Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
40 participants
INTERVENTIONAL
2022-10-01
2023-03-01
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
The primary objective is to determine the intra-rater and inter-rater reliability of the new test, measured using the intraclass correlation coefficient (ICC). The secondary objective is to compare the test's accuracy against an inertial motion sensor system and to quantify pelvic movement during the new test. To provide a comparative measure of pelvic motion, a subgroup of participants will also undergo the modified Ober test.
Forty healthy participants (20 males and 20 females) aged 18 to 30 years will be recruited. Each participant will undergo the new test, performed by two independent raters. A subset of participants will also be evaluated using the modified Ober test to assess differences in pelvic movement. Inertial sensors will be used to measure hip adduction angles and pelvic motion. Statistical analyses will include ICC calculations for reliability and paired t-tests to compare pelvic movement between the tests.
This study aims to establish a more precise and objective method for evaluating hip abductor extensibility, which may enhance clinical assessment and management of conditions associated with iliotibial band tension.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Gait Asymmetry Assessed Using Portable Gait Analysis System
NCT02489188
Reliability and Validity of a New Ankle Dorsiflexion Lunge Test Using a Level Laser.
NCT05403892
Hip Abductor Function During Trendelenburg Test
NCT05967611
Hip Abductor Strengthening With Proprioceptive Neuromuscular Facilitation
NCT05840523
Assessment of Torso Musculature and Hamstring Flexibility in Patients With Chronic Ankle Instability
NCT06925191
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Study Design The study follows a repeated-measures design, where intra-rater and inter-rater reliability are the primary outcomes, measured using the intraclass correlation coefficient (ICC). Secondary outcomes include the accuracy of the new test compared to an inertial motion sensor and an analysis of pelvic movement during the new test versus the modified Ober test in a subset of participants.
Participants A total of 40 healthy adults (20 males and 20 females), aged between 18 and 30 years, were recruited. The only exclusion criterion was the presence of symptomatic lower limb conditions that could interfere with the measurement, such as ligament injuries or degenerative joint diseases. No additional selection criteria were imposed, as existing literature does not categorize ITB extensibility based on age, sex, or pathology.
New Test Execution
The new test was originally proposed by Colonna (2012) and is designed to provide a more reliable and precise measurement of ITB tension. The test procedure consists of the following steps:
* Patient Positioning: The patient lies supine on the edge of a treatment table, with the non-tested leg flexed at the hip and knee, stabilizing the pelvis by resting the lateral malleolus against the table edge. The tested leg remains extended.
* Operator Positioning: The operator stands on the opposite side of the tested leg, stabilizing the knee of the non-tested leg with one hand and grasping the ankle of the tested leg with the other.
* Hip Adduction: The tested leg is gently adducted until a determined resistance is felt or the patient reports discomfort, ensuring no pain occurs.
* Measurement: The hip adduction angle is visually assessed and assigned a degree value.
This procedure is designed to enhance measurement accuracy by providing a clear and stable reference point while reducing the risk of excessive pelvic movement.
Modified Ober Test Execution A subset of participants underwent the modified Ober test for comparison. The patient lay on the side with the lower leg flexed at the hip and knee, while the upper leg remained extended. The therapist stabilized the pelvis while abducting and extending the hip, then allowing passive adduction. A goniometer was used to obtain quantitative measurements of hip adduction angles. The modified Ober test was chosen over the classic Ober test as it reduces the influence of knee flexors and patellar tension, providing a more specific assessment of ITB extensibility.
Phases of the Study
The study was conducted in six phases:
* Agreement on Measurement Methodology: Standardization of the new test and the modified Ober test procedures.
* Recruitment: Participants were enrolled at the OSCE (Osteopathic Spine Center Education) school of osteopathy in Bologna, Italy.
* Training Phase: Operators practiced test execution using a goniometer and dynamometer (100N force standardization), validated their visual assessments with inertial sensors, and refined their technique.
* Preliminary Testing for Agreement: Ten participants underwent preliminary tests to confirm measurement consistency.
* Official Data Collection: Each operator conducted the new test on both lower limbs of each participant at two time points (T0 and T1), with a minimum four-hour interval. The modified Ober test was performed on 20 participants by one operator for pelvic movement comparison.
* Data Analysis: Reliability and accuracy of the new test were assessed by comparing results to the modified Ober test and inertial sensor data.
Measurement Instruments
\- Hip adduction angles and pelvic rotation were measured using Xsens® inertial sensors. These wireless sensors, placed on the pelvis and thigh, provided real-time kinematic data to validate the accuracy of visual assessments and quantify pelvic movement.
Statistical Analysis
Data were analyzed using SPSS software. Reliability was assessed using ICC values, interpreted as follows:
Below 0.5: Poor reliability 0.5 to 0.75: Moderate reliability 0.75 to 0.9: Good reliability Above 0.9: Excellent reliability Accuracy of the new test was determined by comparing operator assessments with inertial sensor data. Paired t-tests were used to compare pelvic movement between the new test and the modified Ober test, with statistical significance set at p \< 0.05.
By addressing the limitations of the modified Ober test, this study seeks to introduce a more precise and clinically applicable method for assessing ITB extensibility.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
OTHER
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Healthy adults
Manual and instrumental evaluation of hip adduction
Manual and instrumental evaluation of hip adduction
The intervention consists of a new manual test for assessing iliotibial band (ITB) tension and hip abductor extensibility. The patient lies supine on the edge of a treatment table with the non-tested leg flexed at the hip and knee, stabilizing the pelvis. The tested leg remains extended. The examiner stabilizes the non-tested leg with one hand and adducts the tested leg until a resistance is felt, ensuring no pain. The hip adduction angle is visually assessed and recorded. A subset of participants also undergoes the modified Ober test for comparison. Inertial motion sensors are used to validate the accuracy of visual assessments. The primary outcomes include intra-rater and inter-rater reliability, while secondary outcomes evaluate the test's accuracy and pelvic movement reduction.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Manual and instrumental evaluation of hip adduction
The intervention consists of a new manual test for assessing iliotibial band (ITB) tension and hip abductor extensibility. The patient lies supine on the edge of a treatment table with the non-tested leg flexed at the hip and knee, stabilizing the pelvis. The tested leg remains extended. The examiner stabilizes the non-tested leg with one hand and adducts the tested leg until a resistance is felt, ensuring no pain. The hip adduction angle is visually assessed and recorded. A subset of participants also undergoes the modified Ober test for comparison. Inertial motion sensors are used to validate the accuracy of visual assessments. The primary outcomes include intra-rater and inter-rater reliability, while secondary outcomes evaluate the test's accuracy and pelvic movement reduction.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
Exclusion Criteria
18 Years
30 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Manusapiens
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Spine Center
Bologna, Bologna, Italy
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
2MOT
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.