture insertion and after 3,6,9 month and 1 year of clinical usage in a 3D-surface analyzer system.27Fitting surface of denture with the nylon clip were photographed using USB Digital microscope with a built-in camera (Scope Capture Digital Microscope, Guangdong, China) connected with an IBM compatible personal computer using a fixed magnification of 120X.The images were recorded with a resolution of 1280 × 1024 pixels per image. Digital microscope images were cropped to 350 x 400 pixels using Microsoft office picture manager to standardize area of roughness measurement. WSxM software used for measure the average of heights of volumetric changes and surface roughness which expressed in μm, 28 a 3D image of the surface plastic clip was created ready for a 3-dimensional geometric analysis by the using a digital image analysis system (Image J 1.43U, National Institute of Health, USA). The intact unworn surface used as a reference.
Patients' satisfaction was evaluated After 6 month and 1 year on a scale from 1 to 10 according to the following criteria: (A) physical (stability and retention of denture), (B) Functional (chewing ability, speech ability, Pain, Comfort, Occlusion, Easiness of denture cleaning\& taste of food) and(C) Aesthetic factors (Appearance of dentures \& Self-image).
statistical analysis was performed with SPSS 16 ® (Statistical Package for Scientific Studies), Graph pad prism \& windows excel
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
TREATMENT
SINGLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
PEEK bar
Peek bar attachment with Nylon clip for retaining overdenture
PEEK dental bar
the master stone cast is scanned with external desktop scanner to produce an STL (Standard Tesellation Language) file for a virtual model using the CAD/CAM software (Medit 500i.). The design of the multiunit abutment and bar (Rhein Bar )was selected from the library of the CAD software. The bar dimensions were selected according to the study bar design .
After the data acquisition, the STL file was imported to the CAM part of the CAD/CAM system to mill PEEK bar from biological high-performance polymer (Bio-HPP) (BreCAM. BioHPP, Bredent GmbH \& Co.KG, Senden, Germany) block PEEK type. Multi-unit abutments were screwed to the implants and the PEEK bar was screwed to the abutments .
Metal bar
metal bar attachment to retain implant overdenture
Metal bar attachment
Co-Cr metal bar group, in the master cast , the multiunit abutment were attached to the implant analogues and plastic abutments were adjusted , prepared and then wax pattern coping was customized on each abutment and was connected to a preformed castable bar 2.4mm Height, (Rhein 83) The bar was placed to be away from the anterior ridge by about 2-3 mm for proper hygiene measures. The wax pattern was then sprued and casted into cobalt- chromium alloy.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
PEEK dental bar
the master stone cast is scanned with external desktop scanner to produce an STL (Standard Tesellation Language) file for a virtual model using the CAD/CAM software (Medit 500i.). The design of the multiunit abutment and bar (Rhein Bar )was selected from the library of the CAD software. The bar dimensions were selected according to the study bar design .
After the data acquisition, the STL file was imported to the CAM part of the CAD/CAM system to mill PEEK bar from biological high-performance polymer (Bio-HPP) (BreCAM. BioHPP, Bredent GmbH \& Co.KG, Senden, Germany) block PEEK type. Multi-unit abutments were screwed to the implants and the PEEK bar was screwed to the abutments .
Metal bar attachment
Co-Cr metal bar group, in the master cast , the multiunit abutment were attached to the implant analogues and plastic abutments were adjusted , prepared and then wax pattern coping was customized on each abutment and was connected to a preformed castable bar 2.4mm Height, (Rhein 83) The bar was placed to be away from the anterior ridge by about 2-3 mm for proper hygiene measures. The wax pattern was then sprued and casted into cobalt- chromium alloy.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
45 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Cairo University
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Doaa Amr Heshmat
Associate professor ,Cairo university ,Faculty of dentistry
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Cairo University Faculty of dentistry
Cairo, Cairo Governorate, Egypt
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
esthetic committee 49-7-32
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.