Safety and Performance Study for Arterial Large Hole Vascular Closure Device
NCT ID: NCT05951634
Last Updated: 2023-07-19
Study Results
The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.
Basic Information
Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.
UNKNOWN
NA
120 participants
INTERVENTIONAL
2023-08-31
2025-09-30
Brief Summary
Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.
Note, for reference purposes, it is expected arteriotomies created with 14 to 22 F sheaths will create an arteriotomy in the range of 16 - 26 F (being the outer diameter of these sheaths).
Related Clinical Trials
Explore similar clinical trials based on study characteristics and research focus.
Safety and Performance Study of Large Hole Vascular Closure Device - France
NCT05323877
PerQseal® Clinical Study
NCT05653336
Safety and Performance Study of Large Hole Vascular Closure Device FIV
NCT03423602
Safety and Performance Study of Large Hole Vascular Closure Device - FRONTIER V Study
NCT04799769
Safety and Performance Study of Large Hole Vascular Closure Device
NCT01943344
Detailed Description
Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.
All subjects shall have a pre-discharge, 30-Days ± 7-Days and 180-Days ± 30-Days follow-up assessment. All safety data from the study will be assessed by the Data Safety Monitoring Committee on a continuous basis.
Conditions
See the medical conditions and disease areas that this research is targeting or investigating.
Study Design
Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.
NA
SINGLE_GROUP
TREATMENT
NONE
Study Groups
Review each arm or cohort in the study, along with the interventions and objectives associated with them.
Investigational Device Arm (PerQseal Elite)
Large hole percutaneous arterial closure device - PerQseal Elite
PerQseal ELITE
Percutaneous ELITE Arterial Closure Device
The term PerQseal Elite used singularly refers to the closure system comprising the closure device and Introducer. These individually are referred to as: "PerQseal Elite VCD" or "PerQseal Elite closure device" and/or "PerQseal Elite Introducer".
Interventions
Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.
PerQseal ELITE
Percutaneous ELITE Arterial Closure Device
The term PerQseal Elite used singularly refers to the closure system comprising the closure device and Introducer. These individually are referred to as: "PerQseal Elite VCD" or "PerQseal Elite closure device" and/or "PerQseal Elite Introducer".
Eligibility Criteria
Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.
Inclusion Criteria
2. Clinically indicated for a percutaneous arterial interventional catheter-based procedure, e.g., transcatheter aortic valve replacement/implantation (TAVR/TAVI) or endovascular abdominal aortic aneurysm repair (EVAR), or thoracic endovascular aortic aneurysm repair (TEVAR), or use of a circulatory assist device or extracorporeal oxygenation using a common femoral arteriotomy created by a 14 to 22F sheath (arteriotomy up to 26F).
3. Subject is willing and able to provide appropriate study-specific informed consent, follow protocol procedures, and comply with follow-up visit requirements.
4. Females who are not pregnant or lactating and not planning to become pregnant for the duration of the study.
Exclusion Criteria
2. Known bleeding diathesis, definite or potential coagulopathy, platelet count \< 100,000/µl or subjects on long term anticoagulants with an INR \> 2 within 12 hours prior to index procedure,
3. Significant anaemia (example: haemoglobin \< 9 g/dL or haematocrit \< 27%), within 24 hours prior to index procedure,
4. Known type II heparin-induced thrombocytopenia,
5. Documented left ventricular ejection fraction \< 20%,
6. Ipsilateral or contralateral lower extremity amputation,
7. Previous groin surgery within the region of the ipsilateral access,
8. Claudication (Rutherford category 3 or greater), documented untreated iliac or common femoral artery diameter stenosis \> 50% or previous bypass surgery/stent placement in the common femoral artery of target leg,
9. Known existing nerve damage in the target leg,
10. Renal insufficiency (Glomerular Filtration Rate ≤ 30 ml/min or baseline serum creatinine \> 2.5 mg/dl) or on renal replacement therapy,
11. Known allergy to any of the materials used in the PerQseal Elite device (refer to Investigator's Brochure),
12. Subject is unsuitable for surgical repair of the target leg access site,
13. Subject has undergone a percutaneous procedure greater than 8F sheath in the target leg, within the 90-days prior to index procedure,
14. Subject has undergone a percutaneous procedure of 8F sheath or less using an absorbable intravascular closure device for haemostasis, in the target leg, within the 90-days prior to index procedure,
15. Subject has undergone a percutaneous procedure of 8F sheath or less using a suture mediated closure device or manual/mechanical pressure for haemostasis in the target leg, within the 30-days prior to index procedure,
16. Evidence of marked tortuosity of the femoral or external iliac arteries in the target leg, based on pre-primary procedure CT angiography,
17. Evidence of arterial diameter stenosis \> 20% within 15 mm proximal or distal to arteriotomy site based on pre-primary procedure CT angiography,
18. Evidence of anterior wall calcification of the target common femoral artery (other than small, diffuse deposits which in the opinion of the investigator will not impede the vascular closure procedure) within 15 mm proximal or distal to arteriotomy site based on pre-primary procedure CT angiography,
19. Target femoral artery diameter is less than 7 mm, based on pre-primary procedure CT angiography,
20. Further planned endovascular/catheter-based procedure in the target leg in the 30-days following the index procedure,
21. Subject is enrolled in another investigational medical device or drug study,
22. Subject has been previously enrolled in this clinical study,
23. Current COVID-19 infection (with or without symptoms), recent positive test for COVID-19 within two weeks, or recent exposure to a person with COVID-19 infection within two weeks.
