Evaluating the Use of the CapBuster System for the Crossing of CTO's in Coronary Arteries

NCT ID: NCT05733481

Last Updated: 2023-02-21

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

UNKNOWN

Clinical Phase

NA

Total Enrollment

26 participants

Study Classification

INTERVENTIONAL

Study Start Date

2023-04-01

Study Completion Date

2024-12-31

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Evaluate the safety and effectiveness of the CapBuster System medical device in crossing de novo or restenotic chronic total occlusions in coronary arteries

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

Primary Efficacy Endpoints:

Successful crossing of the targeted chronic total occlusion, defined as angiography confirmed guidewire placement in the true lumen without utilization of a re-entry device.

The effectiveness endpoint is designed to demonstrate successful crossing of the chronic total occlusion in at least 80% of lesions.

Primary Safety Endpoints:

Freedom from CapBuster System related clinically significant perforation, embolization, or dissection, defined as perforations or embolization that require intervention and flow-limiting (type C, D, E) dissections.

Secondary Endpoints I. Study procedure success, defined as successful CTO crossing with the absence of in-hospital/outpatient lab significant events and clinically significant perforation, embolization, or dissection not resolved by visual estimate.

II. Evaluation of CTO crossing time. III. Evaluation of total procedural time, fluoroscopic time, and contrast volume.

IV. All CapBuster System related adverse events through 30 days post-procedure. V. Lesion treatment success, defined as ≤ 30% final residual stenosis of the target lesion using commercially available percutaneous treatment modalities.

VI. Freedom from CapBuster System related significant events through 30 days, defined as death or target vessel revascularization that occurred as a result of a CapBuster System related complication or adverse event.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Chronic Total Occlusion of Coronary Artery

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

NA

Intervention Model

SINGLE_GROUP

Primary Study Purpose

TREATMENT

Blinding Strategy

NONE

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Patients with the presence of coronary arterial de novo or restenotic chronic total occlusion.

Successful crossing of the targeted chronic total occlusion, defined as angiography confirmed guidewire placement in the true lumen without utilization of a re-entry device.

Group Type OTHER

CapBuster System Medical Device for the Crossing of Chronic Total Occlusions in Coronary Arteries

Intervention Type DEVICE

The CapBuster System is a medical device intended to facilitate the intraluminal placement of conventional guidewires beyond chronic total occlusions prior to the utilization of interventional devices. The device system, manufactured by Praxis Medical, comprises the CapBuster support catheter and CapBuster penetrating wire which are mated together with a screw thread.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

CapBuster System Medical Device for the Crossing of Chronic Total Occlusions in Coronary Arteries

The CapBuster System is a medical device intended to facilitate the intraluminal placement of conventional guidewires beyond chronic total occlusions prior to the utilization of interventional devices. The device system, manufactured by Praxis Medical, comprises the CapBuster support catheter and CapBuster penetrating wire which are mated together with a screw thread.

Intervention Type DEVICE

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

CapBuster

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

1. Males \> 18 years of age and Female patients of non child-bearing potential
2. Clinical diagnosis of coronary arterial disease requiring revascularization as evidenced by Duplex UltraSound, Digital Subtraction Angiography, CT angiography, or MR angiography
3. Subject requires single- or multi-vessel percutaneous coronary intervention (PCI) of de novo or restenotic target lesion (including in-stent restenotic lesions).
4. Subject's lesion(s) is (are) amenable to stent treatment with currently available CE or FDA-approved stents.
5. Presence of coronary arterial de novo or restenotic chronic total occlusion (100% stenosis), with TIMI 0 flow, confirmed by angiography. Vessel distal to the occlusion(s) must be visualized per collateral or retrograde flow. A maximum of 1 target occlusions can be treated per patient. Target occlusion(s) can be in-stent restenosis
6. Target vessel(s) must be ≥ 2.5 mm and ≤ 3.25 mm in diameter proximal to the target occlusion(s) by visual estimate
7. In the opinion of the investigator, life expectancy of \> 1 year
8. Willing and able to sign the informed consent form

Exclusion Criteria

1. Target occlusion is within a bypass graft
2. acute coronary syndrome with ST elevation,
3. cardiogenic shock or out of hospital cardiac arrest
4. Subject has signs or symptoms of systemic infection/sepsis (temperature ≥38.0o Celsius and WBC ≥12,000 cells/uL). If subject has localized infection, including cellulitis or osteomyelitis, or infection is adequately treated and controlled, per investigator discretion, patient may be enrolled.
5. Known or suspected myocardial infarction or stroke within previous 30 days
6. Currently participating in another investigational drug or device study
7. Female patients of child-bearing potential.
8. Evidence of STEMI within 72 hours of the intended treatment on infarct related or non-infarct related artery.
9. Cardiogenic shock on presentation or during current hospitalization.
10. Known allergies or contraindication to: contrast materials, antiplatelet therapy, aspirin, clopidogrel (Plavix) and ticlopidine (Ticlid), heparin, bivalirudin, stainless steel, or contrast agent (which cannot be adequately premedicated).
11. Subject is currently participating in an investigational drug or device study that has not completed the primary endpoint or that clinically interferes with the current study endpoints. (Note: Trials requiring extended follow-up for products that were investigational, but have since become commercially available, are not considered investigational trials).
12. Stroke or transient ischemic attack within the prior 3 months.
13. Any target vessel that has evidence of excessive thrombus (e.g. requires target vessel thrombectomy).
14. Any target vessel that has evidence of excessive tortuousity (greater than 60 degree angle) that makes it unsuitable for proper stent delivery and deployment,
15. Any target lesion that requires treatment with a device other than percutaneous transluminal coronary angioplasty (PTCA) prior to stent placement (e.g. but not limited to, directional coronary atherectomy, excimer laser, rotational atherectomy, etc.).
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

No

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

Praxis Medical Devices Ltd

INDUSTRY

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Responsibility Role SPONSOR

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

CAP002

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Carotid With Bivalirudin Angioplasty
NCT00812383 COMPLETED PHASE2