Comparison Between the Octaray and Pentaray Catheters in Patients Undergoing Ablation for Atrial Tachycardia.
NCT ID: NCT05765565
Last Updated: 2023-03-13
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
NA
40 participants
INTERVENTIONAL
2023-03-21
2024-03-21
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Participants will be randomized with 1:1 ratio for undergoing 3D anatomy map with either Octaray (intervention group) or Pentaray (control) group. Next, all patients will undergo activation map of the AT with both catheters. For ablation in the intervention group, the Ocatray made activation map of the AT will be used, and the Pentary made AT activation map will be used in the control group.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Randomised Comparison of the Octaray and Pentaray Catheters
NCT05988424
A Study Assessing Arrhythmia Mapping With a Multi-Electrode Mapping Catheter
NCT07116525
Safety and Effectiveness of TactiCath™ Contact Force, Sensor Enabled™ (TactiCath SE) Catheter for Ablation of Drug Refractory, Symptomatic, Persistent Atrial Fibrillation
NCT03650556
Versatility of a Circular Multielectrode Catheter in the Individualized Recognition & Treatment of Atrial Fibrillation and Related Arrhythmias Using Pulsed Field Energy
NCT06056557
The TRAMPOLINE VT Study
NCT05152784
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
The main outcome of the trial is the performance of the Coherent Mapping quality (electrograms per map) with Octaray catheter versus Pentaray catheter for left and right atrium, separately. A map will be considered complete when the fill threshold reach 5 mm for the entire surface area of the left or right atrium, that is the interpolation between points will be \<5 mm as previously reported. The high- and low-pass filters settings will be harmonized between the catheters. The following data will be collected: 1) number of electrograms per map; 2) Voltage based signal-to-noise ratio (vSNR),17 calculated as the ratio between the mean of the peak-to-peak amplitude of the true local bipolar atrial signals and the mean of the SD of the peak-to-peak of all other signals considered as far-field or ambient lab noise; 3) electrograms acquisition rate (i.e., the acquired number of points per minute of mapping); 4) electrograms acquisition density (i.e., the acquired number of electrograms per cm2 of the left or right atrium); 5) number of electrograms acquired per beat; 6) the total ablation and fluoroscopy times; 7) acute mapping success rate, defined as termination of AT at the target region; 8) number of entrainments attempted and the best post-pacing interval value at the ablation site when available. Successful entrainment is sometimes not possible (i.e., focal AT) and some investigator may prefer not to entrain. Therefore, the decision to use entrainment and the number of entrainment attempts will be left to the discretion of the operator.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
RANDOMIZED
CROSSOVER
DIAGNOSTIC
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Octaray (intervention)
Octaray created 3D map quality
Octaray multi-electrode catheter
Newly designed multi-electrode catheter for creating 3D electroanatomical CARTO maps.
Pentaray (control)
Pentaray created 3D map quality
Pentaray multi-electrode catheter
Current standard multi-electrode catheter for creating 3D electroanatomical CARTO maps.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
Octaray multi-electrode catheter
Newly designed multi-electrode catheter for creating 3D electroanatomical CARTO maps.
Pentaray multi-electrode catheter
Current standard multi-electrode catheter for creating 3D electroanatomical CARTO maps.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Planned for catheter ablation of either left- or right-atrium AT/flutter will be eligible for inclusion. In the group of right atrium AT patients with typical flutters will also be eligible for inclusion.
Exclusion Criteria
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Erasmus Medical Center
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Tamas Szili-Torok
Dr.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
MEC-2022-0269
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.