Comparison Between CAD/CAM and Conventional Mandibular Fixed Retainers.

NCT ID: NCT06529601

Last Updated: 2024-07-31

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

NOT_YET_RECRUITING

Clinical Phase

NA

Total Enrollment

54 participants

Study Classification

INTERVENTIONAL

Study Start Date

2024-09-01

Study Completion Date

2027-09-01

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The devices compared in this study are 'retainers', i.e. fixed orthodontic retainers applied to the lingual surface of the central and lateral incisors and lower canines bilaterally. Their function is to maintain dental alignment once fixed orthodontic therapy has ended. In particular, the CAD/CAM device Keeppy patented by the company Leone SpA (Via Ponte a Quaracchi 50, Sesto Fiorentino, Florence) will be compared with the standard retainer made from a steel braided wire (Ortho FlexTech, Reliance Orthodontic Products Inc., 1540 West Thorndale Ave, Itasca, Illinois, USA).

This is a single-center, national, controlled, superiority, randomized, crossover, open-label study.

The aim of this study is to evaluate whether the CAD/CAM retainer results in fewer failures (fractures or detachments) over a period of 6 months and 2 years compared to the standard retainer. In addition, the aim of the study is to evaluate whether the Keeppy device results in the maintenance of better periodontal health as judged by the use of plaque and bleeding indices on the surfaces of the lower six anterior teeth compared to the standard retainer. Other objectives consist of the patient's assessment of pain, difficulty in speaking and esthetic satisfaction and the stability of the lower anterior tooth sector.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Orthodontic Retainers

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

PARALLEL

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

CAD/CAM mandibular fixed retainer

Group Type EXPERIMENTAL

CAD/CAM mandibular fixed retainer

Intervention Type DEVICE

Keeppy is a Class IIa custom-made medical device manufactured by Digital Service Leone s.r.l. - via Pratese 160/b, Florence, Italy. The Keeppy is an individualized fixed retainer, made of a Nickel-free Chrome Cobalt alloy, produced with a CAD-CAM procedure starting from a digital impression made with an intraoral optical scanner (3 Shape), which allows a perfect adaptation to the lingual surfaces of the 6 lower anterior teeth on which it is bonded. The device is characterized by the presence of applicators that can be placed temporarily on the buccal surface of the canines, which facilitate the clinician in the precise application of the device and which are removed as soon as the bonding phase of the retainer is complete. Bonding is performed using classic composite resins following a preparation phase of the lingual surface of the tooth consisting of the application of etchant (37% orthophosphoric acid) for 30 seconds and adhesive (primer-bonding).

Conventional mandibular fixed retainer

Group Type ACTIVE_COMPARATOR

Conventional mandibular fixed retainer

Intervention Type DEVICE

The standard control device, which is among the most commonly used in routine clinical practice, consists of a steel braided wire. The device selected for the Class IIa investigation is the Ortho Flex Tech manufactured by Reliance Orthodontic Products, Inc. 1540 West Thorndale Ave. Itasca, IL 60143 USA. The Ortho Flex Tech steel braided wire is manually shaped by the clinician and cut with a wire cutter so that it has the proper length to extend over the 6 dental elements. Once the correct length has been defined, it is then held in place on the lingual surface of the teeth by the use of 2 interdental wires passing doubly through the interdental area (between the lateral incisor and canine on one side and the other). This allows the device to be bonded using composite resin after etching the lingual surfaces of the lower anterior teeth.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

CAD/CAM mandibular fixed retainer

Keeppy is a Class IIa custom-made medical device manufactured by Digital Service Leone s.r.l. - via Pratese 160/b, Florence, Italy. The Keeppy is an individualized fixed retainer, made of a Nickel-free Chrome Cobalt alloy, produced with a CAD-CAM procedure starting from a digital impression made with an intraoral optical scanner (3 Shape), which allows a perfect adaptation to the lingual surfaces of the 6 lower anterior teeth on which it is bonded. The device is characterized by the presence of applicators that can be placed temporarily on the buccal surface of the canines, which facilitate the clinician in the precise application of the device and which are removed as soon as the bonding phase of the retainer is complete. Bonding is performed using classic composite resins following a preparation phase of the lingual surface of the tooth consisting of the application of etchant (37% orthophosphoric acid) for 30 seconds and adhesive (primer-bonding).

Intervention Type DEVICE

Conventional mandibular fixed retainer

The standard control device, which is among the most commonly used in routine clinical practice, consists of a steel braided wire. The device selected for the Class IIa investigation is the Ortho Flex Tech manufactured by Reliance Orthodontic Products, Inc. 1540 West Thorndale Ave. Itasca, IL 60143 USA. The Ortho Flex Tech steel braided wire is manually shaped by the clinician and cut with a wire cutter so that it has the proper length to extend over the 6 dental elements. Once the correct length has been defined, it is then held in place on the lingual surface of the teeth by the use of 2 interdental wires passing doubly through the interdental area (between the lateral incisor and canine on one side and the other). This allows the device to be bonded using composite resin after etching the lingual surfaces of the lower anterior teeth.

Intervention Type DEVICE

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

Keeppy

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Patients who have completed fixed orthodontic therapy between the ages of 13 and 20 years;
* Patients whose parents will sign the informed consent

Exclusion Criteria

* Presence of dental anomalies in number (excess or deficiency) in the lower anterior teeth
* Patients with metal allergies.
Minimum Eligible Age

13 Years

Maximum Eligible Age

20 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Azienda Ospedaliero-Universitaria Careggi

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

LF15

Identifier Type: -

Identifier Source: org_study_id

More Related Trials