The Effects of Different Storage Conditions on Removable Retainers

NCT ID: NCT05854953

Last Updated: 2023-08-30

Study Results

Results pending

The study team has not published outcome measurements, participant flow, or safety data for this trial yet. Check back later for updates.

Basic Information

Get a concise snapshot of the trial, including recruitment status, study phase, enrollment targets, and key timeline milestones.

Recruitment Status

UNKNOWN

Clinical Phase

NA

Total Enrollment

24 participants

Study Classification

INTERVENTIONAL

Study Start Date

2023-05-10

Study Completion Date

2024-09-30

Brief Summary

Review the sponsor-provided synopsis that highlights what the study is about and why it is being conducted.

Orthodontic removable retainers are appliances that hold the position of the upper and lower teeth after fixed braces treatment and they can be removed from a patient's mouth. Basically, there are 2 types of removable retainers; Hawley retainer and vacuum-formed retainer.

Hawley retainer is made of an acrylic resin plate that covers the palate for the upper jaw and the back of the arch facing the tongue for the lower jaw. It has thin stainless-steel wires incorporated to fit the first molars and the six front teeth as retention.

Vacuum-formed retainer (VFR) is a clear or transparent plastic retainer. It covers the teeth completely and a small part of the gum.

The investigators' interest is to determine whether the storage conditions will affect the amount of bacteria, appearance and strength of removable retainers. Primarily, the amount of bacteria that sticks to the retainers may cause overall dental and oral health effects such as mouth odour, dental caries and gum problems. The investigators would also like to assess the oral health-related quality of life (OHRQoL) of participants after storing retainers in different storage conditions by answering a questionnaire.

Detailed Description

Dive into the extended narrative that explains the scientific background, objectives, and procedures in greater depth.

RATIONALE OF THE STUDY

A non-bias clinical study is required to facilitate the best recommendation to care for the orthodontic retainers. This may prevent the risk of further harms to the oral condition and increase the longevity of the retainers. In turn, this would improve the OHRQoL of orthodontic patients and potentially save the cost of retainer replacements. Therefore, the findings may help to provide evidence-based guidelines for the storage method of removable retainers.

Primary Objective

1. To compare the microbial colony counts of removable retainers in wet and dry storage conditions.

Secondary Objectives
2. To compare the surface roughness of removable retainer materials in wet and dry storage conditions.
3. To compare the colour stability of removable retainer materials in wet and dry storage conditions.
4. To compare the compressive strength of removable retainer materials in wet and dry storage conditions.
5. To evaluate OHRQoL of participants storing their removable retainers in dry and wet conditions.

SAMPLE SIZE CALCULATION

Sample size calculation was done using G\* Power 3.1. The total sample size is 18, for an alpha error equivalent to 0.05, a study power equivalent to 80%, a two-sided test type, and an effect size of 1.316 (Farhadian et al., 2016). Considering a potential dropout of 30%, therefore 24 participants will be recruited.

METHODOLOGY

Participants who fit the inclusion and exclusion criteria will be invited to enrol at the Orthodontic Postgraduate Clinic, Faculty of Dentistry, Universiti Malaya. Once the participants consent to take part in this study, an explanation will be given in detail of the procedure of the research with the aid of the flowchart diagram. The participants will also be given a participant information sheet. An appointment for the removal of fixed braces will be scheduled.

All participants will be required to draw lots from the sealed envelope which has been randomised by the consultant orthodontist to know their first retainer storage condition. The investigator will have to check the group allocation with the consultant orthodontist.

On the first appointment day, the removal of braces will be done according to the standard protocol. Then, four sets of impressions will be taken to construct the models and retainers. The participants will be issued with their regular upper and lower retainers, a new toothbrush and a retainer box. The participants will be instructed to store their retainers in a dry retainer box or in a glass of clean water the entire time when not in use. Other home care instructions include: 1) wear the retainers part-time (8-12 hours daily), 2) clean the retainers with a soft-bristled toothbrush and rinse thoroughly, and 3) no additional cleaning solutions and tablets are allowed. The participants will need to answer a self-administered questionnaire 1 week later to assess their personal judgment on the removable retainers.

