Versatility of a Circular Multielectrode Catheter in the Individualized Recognition & Treatment of Atrial Fibrillation and Related Arrhythmias Using Pulsed Field Energy
NCT ID: NCT06056557
Last Updated: 2025-09-02
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
141 participants
INTERVENTIONAL
2023-09-28
2025-04-18
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Pragmatic Evaluation of a Pentaspline Pulsed Field Ablation System to Treat Atrial Fibrillation and Related Arrhythmias
NCT06765356
Safety and Effectiveness of TactiCath™ Contact Force, Sensor Enabled™ (TactiCath SE) Catheter for Ablation of Drug Refractory, Symptomatic, Persistent Atrial Fibrillation
NCT03650556
Safety and Effectiveness of Pulmonary Vein isOLation And posterioR Wall Ablation wIth pulSed Field Energy in Patients With Paroxysmal and Persistent AF
NCT06099730
Treatment of Focal Ventricular Tachycardias Using a Pulsed Field Ablation From a Point Ablation Catheter Short Title FOCUS-PFA
NCT06747013
A Study Assessing Long-Term Safety and Effectiveness in Treatment Management of Atrial Fibrillation With VARIPULSE Catheter System
NCT07227532
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
In some sense, the incorporation of these restrictive criteria is not terribly surprising since most of the novel PFA catheters are specifically designed to perform only certain aspects of the AF ablation procedure (e.g., just PVI). That is, when there are more complex substrates (where other types of lesion sets may be needed), it may not be practical to allow a more inclusive criteria for enrollment. Of course, the downside is that the majority of the patients that are eventually treated in clinical practice are not reflected by the enrolled patient population.
The VARIPULSE™ catheter technology is a novel circular catheter with a variable loop design, containing multiple electrodes with individual irrigation pores capable of delivering pulse-field energy.
The Ablation procedure will follow the below sequence:
* Anatomical and voltage mapping of the left and/or right atrium
* To perform this mapping, the VARIPULSE bi-directional catheter or a compatible conventional FDA-approved multi-electrode mapping catheter (e.g., Pentaray, Octaray or Optrell) may be used
* Activation mapping of any-presenting or inducible atrial flutter
* Pulmonary Vein Isolation (PVI) to be achieved in all patients with atrial fibrillation (if not already achieved).
* Confirmation of entrance block with adenosine or isoproterenol challenge
* Additional ablation lesion sets are per the investigator's discretion including:
* Posterior wall Isolation
* Regional fractionation clusters
* Cavo-tricuspid isthmus Line
* Mitral Isthmus Line
* Any micro-/macro-reentrant atrial tachycardia's
* As part of the ablation procedure, any safety assessments that are considered important (e.g., EGD, coronary angiography, etc.) may be performed; these data will also be collected.
This study is a prospective, single-center, non-randomized, interventional clinical study to determine the safety and efficacy in using BWI IRE ablation system in a variety of atrial arrhythmias. Subjects will be followed for 12 months post-procedure.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Interventional
All patients will receive the intervention. That is, all patients will undergo ablation with the experimental catheter (device).
VARIPULSE™ catheter ablation
Subjects will arrive to the electrophysiology laboratory for their ablation procedure and will undergo preparation for the procedure per standard protocol.
The purpose of an ablation procedure is to scar or destroy the heart tissue causing the atrial fibrillation. The current FDA approved ablation treatments commonly use freezing, radio frequency, or laser, delivered through a catheter that is threaded through blood vessels to the heart, as the energy source to destroy the abnormal tissue.
The BWI IRE VARIPULSE ablation system used in this study uses a type of energy source called pulse field.
Pulse field ablation applies ultra-rapid (less than 1 second) electrical fields to the heart muscle to destroy the abnormal tissue. This type of energy is thought to safer and more effective at treating atrial fibrillation.
● For a lesion set that cannot be performed using the VARIPULSE catheter technology, a conventional FDA-approved RF ablation
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
VARIPULSE™ catheter ablation
Subjects will arrive to the electrophysiology laboratory for their ablation procedure and will undergo preparation for the procedure per standard protocol.
The purpose of an ablation procedure is to scar or destroy the heart tissue causing the atrial fibrillation. The current FDA approved ablation treatments commonly use freezing, radio frequency, or laser, delivered through a catheter that is threaded through blood vessels to the heart, as the energy source to destroy the abnormal tissue.
The BWI IRE VARIPULSE ablation system used in this study uses a type of energy source called pulse field.
Pulse field ablation applies ultra-rapid (less than 1 second) electrical fields to the heart muscle to destroy the abnormal tissue. This type of energy is thought to safer and more effective at treating atrial fibrillation.
● For a lesion set that cannot be performed using the VARIPULSE catheter technology, a conventional FDA-approved RF ablation
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Diagnosed with atrial fibrillation or atrial atypical atrial flutter (typical flutter may also be ablated provided that the typical flutter occurs in addition to atrial fibrillation or atypical flutter; that is, typical flutter as the sole arrhythmia should not undergo PFA).
* Previous surgical or catheter ablation for atrial fibrillation is allowed
* Planned for a catheter ablation procedure
* Able and willing to provide written consent and comply with all testing and follow-up requirements
* Have in place or are planned to receive an implantable loop recorder, pacemaker or defibrillator capable of recording atrial rhythm
Exclusion Criteria
* Conditions that preclude the introduction and manipulation of intracardiac catheters: eg, active intracardiac thrombus, myxoma, tumor, a prohibitive interatrial baffle or patch, etc.)
* Previous PCI/MI within the past 1 month
* Active systemic infection or sepsis
* Uncontrolled heart failure - New York Heart Association (NYHA) function class IV.
* History of blood clotting, bleeding abnormalities or contraindication to anticoagulation.
* Significant congenital anomaly or medical problem that in the opinion of the investigator would preclude enrollment.
* Women who are pregnant, lactating, or who are of childbearing age and plan on becoming pregnant during this trial.
* Life expectancy or other disease processes likely to limit survival to less than 12 months.
* Currently enrolled in an investigational study evaluating another device, biologic, or drug, that would interfere with this trial.
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Vivek Reddy
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Vivek Reddy
Professor
Principal Investigators
Learn about the lead researchers overseeing the trial and their institutional affiliations.
Vivek Reddy, MD
Role: PRINCIPAL_INVESTIGATOR
Icahn School of Medicine at Mount Sinai
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Icahn School of Medicine at Mount Sinai
New York, New York, United States
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
STUDY-23-00978
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.