Evaluation of Digital Versus Conventional Techniques for Construction of Mandibular Implant Retained Overdenture
NCT ID: NCT06139003
Last Updated: 2023-11-18
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
20 participants
INTERVENTIONAL
2022-08-20
2023-08-20
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
1\. Digital occlusion stability detection: evaluated by using OccluSense.
Evaluation was done in the following evaluation period:
T0: Immediately after over denture insertion. T6: 6 months after over denture insertion. T12: 12 months after over denture insertion.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Impact of Mandibular Overdenture Base Construction Techniques on Assessment of Occlusion
NCT06080815
Effect of Two Different Digital Construction Techniques of Implant-assisted Overdentures
NCT06720389
Effect of Implant Position on Clinical Outcomes
NCT06166316
Digital Workflow Versus Functional Pick-up Techniques of Two- Implant Retained Mandibular Overdentures
NCT06995547
3D-Printed Implant Overdentures: Comparing Impression Techniques
NCT07208812
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Six patients who required complete denture were selected from the diagnostic clinic of Prosthodontic Department, Faculty of Dentistry, Mansoura University. All patients were informed about the procedures that was done and a written consent form of ethical committee. All patients had the right to withdraw from the study at any time.
Patients Grouping:
Patients were divided in to 2 equal groups:
Group (I): 3 patients received maxillary CD and mandibular 2-implant retained overdenture constructed by digital technique.
Group (II): 3 patients received maxillary CD and mandibular 2-implant retained overdenture constructed by conventional technique.
Surgical phase procedures:
1. Preoperative investigations of the patient were done that included the blood profile (hemoglobin, complete blood (cell) count, bleeding time, clotting time, random blood sugar).
2. Preoperative assessment of mandibular bone was done radiographically by cone beam computerized tomography (CBCT).
3. Each patient received two dental implants in the canine area bilaterally.
4. All implants were placed according to the flapless protocol.
5. A customized surgical stent fabricated according to the preoperative computer based 3D plan and used during the surgical procedure to ensure accurate implant position and angulation.
6. A small round bur (or Guide drill) the first drill used to make a hole of 1-2 mm deep to create a start point for the pilot drill.
7. The pilot drill is the first twist drill used to create the osteotomy up to the desired length.
8. The drills should be repeatedly pumped in and out of the osteotomy to expose the bone debris to the water coolants for clearing.
9. A guide pin should be placed in the prepared site to check alignment and parallelism.
10. Subsequent drills were used in the same way as the pilot drill to enlarge the osteotomy to the desired depth.
11. Profile drills or countersink drills were used to widen the crestal part of the osteotomy to allow the next drill into the osteotomy and to allow the placement of the cover screw without any bony interference.
12. Osteotomy was performed through the sleeves of the surgical stent and the implants were placed by hand using a torque wrench (35-45 Ncm) through the sleeves. the implant placed 0.5 mm slightly subcrestal, and cover screws were secured using Hex driver.
13. The dentures were molded to not interfere with the peri-implant tissues and reduce occlusal forces on the implant.
After 3 months of osteointegration period, the implants were exposed, the cover screw was removed and the two healing abutments were screwed into the fixture using their driver for 7 to 10 days.
Each patient received maxillary complete denture against mandibular 2- implant retained complete overdenture with two different construction techniques.
The clinical procedures in the respective visits are described below:
Steps of conventional complete overdenture construction:
1. For each patient in group two, preliminary maxillary and mandibular impressions were made using irreversible hydrocolloid impression material and stock impression trays.
2. on custom trays border molding performed by using a thermoplastic compound green sticks.
3. The maxillary definitive impressions were made by using a zinc oxide impression material.
6\. The mandibular definitive impressions were made by direct impression technique with the aid of impression post and laboratory analogue.
7\. Models were poured with implant analogues; the definitive locator attachment was screwed.
8\. Fabrication of maxillary and mandibular record blocks were done and the labial fullness was established, occlusal plane, and occlusal vertical dimension was recorded and the reference lines (midline and canine line) was marked on the wax rims.
