An Evaluation of End-Expiratory Lung Volume and Pulmonary Mechanics With Different PEEP Levels in Mechanical Ventilation in ARDS Patients
NCT ID: NCT05993780
Last Updated: 2023-08-15
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
COMPLETED
NA
14 participants
INTERVENTIONAL
2021-08-02
2021-08-26
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
14 adult ARDS patients undergoing invasive mechanical ventilation were included in the study. According to the Berlin Criteria, There were two mild, seven moderates, and five severe ARDS patients. FRC and EELV with decreased PEEP titration estimates (5 cmH2O) were measured by the multiple nitrogen wash-out/washin technique. Gain and compliance values were measured over the dynamic pressure-volume curves created by the intracheal pressure sensor.
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
The Impact of Low Versus High Positive End-expiratory Pressure on Diaphragm Function, Ventilation Efficiency, and Lung Mechanics
NCT07188038
Non-Invasive Positive Pressure Ventilation and Adult Respiratory Distress Syndrome (ARDS)
NCT00644930
Effect of EIT-guided PEEP On Clinical Outcomes in ARDS Patients: a Randomized Controlled Trial
NCT06990477
Feasabilty and Physiological Effects of a Ventilation Strategy Combining PEEP and Tidal Volume Titration According to Inspiratory and Expiratory Transpulmonary Pressures in ARDS Patients.
NCT05337059
Effects of End-expiratory Positive Pressure Optimization in Intubated Patients With Healthy Lung or Acute Respiratory Distress Syndrome
NCT04503876
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
Patients included in the study were connected to a CARESCAPE R860 (GE Healthcare) mechanical ventilator. Rocuronium bromide was administered intravenously to eliminate the spontaneous respiratory effort and opioids for sedation. Tidal volume was adjusted as 6 ml/kg according to the estimated body weight; the respiratory rate was adjusted to ensure normocarbia in blood gas analysis; FiO2 was adjusted as PaO2 55 to 80 mmHg; end-inspiratory pause was adjusted to 20%, and inspiratory/expiratory ratio was adjusted as 1:2.
The ECOV-X (GE Healthcare) module was attached to the ventilator for gas measurements and allowed to warm up. A spirometer kit was inserted between the Y-piece in the ventilator circuit and the bacterial/viral filter with heat and moisture-retaining properties. An intratracheal pressure sensor was inserted to measure pressure levels independent of circuit and tube resistance and to evaluate them on the SpiroDynamics (GE Healthcare) application. EELV was measured with the ECOV-X (GE Healthcare) module using a modified NMBW technique with the change in FiO2. EELV was calculated using VO2 (oxygen consumption) and VCO2 (carbon dioxide production). After all the connections were completed, the VO2 and VCO2 values of the patients were measured. The PEEP titration procedure called Lung INview (GE Healthcare) was initiated in patients whose values stabilized within 30 min. Before the measurement, a recruitment maneuver was performed for 30-40 s at a PEEP level of 20 cmH2O. At four different PEEP levels of 15, 10, 5, and 0 cmH2O, a decreasing PEEP trial was performed, and the measurement results were recorded.
For the same PEEP levels, the shunt fraction decreases when a decreasing PEEP maneuver is used instead of an increasing PEEP maneuver. This suggests that the relationship between optimal PEEP and maximum compliance may be more accurate. Therefore, decreasing PEEP trials was preferred as the study protocol.
The measurement time at each PEEP level was chosen as 10 minutes. At the end of the measurement, static compliance was measured by applying an end-inspiratory pause. Tidal volume, peak, and driving pressure were recorded at each step. Respiratory system elastance was calculated using the equation by Henderson et al.(respiratory system elastance = driving pressure/tidal volume). The static strain was calculated using the equation using the tidal volume at the relevant PEEP value (static strain =VPEEP/FRC). The pressure-volume curve generated by the intratracheal pressure sensor at each PEEP level was evaluated using the SpiroDynamics application. A dynamic compliance curve was generated during the analysis, and volume changes in this curve were determined at each PEEP level. The difference in EELV at two different PEEP levels during a descending PEEP trial was calculated as ∆EELV, and the difference between ∆EELV and the volume derived from the pressure-volume curve was calculated as "volume gain" (gain = ∆EELV - volume derived from the curve). The estimated lung volume recovered was calculated using the formula ∆EELV - (∆PEEP x Compliance PEEPlow) and compared with the volume gain. The efficiency of the volume gains concept as an indicator of the volume gained by alveolar recruitment and its role in personalized PEEP titration was evaluated.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
ARDS patient
14 patients with ARDS were included in the study. It was planned as a single group.
No drugs or biologial agents were used in our trial
Before the measurement, a recruitment maneuver was performed for 30-40 s at a PEEP level of 20 cmH2O. At four different PEEP levels of 15, 10, 5, and 0 cmH2O, a decreasing PEEP trial was performed, and the measurement results were recorded.The measurement time at each PEEP level was chosen as 10 minutes. At the end of the measurement, static compliance was measured by applying an end-inspiratory pause. Respiratory system elastance,static strain volume gain was calculated.The estimated lung volume recovered was calculated using the formula ∆EELV - (∆PEEP x Compliance PEEPlow) and compared with the volume gain.
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
No drugs or biologial agents were used in our trial
Before the measurement, a recruitment maneuver was performed for 30-40 s at a PEEP level of 20 cmH2O. At four different PEEP levels of 15, 10, 5, and 0 cmH2O, a decreasing PEEP trial was performed, and the measurement results were recorded.The measurement time at each PEEP level was chosen as 10 minutes. At the end of the measurement, static compliance was measured by applying an end-inspiratory pause. Respiratory system elastance,static strain volume gain was calculated.The estimated lung volume recovered was calculated using the formula ∆EELV - (∆PEEP x Compliance PEEPlow) and compared with the volume gain.
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
* Berlin definition criteria: (1) presence of acute hypoxemic respiratory failure, (2) onset within 7 days of insult, or or new (within 7 days) or worsening respiratory symptoms; (3) bilateral opacities on chest x-ray or CT not fully explained by effusions, lobar or lung collapse, or nodules; and (4) cardiac failure not primary cause of acute respiratory failure.
Exclusion Criteria
18 Years
ALL
No
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Pamukkale University
OTHER
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Selvinaz Yüksel Tanrıverdi
Specialist, Department of Anesthesiology and Reanimation, MD
Locations
Explore where the study is taking place and check the recruitment status at each participating site.
Pamukkale University
Denizli, , Turkey (Türkiye)
Countries
Review the countries where the study has at least one active or historical site.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
PamukkaleUSyuksel-001
Identifier Type: -
Identifier Source: org_study_id
More Related Trials