Comparing Monofocal IOLs in Highly Myopic Cataract Patients

NCT ID: NCT06905938

Last Updated: 2025-04-02

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

NOT_YET_RECRUITING

Total Enrollment

60 participants

Study Classification

OBSERVATIONAL

Study Start Date

2025-04-01

Study Completion Date

2026-05-30

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Comparison of Postoperative Outcomes in Patients with High Myopia Undergoing Cataract Surgery Implanted with Extended Depth of Focus Intraocular Lens (ICB00) and Monofocal Intraocular Lens (ZCB00)

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

In this study, we aim to compare the visual outcomes and quality of life between highly myopic patients with cataracts who receive implantation of extended depth of focus (EDOF) intraocular lenses (ICB00) and monofocal intraocular lenses (ZCB00). This is a case-control study, planning to recruit 64 highly myopic patients with cataracts, aged between 40 and 70, with 32 in each group. The primary endpoints of the study are the best-corrected visual acuity (BCVA) and defocus curve at 6 months postoperatively. Secondary endpoints include uncorrected visual acuity (UCVA), contrast sensitivity, intraocular pressure, and assessments of patient satisfaction and quality of life. These will be evaluated using standardized questionnaires such as the VF-14, the PRSIQ spectacle dependency scale, and reading speed tests to quantify changes in vision-related quality of life. Patients will undergo comprehensive ophthalmic examinations preoperatively and at 6 months postoperatively, including slit-lamp anterior segment examination, fundus examination, corneal topography, and intraocular pressure testing. Additionally, questionnaires will be used to assess patients' subjective satisfaction with visual improvement and spectacle needs in daily life. All data will be statistically analyzed to compare the effects of the two types of intraocular lenses. Continuous variables will be analyzed using t-tests or Mann-Whitney U tests, and categorical variables will be analyzed using chi-square tests. The level of statistical significance is set at p\<0.05. Through this study, we hope to determine whether the use of EDOF intraocular lenses provides better visual outcomes and quality of life compared to monofocal intraocular lenses in highly myopic patients with cataracts. The results of this study will provide a more scientific basis for the choice of intraocular lenses in clinical practice.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Cataract

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

CASE_ONLY

Study Time Perspective

PROSPECTIVE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

ICB00 implantation after cataract surgery.

Undergoing micro-incision cataract surgery with the implantation of an extended depth of focus (EDOF) intraocular lens (ICB).

no intervention

Intervention Type OTHER

no intervention

ZCB00 implantation after cataract surgery.

Performing micro-incision cataract surgery and implanting a ZCB (presumably an abbreviation specific to a certain type of intraocular lens) intraocular lens

no intervention

Intervention Type OTHER

no intervention

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

no intervention

no intervention

Intervention Type OTHER

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* 1: The patients are between 40 and 70 years old.

2: Ocular axis \> 26mm

3: Able to understand, cooperate and complete all follow-up.

Exclusion Criteria

* 1: Moderate and severe dry eye

2: There is macular degeneration complicated by high myopia.

3: Combined with other ophthalmic diseases

4: Previous history of ophthalmic surgery.

5: There are intraoperative or postoperative complications.
Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Wenzhou Medical University

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Yune Zhao

Vice president of Eye Hospital of Wenzhou Medical University

Responsibility Role PRINCIPAL_INVESTIGATOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Zhao Yune

Role: PRINCIPAL_INVESTIGATOR

Ethics Committee of the affiliated Ophthalmology Hospital of Wenzhou Medical University

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Ophthalmology and Optometry Hos

Hanzhou, Zhejian, China

Site Status

Countries

Review the countries where the study has at least one active or historical site.

China

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Zhao Yune

Role: CONTACT

13819707056

li siyan

Role: CONTACT

18813185262

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

H2025-014-K-13

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Photopic and Mesopic Multifocal IOL Performance
NCT06978556 ACTIVE_NOT_RECRUITING