The participants will be called 3 months later for review (T1). During this visit, the standard retainers will be taken by the investigator for analysis. The interventional retainers will be issued to the participants with an instruction to exchange the storage method from dry to wet conditions and from wet to dry conditions. The same home care instructions will be advised. The participants will receive a new toothbrush to clean their appliance and a new retainer box to keep their retainers. The participants will need to answer a questionnaire sheet again.

The participants will be called 6 months later for review (T2). The first interventional retainers will be taken by the investigator for the final analysis. The second interventional retainers will be issued to the participants and they will be instructed to continue caring for their retainers. All participants will be required to answer a questionnaire sheet for the final time.

Three different sets of the newly constructed Hawley and vacuum-formed retainers will be tested for microbial analysis, physical and mechanical properties as baseline characteristics for comparisons.

STATISTICAL ANALYSIS

Results obtained will be computed using SPSS Statistics for Windows, Version 26.0. Statistical significance will be set at p \< 0.05.

The manipulating variables are the types of storage conditions, which are dry and wet with α = 5% = 0.05 and confidence interval (CI) of 95%. Test of normality will be done using the Shapiro-Wilk test for each of the dependent variables (outcomes).

i. Mann-Whitney U-Test will be applied to compare the dependent variables of the two groups (Hawley retainers and VFRs) at baseline, T1 and T2.

ii. Wilcoxon Signed Rank test will be used to compare the storage conditions of the two groups (Hawley retainers and VFRs) at baseline, T1 and T2.

iii. Kruskal Wallis will be carried out to investigate the interaction between the two samples and the storage conditions.

iv. If the data is normally distributed, then the equivalent parametric analyses (paired t-test and independent t-test) will be performed.

Conditions

See the medical conditions and disease areas that this research is targeting or investigating.

Orthodontic Appliance Complication

Study Design

Understand how the trial is structured, including allocation methods, masking strategies, primary purpose, and other design elements.

Allocation Method

RANDOMIZED

Intervention Model

CROSSOVER

Baseline characteristics - newly constructed Hawley and vacuum-formed retainers will be tested for microbial analysis, phyiscal and mechanical properties as comparisons with other groups

Group 1 - Participants with Hawley retainers will begin storing their retainers in dry condition, 3 months later, they will change the storage to wet condition.

Group 2 - Participants with Hawley retainers will begin storing their retainers in wet condition, 3 months later, they will change the storage to dry condition.

Group 3 - Participants with vacuum-formed retainers will begin storing their retainers in dry condition, 3 months later, they will change the storage to wet condition.

Group 4 - Participants with vacuum-formed retainers will begin storing their retainers in wet condition, 3 months later, they will change the storage to dry condition.
Primary Study Purpose

SCREENING

Blinding Strategy

SINGLE

Investigators
Investigator will be masked with the randomization sequance \& allocation.

Study Groups

Review each arm or cohort in the study, along with the interventions and objectives associated with them.

Hawley retainers in dry storage condition

Acrylic retainers to be stored in a dry retainer box the entire time when not in use.

Group Type EXPERIMENTAL

Hawley retainers in dry storage condition

Intervention Type DEVICE

Three months later, an exchange of storage methods from dry to wet conditions will take place.

Hawley retainers in wet storage condition

Acrylic retainers to be stored in a glass of clean tap water the entire time when not in use.

Group Type EXPERIMENTAL

Hawley retainers in wet storage condition

Intervention Type DEVICE

Three months later, an exchange of storage methods from wet to dry conditions will take place.

Vacuum-formed retainers in dry storage condition

Thermoplastic retainers to be stored in a dry retainer box the entire time when not in use.

Group Type EXPERIMENTAL

VFRs in dry storage condition

Intervention Type DEVICE

Three months later, an exchange of storage methods from dry to wet conditions will take place.