24. Initial common femoral arterial access achieved with manual palpation or blind arterial stick access, without use of an image guided approach (ultrasound or angiography),
25. Difficult dilation during initial target femoral artery access (e.g., that damages or kinks dilators) while step-dilating up to the large-bore device,
26. During arterial puncture, the target femoral artery suspected to have experienced a posterior arterial wall needle puncture or underwent \> one needle puncture during the primary procedure, with a needle larger than a micropuncture needle (\> 21 gauge or \> 0.819 mm diameter). (Note: not an exclusion if micropuncture technique under ultrasound guidance used for femoral artery access \[Ref. 19, 20\]),
27. Subject has a tissue tract (i.e., estimated distance from skin entry point to arterial anterior surface at arteriotomy) expected to be greater than 8 cm,
28. Significant blood loss requiring transfusion of blood products during primary procedure or within 30-days prior to index procedure,
29. Activated clotting time (ACT) \> 300 seconds immediately prior to sheath removal or if ACT measurements are expected to be \> 300 seconds for more than 24 hours after index procedure,
30. Target puncture site is in a vascular graft,
31. Target arteriotomy greater than 26F,
32. Target arteriotomy in the profunda femoris or superficial femoral artery or is in common femoral artery, but within 15 mm proximal of the bifurcation of the superficial femoral/ profunda femoris artery, (apex of bifurcation overlying the femoral head),
33. Target arteriotomy located at the level or above the inferior epigastric artery and/or beneath or above the inguinal ligament based on bony/arterial landmarks (above femoral head on A-P projection),
34. Subjects with an acute haematoma \> 4 cm diameter, arteriovenous fistula, pseudoaneurysm or intraluminal thrombosis at the target access site identified intra-procedurally,
35. Evidence of bleeding around the primary procedure sheath (VARC type 1/BARC type 2 or higher),
36. Intra-procedural angiographic evidence of arterial laceration, dissection or stenosis within the femoral artery that would preclude use of the PerQseal Elite device,
37. Uncontrolled hypertension (systolic blood pressure \> 180 mmHg or diastolic blood pressure \> 110 mmHg) at the time of planned vascular closure,
38. Systolic blood pressure \< 90 mmHg at the time of planned vascular closure. \*May not be known until after the patient has given informed consent and the procedure has started. In this event, the PerQseal Elite should not be used and the patient should be considered excluded from the study and intention to treat analysis.
Note: The use of a secondary closure device in the same leg is prohibited during this study. A note to this effect should be entered into the patient's medical records.
\-
19 Years
ALL
Yes
Sponsors
Meet the organizations funding or collaborating on the study and learn about their roles.
Vivasure Medical Limited
INDUSTRY
Responsible Party
Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.
Central Contacts
Reach out to these primary contacts for questions about participation or study logistics.
Other Identifiers
Review additional registry numbers or institutional identifiers associated with this trial.
P935-00
Identifier Type: -
Identifier Source: org_study_id
More Related Trials
Additional clinical trials that may be relevant based on similarity analysis.