Bone Bioactive Liquid Efficiency in Improving Dental Implant Osteointegration Oral Soft Tissue Hellingand Oral Surgery
NCT ID: NCT06371430
Last Updated: 2024-06-04
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
33 participants
INTERVENTIONAL
2021-04-14
2024-04-14
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Osteoimplant and Bone Healing
NCT06664060
Impact of Buccal Bone Thickness on Pathological Peri-implant Bone Loss: A 3-year Prospective Cohort Study
NCT02939222
Radiographic and Clinical Evaluation In Bar
NCT06401200
Comparative Study of Implant Surfaces to Enhance Stabilization in Patients With Type 2 Diabetes
NCT01142297
Analysising the Marginal Bone Loss, Torque and Implant Stability Placed in Bone and Tissue Level Dental Implants
NCT07288606
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Methods Investigators implanted 264 Galaxy TS implants (with or without BBL) in 33 patients across both jaws. Implant stability and osseointegration were assessed using Initial Stability Quotient (ISQ) measurements, computed tomography (CBCT) scans and pain evaluations at various intervals post-surgery. Further, implant surfaces were examined using scanning electron microscopy (SEM) and atomic force microscopy (AFM). In vitro studies evaluated the efficacy of BBL on dental pulp pluripotent stem cells (DPPSCs) osteogenesis, and inflammatory factor modulation in human macrophages.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
FACTORIAL
TREATMENT
QUADRUPLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Pain Scale
To assess the efficacy of the surgical procedure, pain scale evaluations were conducted on day 1,4 and 7, following the surgery. This evaluation involved a direct contact with the patients to gauge their subjective pain experience. A modified visual analog scale (VAS) was utilized, as described in reference \[34\]. No pain scale = 0, moderate pain scale = 5 and maximum pain scale = 10 \[21\]. In addition to efficacy measurements, safety measurements were also considered. The occurrence of adverse events (AEs) and serious adverse events (SAEs) was monitored throughout the duration of the study. These events were either detected by the investigator or reported by the patients themselves. The aim was to identify any potential complications or issues that arose because of the surgical procedure.
Dental Implant insertion and tooth extraction
The osteotomies were carried out at a speed of 800 rpm, using sequential burs of similar diameter for both the maxilar and the mandibular side. The drilling protocols followed the recommendations provided by the manufacturer, the Galaxy-Ziacom implant system, for standard drilling.
The insertion of the implants was initiated using a motor handpiece at a speed of 20-50 rpm, without irrigation. The installation process was completed using a manual surgical torque wrench indicator. The maximum torque value (Ncm) reached at the end of implant insertion was recorded as the insertion torque (IT). A total of 264 implants were inserted in 33 patients, 160 implants were post-extraction and 104 implants were inserted after at least one-month post-extraction. The sutures were typically removed 1 week after the surgery, during the postoperative follow-up appointment.
RFA and ISQ measurements
After the implants were fully seated, a Smartpeg specific to the implant system and restorative platform diameter was used for each implant. RFA was then performed using an OsstellMentor device from Ostell/Integration Diagnostics in Gothenburg, Sweden. This analysis was used to measure the ISQ values for all implant surfaces at days 0, 7 and 30 post-surgeries. For each implant, 4 readings were taken per lingual, mesial, distal, and vestibular direction. The average ISQ values of all the readings were recorded. Following the RFA measurements, new sterile healing abutments were inserted, and the incisions were sutured to close the wounds.
Dental Implant insertion and tooth extraction
The osteotomies were carried out at a speed of 800 rpm, using sequential burs of similar diameter for both the maxilar and the mandibular side. The drilling protocols followed the recommendations provided by the manufacturer, the Galaxy-Ziacom implant system, for standard drilling.
The insertion of the implants was initiated using a motor handpiece at a speed of 20-50 rpm, without irrigation. The installation process was completed using a manual surgical torque wrench indicator. The maximum torque value (Ncm) reached at the end of implant insertion was recorded as the insertion torque (IT). A total of 264 implants were inserted in 33 patients, 160 implants were post-extraction and 104 implants were inserted after at least one-month post-extraction. The sutures were typically removed 1 week after the surgery, during the postoperative follow-up appointment.
CBCT analysis
CBCTs were captured for implants from six patients with total of 24 implants, with 12 implants Galaxy TS (non-treated) on one side of the jaw and 12 implants Galaxy TSA (treated with BBL) on the other side of the jaw. All patients in this group had implants inserted in the upper jaw and each patient had 4 implants inserted (All on 4 technique). The CBCTs scans were conducted at days 1 and 60 post-surgeries using a 3D Accuitomo 170 scanner (J. MORITA EUROPE GMBH). The scans were performed with the following technical parameters: 90 kV, 5 mA, 87.5 mAs, voxel size ranging from 125-250 µm, 360° rotation, and scanning time of 17.5 s as previously described \[32\]. To ensure accuracy, a bite mark was utilized during CBCT scanning to correspond to the patients' midline. Consistency in bite mark placement was maintained to ensure that the same slice was obtained for each scan performed on the patient
Dental Implant insertion and tooth extraction
The osteotomies were carried out at a speed of 800 rpm, using sequential burs of similar diameter for both the maxilar and the mandibular side. The drilling protocols followed the recommendations provided by the manufacturer, the Galaxy-Ziacom implant system, for standard drilling.
The insertion of the implants was initiated using a motor handpiece at a speed of 20-50 rpm, without irrigation. The installation process was completed using a manual surgical torque wrench indicator. The maximum torque value (Ncm) reached at the end of implant insertion was recorded as the insertion torque (IT). A total of 264 implants were inserted in 33 patients, 160 implants were post-extraction and 104 implants were inserted after at least one-month post-extraction. The sutures were typically removed 1 week after the surgery, during the postoperative follow-up appointment.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Dental Implant insertion and tooth extraction
The osteotomies were carried out at a speed of 800 rpm, using sequential burs of similar diameter for both the maxilar and the mandibular side. The drilling protocols followed the recommendations provided by the manufacturer, the Galaxy-Ziacom implant system, for standard drilling.
The insertion of the implants was initiated using a motor handpiece at a speed of 20-50 rpm, without irrigation. The installation process was completed using a manual surgical torque wrench indicator. The maximum torque value (Ncm) reached at the end of implant insertion was recorded as the insertion torque (IT). A total of 264 implants were inserted in 33 patients, 160 implants were post-extraction and 104 implants were inserted after at least one-month post-extraction. The sutures were typically removed 1 week after the surgery, during the postoperative follow-up appointment.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* sufficient residual bone volume to accommodate implant placement without requiring bone augmentation, minimum ridge height and width of ≥ 9mm and ≥ 6mm, respectively, and healed bone sites with a minimum of 1 months of post-extraction healing.
Exclusion Criteria
* Smoking habits.
* History of illicit drug use were excluded.
* Patients with heart diseases.
* Diabetes.
* Previous bone regenerative or augmentation procedures.
* Bleeding disorders.
* Compromised immune systems.
* History of radiation therapy
* Treatment with steroids or bisphosphonates
18 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Universidad Pública de Navarra
OTHER
Dasman Diabetes Institute
OTHER
Biointelligent Technology Systems SL
INDUSTRY
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Maher Atari Abouasi
Director
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Biointelligent Technology Syst
Barcelona, , Spain
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
Biointelligent Technology Syst
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.