Vacuum-formed retainers in wet storage condition

Thermoplastic retainers to be stored in a glass of clean tap water the entire time when not in use.

Group Type EXPERIMENTAL

VFRs in wet storage condition

Intervention Type DEVICE

Three months later, an exchange of storage methods from wet to dry conditions will take place.

Baseline characteristics

Newly constructed Hawley retainers and VFRs will be labeled as baseline samples.

Group Type ACTIVE_COMPARATOR

Baseline characteristics

Intervention Type DEVICE

Hawley retainers and VFRs that are newly constructed will be used as baseline samples. The samples will be taken for microbial, physical and mechanical tests.

Interventions

Learn about the drugs, procedures, or behavioral strategies being tested and how they are applied within this trial.

Hawley retainers in dry storage condition

Three months later, an exchange of storage methods from dry to wet conditions will take place.

Intervention Type DEVICE

Hawley retainers in wet storage condition

Three months later, an exchange of storage methods from wet to dry conditions will take place.

Intervention Type DEVICE

VFRs in dry storage condition

Three months later, an exchange of storage methods from dry to wet conditions will take place.

Intervention Type DEVICE

VFRs in wet storage condition

Three months later, an exchange of storage methods from wet to dry conditions will take place.

Intervention Type DEVICE

Baseline characteristics

Hawley retainers and VFRs that are newly constructed will be used as baseline samples. The samples will be taken for microbial, physical and mechanical tests.

Intervention Type DEVICE

Other Intervention Names

Discover alternative or legacy names that may be used to describe the listed interventions across different sources.

Acrylic retainers Acrylic retainers Thermoplastic clear retainers Thermoplastic clear retainers

Eligibility Criteria

Check the participation requirements, including inclusion and exclusion rules, age limits, and whether healthy volunteers are accepted.

Inclusion Criteria

* Patients aged 18 years and above
* Fixed appliance treatment on both the upper and lower arches
* Ready for debond
* Planned for either Hawley retainers or VFRs for retention
* Fit and healthy patients without systemic disease
* Non-smoking patients

Exclusion Criteria

* Sectional fixed appliance treatment or fixed appliance treatment on single arch only
* Planned for double retention with bonded retainers
* Systemic disease that may affect salivary flow
* Smoking patients
Minimum Eligible Age

18 Years

Eligible Sex

ALL

Accepts Healthy Volunteers

Yes

Sponsors

Meet the organizations funding or collaborating on the study and learn about their roles.

University of Malaya

OTHER

Sponsor Role lead

Responsible Party

Identify the individual or organization who holds primary responsibility for the study information submitted to regulators.

Dr Wan Nurazreena Wan Hassan

Associate Professor, Department of Paediatric Dentistry & Orthodontics, Faculty of Dentistry

Responsibility Role PRINCIPAL_INVESTIGATOR

Locations

Explore where the study is taking place and check the recruitment status at each participating site.

Orthodontic Postgraduate Clinic, Faculty of Dentistry

Kuala Lumpur, Kuala Lumpur, Malaysia

Site Status RECRUITING

Countries

Review the countries where the study has at least one active or historical site.

Malaysia

Central Contacts

Reach out to these primary contacts for questions about participation or study logistics.

Amira Farhana Kairul Annuar

Role: CONTACT

+0133936354

Wan Nurazreena Wan Hassan

Role: CONTACT

+60379674802 ext. 2476

Facility Contacts

Find local site contact details for specific facilities participating in the trial.

Amira Farhana Kairul Annuar

Role: primary

+60133936254

Wan Nurazreena Wan Hassan

Role: backup

+60379674802

References

Explore related publications, articles, or registry entries linked to this study.

Ahn HW, Ha HR, Lim HN, Choi S. Effects of aging procedures on the molecular, biochemical, morphological, and mechanical properties of vacuum-formed retainers. J Mech Behav Biomed Mater. 2015 Nov;51:356-66. doi: 10.1016/j.jmbbm.2015.07.026. Epub 2015 Aug 3.

