Randomised Comparison of the Octaray and Pentaray Catheters

NCT ID: NCT05988424

Last Updated: 2023-08-14

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

UNKNOWN

Clinical Phase

NA

Total Enrollment

30 participants

Study Classification

INTERVENTIONAL

Study Start Date

2023-09-30

Study Completion Date

2024-09-30

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

In this study we aim to compare the mapping performance in the left atrium of the established Pentaray catheter to the newer Octaray catheter.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Compared with conventional point by point mapping, the use of a multipolar high density Pentaray catheter (Biosense Webster, Diamond Bar, CA, USA) has been found to produce more rapid, accurate maps. This catheter has 20, 2mm2 electrodes. Newer, high density mapping catheters have also been introduced, capable of collecting detailed maps rapidly. Such catheters include the Orion catheter (Boston Scientific, Marlborough, MA, USA) which has 64, 0.4mm2 electrodes and has been shown to be safe and effective in real world usage, and the HD Grid (Abbott Cardiovascular, Lake Forest, IL, USA) which has 16, 1mm electrodes and has been shown to be associated with shorter procedure and fluoroscopy times and better success rates than conventional circular mapping catheters when used for AF ablation.

Of the above high density catheters, the Pentaray is integrated into the Carto3 system. An advantage of this platform for mapping is the ability to use the Tissue Proximity Indicator (TPI) Filter to reduce the number of points collected without contact and improve the accuracy of the subsequent voltage map.

A novel multipolar catheter, iterating on the previous Pentaray catheter is now being introduced: Octaray. This has 48, 0.9mm2 electrodes arranged on 8 splines. In preclinical studies, Octaray has been found to be collect maps faster, at higher density and with greater accuracy for conduction gaps than the Pentaray. The new catheter has been used safely in clinical cases.

Methods This is a randomised, prospective, single centre, interventional study, Thirty patients listed for redo AF ablation procedures on clinical grounds will be included in the study. Procedures will be under conscious sedation or general anaesthetic as per the preference of the operator, as will the mode of transeptal access and sheaths used to deliver the mapping catheter to the left atrium.

At the start of the case, two consecutive LA maps will be taken by the same operator using the Pentaray and Octaray catheters. In both cases, throughout the study the same catheter types will be used. For the Pentaray catheter, this will be the standard 4-4-4 spaced version. The Octaray for the study will be the larger, 20mm spline version, with the 3-3-3-3-3 spacing.

To minimise any learning effect from repeated map collections in the same chamber, patients will be randomly assigned, using block randomisation, as to whether their first LA map will be collected using the Octaray or Pentaray. The randomised group the patient is in will be kept in a sealed envelope which will only be opened on the day of the procedure. All maps will be respiratory gated. The same sheath will be used for both catheters. For the study protocol, maps will be taken with first one mapping catheter and then the alternative. The rhythm during collection will be the same for both maps. Ideally patients would be in sinus rhythm, with maps collected with coronary sinus pacing. If there were challenges maintaining sinus rhythm during mapping, maps can be taken in AF (though not a mixture of rhythms). The setup in terms of window of interest and references will also be identical. The map detail level will be left at 16 for all maps. The map maximum point density will be left as nominal. The fill and colour thresholds will be kept unchanged at nominal values. No ablation will be permitted between the two maps being collected. When the second map is being collected using the alternative catheter, this will be a new map and not a remap and the prior map will be hidden from the operator.

In order to control for any matrix collected by the initial catheter in taking the first map, a completely new study will be used for the second map.

TPI will be on for the entire collection period for both maps. The time when map collection was started, as well as the fluoroscopy time at that point will be noted. These values will also be noted at the end of the map collection. The aim of map collection will be to get entire coverage of the geometry with voltage data. Where this was not possible will be noted. The time for the catheter to start collecting voltage data will also be recorded, to judge the delay in TPI filter accepted points for the two catheters.

LA Map volumes will be collected from Carto3. The pulmonary veins and any left ventricle inadvertently collected will be removed from the geometries to allow quantitative assessment.

Once the mapping phase has been completed, the operator would complete the procedure as to their usual practice.

There will be no follow up needed for the study. Any acute complications will be noted - acute in this case being defined as complications occurring up to 30 days post-procedure.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Atrial Fibrillation

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

CROSSOVER

Crossover from one mapping catheter to the other with randomisation as to which catheter is used first
Primary Study Purpose

OTHER

Blinding Strategy

DOUBLE

Participants Outcome Assessors
The patient will not be aware which mapping catheter they are randomised to have used in their case first.

The data will be processed for analysis blinded to the catheter used to collect the map

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Pentaray

Initial map collected with Pentaray

Group Type ACTIVE_COMPARATOR

Left atrial mapping

Intervention Type OTHER

Creation of a left atrial voltage map

Octaray

Initial map collected with Octaray

Group Type ACTIVE_COMPARATOR

Left atrial mapping

Intervention Type OTHER

Creation of a left atrial voltage map

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Left atrial mapping

Creation of a left atrial voltage map

Intervention Type OTHER

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

Patients \>18 years listed for redo AF ablation on clinical grounds GA or LA/sedation cases

Exclusion Criteria

Age \<18 years Pregnancy Unable or unwilling to consent Mechanical mitral valve Replacement Enrolled in another clinical study that could confound the results of this study (note: patients enrolled in complementary study are eligible for enrolment)
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Biosense Webster, Inc.

INDUSTRY

Sponsor Role collaborator

University Hospital Southampton NHS Foundation Trust

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Principal Investigators

Learn about the lead researchers overseeing the trial and their institutional affiliations.

Waqas Ullah

Role: PRINCIPAL_INVESTIGATOR

University Hospital Southampton NHS Foundation Trust

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Waqas Ullah

Role: CONTACT

+442381208128

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

RHM CAR0638

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

The TRAMPOLINE VT Study
NCT05152784 COMPLETED NA