Cystometry Using a Novel Microsensor System in Patients With Neurogenic Bladder Dysfunction

NCT ID: NCT06445426

Last Updated: 2024-06-14

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

COMPLETED

Total Enrollment

33 participants

Study Classification

OBSERVATIONAL

Study Start Date

2022-06-01

Study Completion Date

2023-12-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

The aim of this study is to assess the feasibility and safety of a novel system for percutaneous measurement of bladder pressure. This system enables minimally invasive procedures and high-quality recordings, offering a sampling rate and synchronization surpassing traditional methods. The pressure sensor system has the potential to be developed into a low-cost method suitable for mass production. The study will include a sample of convenience of up to 40 subjects. Pressure will be recorded simultaneously in the bladder using both the conventional and novel pressure recording systems. This simultaneous recording method will provide a direct comparison of pressure recordings between the two systems. Subjects will be examined for any subjective or objective adverse events.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

The aim of this study is to assess the feasibility and safety of a novel system for measurement of bladder pressure. The system facilitates a minimally invasive procedure, enabling high-quality recordings with a sampling rate and synchronization that surpass conventional standards. The pressure sensor system has potential to be developed into a low-cost method with mass production. In patients with spinal cord injury and neurogenic bladder dysfunction, measurement of pressure in the bladder (cystometry) is mandatory to evaluate risk factors and assess treatment options. This novel system consists of a micro electro mechanical system (MEMS) integrated in a hollow flexible tube made out of biocompatible material. Recording from this sensor catheter is transmitted to specialized electronic and digital devices for processing. Due to a sensor catheter with a diameter less than 1.0 mm, it is possible to perform transurethral cystometry using a simple minimally invasive technique. The study goal is to compare the simultaneous measurement of the conventional water perfused system compared to a novel pressure sensor system during cystometry. produce high-quality recordings with a higher than conventional sampling rate. The study will include a sample of convenience of up to 40 subjects. The pressure will be recorded simultaneously with the conventional and novel pressure recording system in the urinary bladder. The simultaneous recording with the novel and the conventional method will provide a direct comparison of simultaneous recording of pressure between the two systems. Patients will be examined for subjective or objective adverse events. The sample size is too small for comparison of validity of the two methods in clinical practice. However, the study should be able to conclude on reliability. Thus, pressure measurements will be assessed with both methods during cystometry in up to 40 subjects. Given the technical specifications, the measurements are expected to be nearly identical, thereby ensuring reliability. The study is not intended to provide conclusive results on the comparison between conventional water perfused recording and the novel MEMS pressure system. However, results from this initial study will be the basis for further studies with sufficient power to validate conventional versus novel MEMS technique.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Spinal Cord Injuries Urinary Bladder, Neurogenic

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Observational Model Type

CASE_ONLY

Study Time Perspective

PROSPECTIVE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Simulataneous bladder pressure recording

In all patients recruited, the pressure will be recorded simultaneously with the conventional and novel pressure recording systems in the bladder. The procedure will be done according to the International Continence Society's (ICS) recommended indications for the procedure.

Cystometry

Intervention Type DEVICE

The procedure will be done according to the International Continence Society's (ICS) recommended indications for the procedure. The investigational device is inserted into a 12F single-use hydrophilic catheter. After correct positioning is verified by ultrasound and x-ray, the investigational device is released from the insertion catheter. The insertion catheter is then carefully removed, securing the correct positioning of the investigational device inside the bladder. The investigational device is connected to a data logger. In the conventional device, the intravesical pressure is recorded using a water perfused 3F catheter with a 3 ml/hour perfusion rate. The 3F catheter is hooked on an 8F catheter to facilitate introduction into the bladder. The catheters used for pressure transmission are connected to external transducers and a computer with software processing the recording

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Cystometry

The procedure will be done according to the International Continence Society's (ICS) recommended indications for the procedure. The investigational device is inserted into a 12F single-use hydrophilic catheter. After correct positioning is verified by ultrasound and x-ray, the investigational device is released from the insertion catheter. The insertion catheter is then carefully removed, securing the correct positioning of the investigational device inside the bladder. The investigational device is connected to a data logger. In the conventional device, the intravesical pressure is recorded using a water perfused 3F catheter with a 3 ml/hour perfusion rate. The 3F catheter is hooked on an 8F catheter to facilitate introduction into the bladder. The catheters used for pressure transmission are connected to external transducers and a computer with software processing the recording

Intervention Type DEVICE

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

Pressure measurement in the urinary bladder

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Documented traumatic or non-traumatic spinal cord injury
* Documented neurogenic bladder dysfunction by previous cystometry
* More than 3 months after injury
* Subject is able to communicate in Norwegian
* Subject is able and willing to sign informed consent
* Subject is able to complete all study requirements

Exclusion Criteria

* History or evidence of previous urological or lower abdominal abnormalities from disease or surgery
* Use of anti-platelet or anti-coagulant other than low molecular weight heparin or acetylsalicylic acid which cannot be discontinued
* Symptomatic urinary tract infection
* Hemophilia or other clotting disorders that cause bleeding diathesis
* Any condition or situation, which, in the investigator's opinion, puts the subject at significant risk, could confound the study results, or may interfere significantly with the subject's participation in the study
Minimum Eligible Age

18 Years

Maximum Eligible Age

80 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

SINTEF MiNaLab

UNKNOWN

Sponsor Role collaborator

University of Oslo

OTHER

Sponsor Role collaborator

Sunnaas Rehabilitation Hospital

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Thomas Glott

Medical director

Responsibility Role PRINCIPAL_INVESTIGATOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Sunnaas Rehabilitation Hospital

Oslo, Nesoddtangen, Norway

Site Status

Countries

Review the countries where the study has at least one active or historical site.

Norway

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

SUPRE

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Urodynamics: Prone Vs. Seated Position
NCT06864117 NOT_YET_RECRUITING NA