Clinical Investigation for Everolimus Drug Eluting Stent

NCT ID: NCT06769217

Last Updated: 2025-01-10

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

ACTIVE_NOT_RECRUITING

Clinical Phase

PHASE4

Total Enrollment

888 participants

Study Classification

INTERVENTIONAL

Study Start Date

2023-01-01

Study Completion Date

2025-11-01

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

History of Device Development and Study Rationale:

Drug-eluting stents (DES) revolutionized percutaneous coronary intervention (PCI) by significantly reducing restenosis and the need for repeat procedures compared to bare-metal stents (BMS). Introduced in the early 2000s, DES quickly became the standard of care due to its superior antiproliferative properties.

DES consist of a metal stent, an antiproliferative drug, and a polymer coating. The stent provides structural support while the drug is gradually released to inhibit tissue growth within the artery. This dual action effectively prevents restenosis, a common complication after PCI.

Contemporary guidelines strongly recommend DES over BMS for various clinical scenarios. The proven efficacy and safety of current-generation DES make them the preferred treatment option for patients undergoing PCI.

First-generation drug-eluting stents:

First-generation drug-eluting stents (DES) marked a significant advancement in interventional cardiology, addressing the persistent issue of in-stent restenosis (ISR) associated with bare-metal stents (BMS). These innovative devices, composed of a metal frame, an antiproliferative drug (sirolimus or paclitaxel), and a polymer coating, were designed to release the drug gradually, preventing tissue growth within the artery. Clinical trials demonstrated the superior efficacy of DES over BMS in reducing ISR and target lesion revascularization (TLR). The RAVEL trial, for example, found a dramatic decrease in ISR with sirolimus-eluting stents (SES). Subsequent studies and meta-analyses confirmed the benefits of both SES and paclitaxel-eluting stents (PES) compared to BMS, particularly in high-risk patients.

The introduction of DES represented a paradigm shift in interventional cardiology, offering a more effective and durable solution for patients with coronary artery disease.

Second-generation drug-eluting stents:

Second-generation drug-eluting stents (DES) were developed to address the safety concerns associated with first-generation DES, such as stent thrombosis (ST), incomplete endothelialisation, and polymer-induced inflammation. These newer stents incorporate less toxic drugs, more biocompatible coatings, and thinner, more flexible struts. Clinical trials have demonstrated the superior safety and efficacy of second-generation DES compared to their predecessors. Studies comparing everolimus-eluting stents (EES) and zotarolimus-eluting stents (ZES) to first-generation DES have shown significant reductions in ST, myocardial infarction (MI), and target lesion revascularisation (TLR). Head-to-head comparisons of EES and ZES have also revealed comparable outcomes in real-world patient populations. Both stents are effective and safe for the treatment of obstructive coronary artery disease, making them the preferred choice for percutaneous coronary intervention.

Study Rationale:

The introduction of drug-eluting stents (DES) marked a significant leap in interventional cardiology by addressing the limitations of bare-metal stents (BMS), primarily through reducing restenosis and the need for repeat procedures. First-generation DES, equipped with antiproliferative drugs like sirolimus and paclitaxel, demonstrated superior efficacy in preventing in-stent restenosis. However, safety concerns, including stent thrombosis and polymer-induced inflammation, led to the development of second-generation DES, which utilises more biocompatible materials and refined designs. Clinical trials have consistently shown that these newer DES offer enhanced safety and effectiveness, solidifying their position as the preferred treatment option in percutaneous coronary interventions.

Study Objectives

The main objective of this study is to assess the safety and effectiveness of the EvroSure Everolimus Drug eluting CoCr stent in obstructive coronary artery disease.

Primary Objective

The primary endpoint of this study is to monitor Major Adverse Cardiac Events (MACE) at 30 days.

Secondary Objective

The following secondary effectiveness endpoints are as follows:

* Angiographic/device success (%)
* Procedural success (%)
* Clinically justified Target Lesion Revascularization (TLR) (%) at 12 months

The following secondary safety endpoints are:

* MACE (%) until 12 months (Clinically Justified)
* Device-related SAEs until 12 months (Clinically Justified)

Note: MACE rate is defined as the incidence of the combined clinical endpoint: Composite of Death (Cardiac death as well as Non-Cardiac), Myocardial Infarction (Q-wave and non-Q-wave), Emergency Coronary Artery Bypass Graft Surgery, clinically justified TLR following index procedure.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

10\. Study Objectives The main objective of this study is to assess the safety and effectiveness of the EvroSure Everolimus Drug eluting CoCr stent in obstructive coronary artery disease.