Reference Type RESULT
PMID: 26282078 (View on PubMed)

Ahn HW, Kim KA, Kim SH. A new type of clear orthodontic retainer incorporating multi-layer hybrid materials. Korean J Orthod. 2015 Sep;45(5):268-72. doi: 10.4041/kjod.2015.45.5.268. Epub 2015 Sep 23.

Reference Type RESULT
PMID: 26445722 (View on PubMed)

Al Groosh DH, Bozec L, Pratten J, Hunt NP. The influence of surface roughness and surface dynamics on the attachment of Methicillin-Resistant Staphylococcus aureus onto orthodontic retainer materials. Dent Mater J. 2015;34(5):585-94. doi: 10.4012/dmj.2014-045.

Reference Type RESULT
PMID: 26438981 (View on PubMed)

Alassiry AM. Orthodontic Retainers: A Contemporary Overview. J Contemp Dent Pract. 2019 Jul 1;20(7):857-862.

Reference Type RESULT
PMID: 31597809 (View on PubMed)

Chagas AS, Freitas KMS, Cancado RH, Valarelli FP, Canuto LFG, Oliveira RCG, Oliveira RCG. Level of satisfaction in the use of the wraparound Hawley and thermoplastic maxillary retainers. Angle Orthod. 2020 Jan;90(1):63-68. doi: 10.2319/031319-197.1. Epub 2019 Jul 22.

Reference Type RESULT
PMID: 31335161 (View on PubMed)

Fang J, Wang C, Li Y, Zhao Z, Mei L. Comparison of bacterial adhesion to dental materials of polyethylene terephthalate (PET) and polymethyl methacrylate (PMMA) using atomic force microscopy and scanning electron microscopy. Scanning. 2016 Nov;38(6):665-670. doi: 10.1002/sca.21314. Epub 2016 Mar 15.

Reference Type RESULT
PMID: 26991988 (View on PubMed)

Farhadian N, Usefi Mashoof R, Khanizadeh S, Ghaderi E, Farhadian M, Miresmaeili A. Streptococcus mutans counts in patients wearing removable retainers with silver nanoparticles vs those wearing conventional retainers: A randomized clinical trial. Am J Orthod Dentofacial Orthop. 2016 Feb;149(2):155-60. doi: 10.1016/j.ajodo.2015.07.031.

Reference Type RESULT
PMID: 26827971 (View on PubMed)

Kolenbrander PE, Andersen RN, Blehert DS, Egland PG, Foster JS, Palmer RJ Jr. Communication among oral bacteria. Microbiol Mol Biol Rev. 2002 Sep;66(3):486-505, table of contents. doi: 10.1128/MMBR.66.3.486-505.2002.

Reference Type RESULT
PMID: 12209001 (View on PubMed)

Littlewood SJ, Millett DT, Doubleday B, Bearn DR, Worthington HV. Retention procedures for stabilising tooth position after treatment with orthodontic braces. Cochrane Database Syst Rev. 2016 Jan 29;2016(1):CD002283. doi: 10.1002/14651858.CD002283.pub4.

Reference Type RESULT
PMID: 26824885 (View on PubMed)

Marsh PD. Dental plaque as a biofilm and a microbial community - implications for health and disease. BMC Oral Health. 2006 Jun 15;6 Suppl 1(Suppl 1):S14. doi: 10.1186/1472-6831-6-S1-S14.

Reference Type RESULT
PMID: 16934115 (View on PubMed)

Saub R, Locker D, Allison P, Disman M. Cross-cultural adaptation of the Oral Health Impact Profile (OHIP) for the Malaysian adult population. Community Dent Health. 2007 Sep;24(3):166-75.

Reference Type RESULT
PMID: 17958078 (View on PubMed)

Other Identifiers

Review additional registry numbers or institutional identifiers associated with this trial.

S2042680

Identifier Type: -

Identifier Source: org_study_id

More Related Trials

Additional clinical trials that may be relevant based on similarity analysis.

Essix Retainer vs Hawley Retainer
NCT01583933 UNKNOWN PHASE3