9\. Centric jaw relation was registered. Using face bow, upper cast mounted and then centric relation recorded.
10\. Selection of teeth was done by using the readymade artificial acrylic teeth with lingualized occlusal scheme. And setting of teeth was done with bilateral balanced occlusion.
11\. Try-in, processing, finish and polish of the dentures were done.
Digital complete overdenture construction:
1. For each patient in group one, preliminary maxillary and mandibular impressions and poured with dental stone in casts and custom trays were fabricated.
2. Border molding performed. The maxillary and mandibular definitive impressions were made.
3. Models were poured with implant analogues; the definitive locator attachment was screwed.
4. Scanning for the model was done to achieve 3D virtual image to the models.
5. Fabrication of maxillary and mandibular record blocks were done and the labial fullness was established, occlusal plane, and occlusal vertical dimension was recorded and the reference lines (midline and canine line) marked on the wax rims and the resultant data was scanned.
6. The file of this master scan in STL format transmitted to the CADCAM complete denture provider using a purpose-built software program.
7. The anatomic landmarks identified, and the peripheral limits marked on a virtual model in the design software, which then was served to design the definitive denture base.
8. A virtual tooth arrangement was generated for a digital preview.
9. The digital preview was evaluated and modified if necessary.
10. Transfer data to a CAM software program, the prostheses printed, finished and polished.
Insertion the prosthesis into the patient's mouth and have them bit down until the resin has cured. Remove the prostheses and trim the excess resin. The prosthesis delivered and patient instructed about the aftercare and recall schedule steps.
Evaluation
Digital occlusal stability detection:
Group I and group II subjected to test by utilization of the Digital Occlusal Analyzer System (OccluSense). The occlusal forces distribution, extent and time sequence can then have recorded: Immediately, 6 and 12 months after denture use.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
PARALLEL
TREATMENT
SINGLE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
3d Printed implant overdenture
patients will receive maxillary CD and mandibular 2-implant retained overdenture over locator attachment constructed by digital technique.
3d Printed implant
Occlusal stability was evaluated using occlusense device by charting amount and distribution of force over dental arch in percentage
Conventionally constructed implant overdenture
patients will receive maxillary CD and mandibular 2-implant retained overdenture over locator attachment constructed by conventional technique.
Conventionally constructed implant
Occlusal stability was evaluated using occlusense device by charting amount and distribution of force over dental arch in percentage
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
3d Printed implant
Occlusal stability was evaluated using occlusense device by charting amount and distribution of force over dental arch in percentage
Conventionally constructed implant
Occlusal stability was evaluated using occlusense device by charting amount and distribution of force over dental arch in percentage
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Completely edentulous jaws for at least 1 year.
* The angle's class I maxillomandibular relationship and have upper and lower completely edentulous arches.
* Residual alveolar ridges covered with healthy firm mucosa.
* All included patients' sufficient available length and width of mandibular bone to accommodate conventional implant. (At least 5 mm buccolingual width and 12 mm vertical height of bone).
Exclusion Criteria
* metabolic diseases related to bone resorption such as uncontrolled diabetics or osteoporosis will be also excluded
* History of para-functional habits (Bruxism, clenching), smoking and alcoholism.
* History of radiation therapy in the head and neck region.
45 Years
60 Years
MALE
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Mansoura University
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Mohamed shady
principle investigator
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Mohamed Shady, MD
Role: PRINCIPAL_INVESTIGATOR
Mansoura University Faculty of Dentistry, Prosthodontics department
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Mansoura University, Faculty of dentistry
Al Mansurah, , Egypt
Countries
Review the countries where the study has at least one active or historical site.
References
Explore related publications, articles, or registry entries linked to this study.
Ali AEA, Habib A, Shady M. Digital versus conventional techniques for construction of mandibular implant retained overdenture. BMC Oral Health. 2025 May 5;25(1):686. doi: 10.1186/s12903-025-05918-2.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
A02060922
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.