Primary Objective The primary endpoint of this study is to monitor Major Adverse Cardiac Events (MACE) at 30 days.

Secondary Objective

The following secondary effectiveness endpoints are as follows:

* Angiographic/device success (%)
* Procedural success (%)
* Clinically justified Target Lesion Revascularization (TLR) (%) at 12 months

The following secondary safety endpoints are:

* MACE (%) until 12 months (Clinically Justified)
* Device-related SAEs until 12 months (Clinically Justified) Note: MACE rate is defined as the incidence of the combined clinical endpoint: Composite of Death (Cardiac death as well as Non-Cardiac), Myocardial Infarction (Q-wave and non-Q-wave), Emergency Coronary Artery Bypass Graft Surgery, clinically justified TLR following index procedure.

Study Endpoints

Primary endpoints

The primary endpoint of the study is defined as Major Adverse Cardiac Events (MACE) at 30 days.

Note: MACE rate is defined as the incidence of the combined clinical endpoint: Composite of Death (Cardiac death as well as Non-Cardiac), Myocardial Infarction (Q-wave and non-Q-wave), Emergency Coronary Artery Bypass Graft Surgery, clinically justified TLR within 30 days following index procedure.

Secondary endpoints

The secondary effectiveness endpoints were as follows:

* Angiographic/device success (%) (Angiographic device success is determined by confirming the accurate placement of the device within the targeted coronary arteries through X-ray examination.)
* Procedural success (%) (Procedural success is determined by successful implantation of the stent and clearance of blockage.)
* Clinically justified Target Lesion Revascularization (TLR) (%) at 12 months

The following secondary safety endpoints were assessed:

* MACE (%) until 12 months (Clinically Justified)
* Device-related SAEs until 12 months (Clinically Justified)

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Coronary Arterial Disease (CAD)

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Single Arm

Its a single arm multicenter registry to investigate safety and efficacy of product by clinical follow up at one month and 12 month

Group Type OTHER

Drug Eluting Coronary Stent

Intervention Type DEVICE

The Drug Eluting Coronary stent is indicated for the treatment of de novo coronary artery lesions in patients with symptomatic ischemic heart disease.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Drug Eluting Coronary Stent

The Drug Eluting Coronary stent is indicated for the treatment of de novo coronary artery lesions in patients with symptomatic ischemic heart disease.

Intervention Type DEVICE

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

-1. The patient must be ≥ 18 years of age; 2. Patient was an acceptable candidate for PTCA, Stenting, or Emergent CABG; 3. Patient has clinical evidence of ischemic heart disease or a positive functional study 4. Patient and his or her treating physician agree that the patient will comply with all the required post-procedure follow-up.

5\. Target lesion(s) present with ≥50% stenosis, in one or more vessels 6. Target lesions have to be de novo; 7. One or more target lesions require treatment 8. Reference vessel diameter of target lesion(s) must be ≥ 2.25mm and ≤ 4.5mm, by visual estimate

Exclusion Criteria

* 1\. Previous PTCA with any stent 2. History of CVA or TIA within the last 3 months 3. Patient has active infection 4. Concurrent medical condition with a life expectancy of less than 12 months 5. Clinically relevant contraindication to aspirin, heparin, clopidogrel bisulphate, or ticlopidine including thrombocytopenia, neutropenia, or leukopenia 6. Active peptic ulcer or upper gastrointestinal bleeding. 7. Current participation in an investigational drug or device trial that has not completed its primary endpoint follow-up period.

8\. Pregnancy or woman of childbearing potential who, in the opinion of the investigator, does not take adequate measures to prevent conception.

9\. Known hypersensitivity or contraindication to cobalt, chromium, or nickel
Minimum Eligible Age

18 Years

Maximum Eligible Age

100 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Frisch Medical Device Private Limited

INDUSTRY

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Bhavin Oza, Bsc

Role: STUDY_CHAIR

Frisch Medical Devices

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Baroda Heart Institute & Research Centre

Vadodara, Gujarat, India

Site Status

Grandmed Lubuk Pakam Hospita

Tanjung Morawa, North Sumatra, Indonesia

Site Status

Primaya Tangerang

Jakarta, , Indonesia

Site Status

Countries

Review the countries where the study has at least one active or historical site.

India Indonesia

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

ESC/FM/030622

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.