Non-Carious Cervical Lesions Restorations Using Different Modes of Universal Adhesive
NCT ID: NCT06227715
Last Updated: 2024-01-29
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
25 participants
INTERVENTIONAL
2016-04-28
2023-11-28
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Material and methods: SBU Adhesive was applied in 252 NCCLs of 25 patients using different modes adhesion approaches: Self-etch (SE), selective-enamel-etching (SLE), total-etch (TE). All lesions were restored with nanohybrid resin composite. Restorations were evaluated at baseline, 6th, 12th, 18th, and 36th month using the FDI criteria. IBM SPSS Statistics for Windows, Version 24.0. program was used in the analysis. Differences between SE, SLE and TE groups were tested using Kruskal Wallis test. A value of p\<0.05 was accepted as a criterion for statistical significance.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Laser Etching Effect on Application Mode of Universal Adhesive
NCT04814836
Evaluation of the Reduced Dentin Etching Time Using Universal Adhesives in the Quality of Cervical Lesions Restorations
NCT06465849
Clinical Performance of a One-step Self-etch Adhesive in Non-carious Cervical Lesions at 2 Years
NCT04565938
Clinical Evaluation of Three Different Universal Adhesives in Non-carious Cervical Lesions
NCT03415412
Clinical Comparison of Universal Adhesives in Terms of Different Application Modes on the Restoration of NCCLs
NCT03415516
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Sample Size Calculation G\* Power statistical software was used to calculate the sample size. For an effect size (Cohen 'D Effect Size) difference of 0.30 between the groups with 99% power, DF=2 and an alpha error of 5%, at least 238 restorations were needed.
Patient Selection Adults who achieved the inclusion/exclusion criteria and required restoration of at least one notch shaped NCCL were included in the study. Inclusion criteria were the presence of at least 20 teeth and 6 NCCL, the absence of common caries, and the use of universal adhesive and nanohybrid resin composite. Candidates with poor oral hygiene, acute or chronic periodontal disease, xerostomia, and malocclusion were excluded.
The patient forms, in which the identity information of the patients participating in the study and the size of the lesion in the restored teeth, the type and mode of adhesive used in the restoration, and the restorative material were recorded, were reviewed and the necessary tooth groupings were made following the recorded data.
Application Procedure of Restorations The NCCL dimensions in millimeters (height and width) were determined with a digital caliper. Prior to the restoration procedures, a pumice stone and water were used for prophylactic purposes, then the dentin was abraded and beveled to the enamel surface (1-2 mm). Before the restoration of the lesions, isolation was achieved with the use of retraction cord (Ultrapak, Ultradent Products, USA) and cotton rolls. Three different application modes of the universal dentin bonding (Single Bond Universal, 3M ESPE, Germany) adhesive were applied in the restoration of the teeth (table 2). These are TE, in which both dentin and enamel are etched, SLE, in which only enamel is etched, and SE, in which only the adhesive is applied. Each mode of the universal adhesive used in the mouth of each of the patients evaluated was applied to at least two teeth. In accordance with the recommendations of the manufacturer; in TE mode, enamel and dentin were etched with 37% orthophosphoric acid for 15 seconds, washed for 15 seconds, and after air-drying, the adhesive was applied to enamel and dentin by rubbing for 20 seconds. In SLE mode, only enamel margin was etched for 15 seconds, washed for 15 seconds and dried, and the adhesive was applied to the dentin and enamel by rubbing for 20 seconds. In SE mode, the adhesive was applied to the dentin and enamel by rubbing for 20 seconds. After the adhesive was applied in all modes, it was dried for 5 seconds gently and polymerized 10 seconds using a curing light (SmartLite Focus, Dentsply Sirona, USA). Afterwards, all of them were restored with the same nanohybrid resin composite (Filtek Z550, 3M ESPE, USA) in accordance with the layering technique. Restorations were completed by polishing under water cooling with fine diamond burs (GZ Instrumente, Austria) and polishing discs (Soflex Finishing and Polishing Disc, 3M ESPE, USA).
Assessment of Restorations At the 1st, 6th, 12th, 18th, and 36th month, the restorations were evaluated based on the FDI criteria and the results were recorded on the clinical research follow-up form. Two calibrated experienced dentists evaluated the restorations without knowing which adhesive technique was used on which patient, except for the treating dentist, using a mirror and sond under reflector light.
Restorations were evaluated marginal staining, fracture of material and retention, marginal adaptation, post-operative sensitivity and vitality, recurrence of caries, erosion and abfraction, tooth integrity according to the FDI criteria. According to the FDI criteria, these variables were ranked as follows: clinically very good (1), clinically good (2), clinically satisfactory (3), clinically unsatisfactory (4), and clinically poor (5). In accordance with these criteria, values of 1,2 and 3 are clinically acceptable, while 4 and 5 are considered clinically not acceptable.16 The difference between the adhesive modes and the time-dependent variation within each mode were evaluated. Among the evaluated restorations, those with retention loss were evaluated only according to the retention loss criteria and scored with 5 and were not evaluated in terms of other criteria. Restorations that were unsuccessful due to either loss of retention or irreparable secondary caries were replaced with new composite resin restorations. These new restorations were then excluded from the study for further evaluation.
Statistical Analysis Descriptive statistics were used to present the frequency distributions. Shapiro Wilk's test was performed to evaluate the normality of data distribution and it was seen that data were not normally distributed. Differences between SE, SLE and TE groups were tested using Kruskal Wallis test. The was used to compare the groups at baseline, 6, 12, 18 and 36 months. To compare the data in marginal staining, fracture of material and retention, marginal adaptation, post-operative sensitivity and vitality, recurrence of caries, erosion and abfraction, tooth integrity within each group by time, further analyses were carried out using the K Releated Samples and Wilcoxon tests. IBM SPSS Statistics for Windows, Version 24.0. (Armonk, NY: IBM Corp., USA) program was used in the analysis. A value of p\<0.05 was accepted as a criterion for statistical significance.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NON_RANDOMIZED
PARALLEL
TREATMENT
SINGLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
selective etch
In SLE mode, only enamel margin was etched for 15 seconds, washed for 15 seconds and dried, and the adhesive was applied to the dentin and enamel by rubbing for 20 seconds.
universal adhesive
Total etch
Each mode of the universal adhesive used in the mouth of each of the patients evaluated was applied to at least two teeth. In accordance with the recommendations of the manufacturer; in TE mode, enamel and dentin were etched with 37% orthophosphoric acid for 15 seconds, washed for 15 seconds, and after air-drying, the adhesive was applied to enamel and dentin by rubbing for 20 seconds.
universal adhesive
self etch
In SE mode, the adhesive was applied to the dentin and enamel by rubbing for 20 seconds.
universal adhesive
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
universal adhesive
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* The absence of common caries
* The use of universal adhesive and nanohybrid resin composite
Exclusion Criteria
* Acute or chronic periodontal disease
* Xerostomia,
* Malocclusion were excluded.
20 Years
80 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Eskisehir Osmangazi University
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Hatice Tepe
Lecturer
References
Explore related publications, articles, or registry entries linked to this study.
Tepe H, Celiksoz O, Yaman BC. Clinical evaluation of single bond universal adhesive in non-carious cervical lesions: a 36-month retrospective study. Clin Oral Investig. 2024 Dec 28;29(1):33. doi: 10.1007/s00784-024-06126-y.
Related Links
Access external resources that provide additional context or updates about the study.
FDI Criteria for dental restorations
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
80558721/G-109
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.